Colorado Time Systems QuickStart Pro
From Libre Aquatics Wiki, the free aquatics reference
The QuickStart Pro is a portable LED training display made by
Colorado Time Systems (CTS), the successor to the
QuickStart.1 It runs as a pace clock and lap counter. With CTS timing
equipment plugged into its side it times start reactions, relay exchanges, break-outs, turns and
single-lane swims, and shows each result to the hundredth of a second.1 Its guide dates from
2006, and the CTS catalogue listed it in 2008 under part number QS-PRO.12
By 2011 CTS had dropped it, and its training modes lived on in the
Pace Clock Pro.34
Role in training¶
This section places the QuickStart Pro among CTS training tools; pace clocks in general are covered in the pace clocks overview. Like the QuickStart before it, the Pro reads the same signals a CTS timing system uses at a meet and shows them on a poolside display during practice.1 These are the start signal from a start system, the take-off from a relay judging platform (RJP), touches on a touchpad, and presses of a pushbutton. The QuickStart could only time the interval between two such events. The Pro adds lap counting, split and lane timing, and colour coding that marks a result as good, slow or early.1
Design and hardware¶
The QuickStart Pro is a small desktop unit with a white housing and a row of LED digits. The cover of its guide shows five digits reading 2:53.17, and the guide’s digit test mentions colons between digits three, four and five.1 The digits light in green, yellow or red to grade a result.1
The inputs are banana jacks on the side panel:1
- two touchpad inputs, joined inside the unit, so a second pad at the opposite wall can join it through a CTS SJ-series extension cable with a stackable banana plug
- a relay platform input
- a start system input
- a reset and break-out input for a pushbutton
Any input will accept a pushbutton pressed by a person, but the guide notes that the unit records to 1/100 s and a hand press cannot match that.1
The unit runs from a supplied 15 V DC power brick with a 5-pin DIN plug, or from an internal battery. A full charge lasts at least six hours, and the battery charges whenever the brick is connected.1 The power switch and a Mode switch are on the right side. At switch-on the Mode switch sets brightness, in eight levels repeated across sixteen positions. Once it has been left alone for four seconds, the display shows the firmware revision and the switch then selects the mode. The mode is fixed until the unit is switched off and on again.1
Operation¶
This section groups the modes by what they do. The guide says the unit has fifteen training modes, but its table numbers them 1 to 16: modes 10 to 14 are one single-lane timer set for different lap counts, and mode 16 is a test mode.1 Most modes show their number at start-up and then wait with only the colon and decimal point lit.1
Clock modes¶
| Mode | Function | Inputs |
|---|---|---|
| 1 | Lap counter: counts touchpad hits from zero | Touchpad1 |
| 2 | Pace clock, counting to 59:59.9 in tenths and rolling over | None1 |
| 3 | Pace clock that holds each touchpad hit as a cumulative split | Touchpad1 |
| 4 | Pace clock that restarts at each touchpad hit, showing lap splits | Touchpad1 |
In each, a start signal or a double click on the reset button restarts the count.1
Reaction modes¶
| Mode | Measures | Inputs |
|---|---|---|
| 5 | Relay exchange: incoming touch to outgoing take-off | Touchpad and RJP1 |
| 6 | Start reaction: start signal to the swimmer leaving the block, or the wall in backstroke | Start system and RJP, or touchpad for backstroke1 |
| 7 | Turn speed: hand touch to push-off | Touchpad1 |
| 8 | Break-out: start signal to the coach’s button press as the swimmer surfaces | Start system and pushbutton1 |
| 9 | Start reaction followed by break-out | Start system, RJP or touchpad, and pushbutton1 |
The guide sets fixed windows for these readings. After a start signal the unit records every RJP or touchpad release for two seconds and keeps the last, so a swimmer rocking on the block does not leave an early time.1 Turn speed uses a three-second window after the hand touch.1 Relay and turn results stay up for ten seconds and then clear for the next swimmer. The others stay until a double click or a new start.1 If an expected input never arrives, the display shows Err in red.1
CTS sets the colour thresholds. A start reaction of 0.55–0.74 s shows green, 0.75–2.00 s yellow, and 0.54 s or less red as an early start. A relay exchange of 0.20 s or less shows green and anything slower yellow. An exchange where the outgoing swimmer left before the touch shows red, as a negative time.1
Single-lane timing¶
Modes 10 to 14 time one swimmer over one, two, three or four laps, or, in mode 14, until the coach presses the reset button to arm the finish and the swimmer next touches.1 Each mode can first record a start reaction from the RJP, or from the touchpad in backstroke. Each split then shows as a cumulative time while the clock keeps running.1 With a pad at each end, connected to the two touchpad inputs, the unit times lengths rather than laps.1 In the multi-lap modes the RJP can also catch a relay take-off at each touch except the last, so the unit can time a relay swimmer and grade the exchange.1
Mid-race timing¶
Mode 15 times the middle of a swim, with no start or finish included. The first touchpad hit of a turn starts the clock, and the pad then ignores further touches for three seconds while the swimmer leaves it.1 The clock stops on the next turn’s push-off, compared with the first touch. With one pad that covers one lap and three turns; with a pad at each end, one length and two turns.1
Test mode¶
Mode 16 runs a digit test and then names whichever input it receives: PAd for a touchpad, rJP, StArt or rESET.1
History and successors¶
This section traces the product through CTS’s documents, which are the only sources found. The
guide is dated 2006.1 CTS’s 2008 catalogue listed the QuickStart Pro among its training
tools, sold either alone or in a one-lane training system, TR-SYS-1. That system paired it
with a 30 in touchpad, an RJPL-2020 relay platform, an
Infinity Start System and a start jumper
cable.2 CTS said elite college and club coaches had contributed to its design.2
The catalogue’s description does not match the guide. It gives five training modes, power from AC or eight D cells, a four-character display with 4 in LEDs, and a size of 12 × 8 × 4 in at 5 lb.2 These are the original QuickStart’s figures.5 The guide, which describes the Pro itself, gives fifteen modes, an internal rechargeable battery and a power brick, and its cover shows five digits.1 This article follows the guide, on the reading that the catalogue copy was carried over from the earlier product.
The same 2008 catalogue sold the Pace Clock Pro, a large 10 in-digit pace and shot clock, with fifteen training modes under the same names.2 Its guide numbers them 1 to 16 exactly as the QuickStart Pro guide does, without the colour bands.4 By 2011 the QuickStart Pro was gone from the catalogue. The one-lane training package, now called Train Right, was built around a Pace Clock Pro instead.36 CTS does not say that one replaced the other; the only evidence is the change in what the package contained.
Compared with the QuickStart¶
The Pro kept the QuickStart’s purpose and its side-panel inputs. Most of the rest is different: fifteen modes chosen with a switch instead of a handful chosen by what was plugged in, a second touchpad input, a rechargeable battery in place of D cells, and colour-coded results.17 The QuickStart article has a side-by-side table.
Specifications¶
| Manufacturer | Colorado Time Systems, Loveland, Colorado |
| Part number | QS-PRO2 |
| Display | Five LED digits; green, yellow and red result coding1 |
| Modes | 15 training modes plus a test mode, numbered 1–161 |
| Timing resolution | 1/100 s1 |
| Inputs | Touchpad (two, linked), relay platform, start system, reset/breakout1 |
| Brightness | Eight levels1 |
| Power | 15 V DC power brick, 5-pin DIN; internal battery, at least 6 hours1 |
| Manual | F896 Rev. 0406 (2006)1 |
The 2008 catalogue’s size and weight figures (12 × 8 × 4 in, 5 lb) are left out of the table because they appear to describe the earlier QuickStart.2
Part numbers and accessories¶
This section lists the parts CTS names with the QuickStart Pro.
QS-PRO, the QuickStart Pro.2TR-SYS-1, the 2008 one-lane system: a 30 in touchpad, anRJPL-2020relay platform, theQS-PRO, anINF-SSMInfinity Start System and anINF-SJ25start jumper cable.2- SJ-series extension cable with a stackable dual banana plug, for a far-end touchpad.1
- 15 V DC power brick, supplied.1
- The RJP caddy, which CTS described as carrying RJPs, a Championship Start System, a QuickStart Pro and cables.2
See also¶
- QuickStart: the predecessor
- Pace clock/shot clock: the CTS clock line whose Pro version carries the same training modes
- Colorado Time Systems RJP: the relay platform it reads, and the Train Right package
- Infinity Start System: the start system in the 2008 training system
- Pace clocks: the pace clocks overview
- Colorado Time Systems: the manufacturer
- Equipment: the equipment reference
References¶
Footnotes¶
-
Colorado Time Systems, QuickStart Pro User Guide (F896 Rev. 0406, 2006). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34 ↩35 ↩36 ↩37 ↩38 ↩39 ↩40 ↩41 ↩42 ↩43 ↩44 ↩45 ↩46 ↩47
-
Colorado Time Systems, Making Time Count: High Impact Visual Display Systems (2008 catalogue), training tools. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10
-
Colorado Time Systems, Complete Timing, Scoring, Training and Display Solutions (2011 catalogue), training tools. ↩ ↩2
-
Colorado Time Systems, Pro Pace Clock and Shot Clock User Guide (F891 Rev. 202008), training modes. ↩ ↩2
-
Colorado Time Systems, QuickStart product page (archived December 2002). ↩
-
Colorado Time Systems, Train Right with Infinity Start System (F957, Rev. 201102). ↩
-
Colorado Time Systems, QuickStart User Guide (F816 Rev. 0104, 2004). ↩
Last updated October 7, 2026.