The QuickStart Pro is a portable LED training display made by Colorado Time Systems (CTS), the successor to the QuickStart.1 It runs as a pace clock and lap counter. With CTS timing equipment plugged into its side it times start reactions, relay exchanges, break-outs, turns and single-lane swims, and shows each result to the hundredth of a second.1 Its guide dates from 2006, and the CTS catalogue listed it in 2008 under part number QS-PRO.12 By 2011 CTS had dropped it, and its training modes lived on in the Pace Clock Pro.34

Role in training

This section places the QuickStart Pro among CTS training tools; pace clocks in general are covered in the pace clocks overview. Like the QuickStart before it, the Pro reads the same signals a CTS timing system uses at a meet and shows them on a poolside display during practice.1 These are the start signal from a start system, the take-off from a relay judging platform (RJP), touches on a touchpad, and presses of a pushbutton. The QuickStart could only time the interval between two such events. The Pro adds lap counting, split and lane timing, and colour coding that marks a result as good, slow or early.1

Design and hardware

The QuickStart Pro is a small desktop unit with a white housing and a row of LED digits. The cover of its guide shows five digits reading 2:53.17, and the guide’s digit test mentions colons between digits three, four and five.1 The digits light in green, yellow or red to grade a result.1

The inputs are banana jacks on the side panel:1

  • two touchpad inputs, joined inside the unit, so a second pad at the opposite wall can join it through a CTS SJ-series extension cable with a stackable banana plug
  • a relay platform input
  • a start system input
  • a reset and break-out input for a pushbutton

Any input will accept a pushbutton pressed by a person, but the guide notes that the unit records to 1/100 s and a hand press cannot match that.1

The unit runs from a supplied 15 V DC power brick with a 5-pin DIN plug, or from an internal battery. A full charge lasts at least six hours, and the battery charges whenever the brick is connected.1 The power switch and a Mode switch are on the right side. At switch-on the Mode switch sets brightness, in eight levels repeated across sixteen positions. Once it has been left alone for four seconds, the display shows the firmware revision and the switch then selects the mode. The mode is fixed until the unit is switched off and on again.1

Operation

This section groups the modes by what they do. The guide says the unit has fifteen training modes, but its table numbers them 1 to 16: modes 10 to 14 are one single-lane timer set for different lap counts, and mode 16 is a test mode.1 Most modes show their number at start-up and then wait with only the colon and decimal point lit.1

Clock modes

ModeFunctionInputs
1Lap counter: counts touchpad hits from zeroTouchpad1
2Pace clock, counting to 59:59.9 in tenths and rolling overNone1
3Pace clock that holds each touchpad hit as a cumulative splitTouchpad1
4Pace clock that restarts at each touchpad hit, showing lap splitsTouchpad1

In each, a start signal or a double click on the reset button restarts the count.1

Reaction modes

ModeMeasuresInputs
5Relay exchange: incoming touch to outgoing take-offTouchpad and RJP1
6Start reaction: start signal to the swimmer leaving the block, or the wall in backstrokeStart system and RJP, or touchpad for backstroke1
7Turn speed: hand touch to push-offTouchpad1
8Break-out: start signal to the coach’s button press as the swimmer surfacesStart system and pushbutton1
9Start reaction followed by break-outStart system, RJP or touchpad, and pushbutton1

The guide sets fixed windows for these readings. After a start signal the unit records every RJP or touchpad release for two seconds and keeps the last, so a swimmer rocking on the block does not leave an early time.1 Turn speed uses a three-second window after the hand touch.1 Relay and turn results stay up for ten seconds and then clear for the next swimmer. The others stay until a double click or a new start.1 If an expected input never arrives, the display shows Err in red.1

CTS sets the colour thresholds. A start reaction of 0.55–0.74 s shows green, 0.75–2.00 s yellow, and 0.54 s or less red as an early start. A relay exchange of 0.20 s or less shows green and anything slower yellow. An exchange where the outgoing swimmer left before the touch shows red, as a negative time.1

Single-lane timing

Modes 10 to 14 time one swimmer over one, two, three or four laps, or, in mode 14, until the coach presses the reset button to arm the finish and the swimmer next touches.1 Each mode can first record a start reaction from the RJP, or from the touchpad in backstroke. Each split then shows as a cumulative time while the clock keeps running.1 With a pad at each end, connected to the two touchpad inputs, the unit times lengths rather than laps.1 In the multi-lap modes the RJP can also catch a relay take-off at each touch except the last, so the unit can time a relay swimmer and grade the exchange.1

Mid-race timing

Mode 15 times the middle of a swim, with no start or finish included. The first touchpad hit of a turn starts the clock, and the pad then ignores further touches for three seconds while the swimmer leaves it.1 The clock stops on the next turn’s push-off, compared with the first touch. With one pad that covers one lap and three turns; with a pad at each end, one length and two turns.1

Test mode

Mode 16 runs a digit test and then names whichever input it receives: PAd for a touchpad, rJP, StArt or rESET.1

History and successors

This section traces the product through CTS’s documents, which are the only sources found. The guide is dated 2006.1 CTS’s 2008 catalogue listed the QuickStart Pro among its training tools, sold either alone or in a one-lane training system, TR-SYS-1. That system paired it with a 30 in touchpad, an RJPL-2020 relay platform, an Infinity Start System and a start jumper cable.2 CTS said elite college and club coaches had contributed to its design.2

The catalogue’s description does not match the guide. It gives five training modes, power from AC or eight D cells, a four-character display with 4 in LEDs, and a size of 12 × 8 × 4 in at 5 lb.2 These are the original QuickStart’s figures.5 The guide, which describes the Pro itself, gives fifteen modes, an internal rechargeable battery and a power brick, and its cover shows five digits.1 This article follows the guide, on the reading that the catalogue copy was carried over from the earlier product.

The same 2008 catalogue sold the Pace Clock Pro, a large 10 in-digit pace and shot clock, with fifteen training modes under the same names.2 Its guide numbers them 1 to 16 exactly as the QuickStart Pro guide does, without the colour bands.4 By 2011 the QuickStart Pro was gone from the catalogue. The one-lane training package, now called Train Right, was built around a Pace Clock Pro instead.36 CTS does not say that one replaced the other; the only evidence is the change in what the package contained.

Compared with the QuickStart

The Pro kept the QuickStart’s purpose and its side-panel inputs. Most of the rest is different: fifteen modes chosen with a switch instead of a handful chosen by what was plugged in, a second touchpad input, a rechargeable battery in place of D cells, and colour-coded results.17 The QuickStart article has a side-by-side table.

Specifications

ManufacturerColorado Time Systems, Loveland, Colorado
Part numberQS-PRO2
DisplayFive LED digits; green, yellow and red result coding1
Modes15 training modes plus a test mode, numbered 1–161
Timing resolution1/100 s1
InputsTouchpad (two, linked), relay platform, start system, reset/breakout1
BrightnessEight levels1
Power15 V DC power brick, 5-pin DIN; internal battery, at least 6 hours1
ManualF896 Rev. 0406 (2006)1

The 2008 catalogue’s size and weight figures (12 × 8 × 4 in, 5 lb) are left out of the table because they appear to describe the earlier QuickStart.2

Part numbers and accessories

This section lists the parts CTS names with the QuickStart Pro.

  • QS-PRO, the QuickStart Pro.2
  • TR-SYS-1, the 2008 one-lane system: a 30 in touchpad, an RJPL-2020 relay platform, the QS-PRO, an INF-SSM Infinity Start System and an INF-SJ25 start jumper cable.2
  • SJ-series extension cable with a stackable dual banana plug, for a far-end touchpad.1
  • 15 V DC power brick, supplied.1
  • The RJP caddy, which CTS described as carrying RJPs, a Championship Start System, a QuickStart Pro and cables.2

See also

References

Footnotes

  1. Colorado Time Systems, QuickStart Pro User Guide (F896 Rev. 0406, 2006). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34 ↩35 ↩36 ↩37 ↩38 ↩39 ↩40 ↩41 ↩42 ↩43 ↩44 ↩45 ↩46 ↩47

  2. Colorado Time Systems, Making Time Count: High Impact Visual Display Systems (2008 catalogue), training tools. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10

  3. Colorado Time Systems, Complete Timing, Scoring, Training and Display Solutions (2011 catalogue), training tools. ↩ ↩2

  4. Colorado Time Systems, Pro Pace Clock and Shot Clock User Guide (F891 Rev. 202008), training modes. ↩ ↩2

  5. Colorado Time Systems, QuickStart product page (archived December 2002). ↩

  6. Colorado Time Systems, Train Right with Infinity Start System (F957, Rev. 201102). ↩

  7. Colorado Time Systems, QuickStart User Guide (F816 Rev. 0104, 2004). ↩

Last updated October 7, 2026.