The MC8 is the cable that ALGE-Timing sells for wiring the finish push buttons of an eight-lane semi-automatic swimming system to a Timy timer. It runs along the finish end of the pool with banana sockets for one 023-02 button per lane, and it ends in a 25-pin D-sub plug.12 ALGE’s 2013 catalogue names it MC8-SWIM; the current name is MC8-S2.31

See the deck cabling overview for the shared background on lane wiring, and the semi-automatic timing overview for how button finishes are judged.

Role in the timing system

In a semi-automatic system a timekeeper at each lane presses a button as the swimmer touches, and the timer ranks the lanes in the order the presses arrive.3 The MC8 gives each lane’s button its own wire back to the timer, so every lane lands on a separate timing channel.14 The start signal takes channel 0 and lanes 1–8 take channels 1–8; in the Timy’s TrackTimer program, lane, channel and display-board address carry the same number.54

ALGE’s catalogues pair the cable with a different start device in each edition. The 2013 system uses an STB1 startbeep and a Timy2 PXE. The 2017 one uses a Timy3 WP with an SPP start speaker and a start push button wired to the timer. The 2026 one uses a Timy3 WP and a BANG2 speaker, with the starter’s 023-10 button plugged into the BANG2 rather than into the MC8.361 In ALGE’s radio alternative, WTN-PB wireless buttons take the place of the cable.1

Design and construction

The 2026 catalogue photographs the MC8-S2 as four small grey junction boxes joined in a chain of grey cable. Each box has two red and two black banana sockets, enough for the buttons of two neighbouring lanes, and cable glands where the cable enters and leaves.1 ALGE’s product page and its US distributor both describe the layout as one connection point between each pair of lanes.24 The catalogue adds that the cabling is assembled to suit the pool, and that the photographed set is the eight-lane form.1

ALGE’s drawings do not all show the same layout. The 2013 and 2017 catalogue drawings put a separate box at every lane, eight in all. The 2023 TrackTimer guide and the 2026 catalogue show four boxes, one per lane pair.3651 The sources do not say whether this marks a hardware change or only a redrawn diagram.

Connection to the timer

The long lead from the junction boxes ends in a 25-pin D-sub plug, with a second short lead ending in a pair of banana plugs; ALGE’s product page calls the D-sub an RS-232 plug.12 The Timy2 and Timy3 have one 25-pin socket, which ALGE calls the multiport. Its pins carry all nine timing channels, together with the RS-232 and RS-485 interfaces, display-board data, a horn output and power.78 The channels are normally open contact inputs, with a maximum loop resistance of 2000 Ω each.8 What the short banana lead connects to is not stated.

The nine channels differ in resolution. Both the Timy2 and Timy3 general manuals give channels 0–5 a precision of 1/10,000 s and channels 6–8 a precision of 1/100 s, so lanes 6–8 are timed to the hundredth.78 The TrackTimer guide’s channel list instead gives channel 5 as 1/100 s as well, which would include lane 5.5

The TrackTimer guide also says that lane timing needs either an ALGE MC9 multichannel unit or a TIDO docking station besides the Timy. ALGE’s 2017 catalogue describes both as boxes that bring the nine channels out to banana sockets.56 The wired drawing in the same guide shows the MC8 running straight to the Timy3 with neither unit, and the 2026 catalogue’s cable system lists no MC9 either.51

Versions and naming

This section lists the names under which the cable has appeared.

NameWhereTimerDrawn boxes
MC8-SWIM2013 catalogue text and drawingTimy2 PXE8, one per lane
MC8-SWIM / MC8-S2017 catalogue (text / drawing)Timy3 WP8, one per lane
MC8-STrackTimer guide, version E23-11-02Timy3 WP4, one per lane pair
MC8-S22026 catalogue, product pageTimy3 W or WP4, one per lane pair

The 2017 catalogue’s text and drawing disagree on the name on the same page.6 ALGE lists the MC8-S2 among its adapters as a “Semiautomatic Adapter” for use with the Timy3 W or WP.2 Whether the S2 suffix marks a revised design is not stated.

Specifications

Lanes8, one push button and one timing channel each
Lane connectionRed and black banana sockets, one connection point per two lanes (MC8-S2)
Timer connection25-pin D-sub plug, plus a short lead with two banana plugs
TimersTimy2 PXE (2013); Timy3 W or WP (2017 onward)
Weight3,594 g (MC8-S2)
LengthNot stated

Part numbers and accessories

This section lists the cable and the parts ALGE names with it.

PartDescription
MC8-S2Current eight-lane cable2
MC8-SWIMName in the 2013 and 2017 catalogues36
023-02Finish push button, one per lane1
023-10Start push button, plugged into the BANG21
MC2-STwo-lane training adapter, listed with the MC8-S22

See also

References

Footnotes

  1. ALGE-Timing, Aquatic Sports (catalogue, June 2026), p. 3. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12

  2. ALGE-Timing, MC8-S2 Semiautomatic Adapter (product page). ↩ ↩2 ↩3 ↩4 ↩5 ↩6

  3. ALGE-Timing, The Specialist for Swimming (catalogue V1.113, 2013), p. 3. ↩ ↩2 ↩3 ↩4 ↩5

  4. ALGE-Swim USA, Systems and Modules (US distributor). ↩ ↩2 ↩3

  5. ALGE-Timing, Timy TrackTimer (version E23-11-02), sections 2, 3.1, 6.1 and 7.1.3. ↩ ↩2 ↩3 ↩4 ↩5

  6. ALGE-Timing, General catalogue (2017), pp. 30 (MC9, TIDO) and 92 (semi-automatic system). ↩ ↩2 ↩3 ↩4 ↩5

  7. ALGE-Timing, Timy2 General (version E130522), 5.1 and 11.1. ↩ ↩2

  8. ALGE-Timing, Timy3 General (version E25-03-10), 11 and 11.1. ↩ ↩2 ↩3

Last updated November 11, 2026.