ALGE TM-SWIM
From Libre Aquatics Wiki, the free aquatics reference
The TM-SWIM is the swim timing console made by ALGE-Timing of Lustenau, Austria, which sells it under the name TimeManager.12 The unit collects lane impulses over two RS485 buses, holds the race data itself, generates the start tone, and connects by USB to a PC running SwimTime. ALGE lists it for its 8-lane and 10-lane swimming systems and gives it a capacity of 16 lanes at each end of the pool.34
Role in the timing system¶
This section covers the TM-SWIM’s place in an ALGE system. ALGE sells two tiers of competition timing. Its semi-automatic packages run from a Timy3 with push buttons, and its fully automatic system runs from the TM-SWIM with touchpads.54
Timing functions execute inside the TM-SWIM and are saved there, and SwimTime displays the race and controls the unit. ALGE’s 2013 catalogue says the computer can drop out once a competition has been set up, and the 2026 catalogue says operation continues through a power cut.64 The catalogues give the internal battery about four hours, running without the mains or a computer.64
Each lane has a SWT3 terminal at each timed end of the pool, and each terminal offers five channels: one touchpad, three push buttons and one relay take-off sensor or instrumented starting block.2 The console counts the terminals on each bus when it switches on and numbers them from the settings in SwimTime, so the terminals themselves carry no lane number.4
The manual shows two reference layouts. One is a single-sided eight-lane pool with a numeric board. The other is a double-sided ten-lane pool with a video screen, OPTIc3 video backup and a separate scoreboard PC. In both, the timing PC and the meet-management PC are different machines joined by a network switch.2
History and predecessors¶
The start of TM-SWIM production is not documented, but ALGE’s website was offering the console by December 2007. That page explains that ALGE gave up the SWC for the new console chiefly to have USB built in.7 A catalogue file of September 2013 presents the unit with the earlier SWT2 terminal, SU2 start unit and P5 printer. It says the TM-SWIM was the first timing device for swimming with a USB interface, a claim made by ALGE alone.6 The firmware change log begins with version 14.21 of February 2014, and the SwimTime log begins in February 2013 with a change of version numbering, so both have earlier history that is not published.89 Splash Software added an ALGE SwimTime interface to its meet manager in April 2010.10
ALGE’s earlier swimming products are known only in part. A 1997 guide describes a Timer S4 with an S4-SWIM lane box that had eight outlets, fed by a separate 5-core cable to a finish adapter for each pair of lanes, with a Start Acoustic SA1 driving up to four horns.11 Hy-Tek Meet Manager and Splash also list an ALGE SWIM 2000.1213 The current firmware page warns that the TM-SWIM firmware must not be loaded onto “the old SWC”, and it calls the TM-SWIM the “new TimeManager”.1 ALGE’s 2002 SWIM 2000 brochure shows the SWC as that system’s controller, gathering impulses from lane terminals on start-side and turn-side bus lines.14 No source found states that the SWIM 2000 replaced the S4.
The accessories have changed around the console. The 2013 SWT2, SU2 and P5 have become the SWT3, SU3 and P6-8, and ALGE warns against mixing the SWT3 with older terminals on one system.1564 Firmware 24.C1 of December 2024 added support for extended terminal hardware that reports a touchpad becoming low-resistance, and SwimTime 2.5.2.1 of February 2025 added a touchpad failure pre-warning for the SWT-DP.89
Design and hardware¶
The console is a portable unit of 260 × 220 × 140 mm and 3.6 kg with a built-in audio amplifier, a 12 V rechargeable battery, and a 10 MHz temperature-compensated crystal oscillator.12 It is supplied with a case, a USB cable, a mains cable and a flash drive holding the software.1 ALGE advises recharging the battery every three months when the system is out of use.2
The front panel has three operating controls. Speech opens the lane speakers for announcements, Line Test starts a line test, and Start fires an internal start impulse. Regulators set the microphone, headset, audio input and overall volume. Three lamps report an error, external supply, and device supply; the error lamp is a general alarm, and the PC gives the specific fault.2
ALGE gives the oscillator a calibration of ±0.1 ppm at 25 °C, a drift of ±2.5 ppm from −25 to 50 °C, and ageing of ±1 ppm a year. The manual converts ±0.1 ppm to ±0.001 s an hour and the 2026 catalogue converts it to 0.00036 s an hour; the second figure is the one the arithmetic gives.24
Connectivity¶
This section lists the console’s connections. Cables are numbered at both ends and the plugs differ by device, a design ALGE says prevents wrong connections.2
Each end of the pool has its own RS485 timing bus. On each bus, cable 200-04 chains the SWT3
terminals together, cable 200-20 or the KT200Z10 reel links the nearest terminal to the console,
and an SWT-END terminator closes the chain.2 See the
ALGE swimming cable sets page for the lane sets.
The start equipment hangs off a separate line. Cable 199-20 or the KT199Z10 reel joins the
console to the SU3 start unit, the FLASH XL
or both, and the SU3 takes all of its power over that cable.216 An
E-START plugs into the SU3.16 The 2013 and 2026 catalogues
list two sockets for this line, and the manual’s double-sided diagram shows a start unit at each
end of the pool.642
Start audio goes to SPA2 and SPP2 lane speakers. An active
SPA2 stands behind each odd lane and drives a passive SPP2 behind the next even lane, and cable
201-07 links the SPA2 units in series from either of the console’s two active-speaker
sockets.2 The console charges the SPA2 batteries while it is on the mains.2
The published port lists do not agree, and no source explains the differences:
| Source | Serial interfaces |
|---|---|
| 2013 catalogue | USB for PC or video; RS232 for display board, printer and video; RS485 for two timing buses and a display board |
| 2024 manual | Four RS232 (PC, display board, printer or results software, video); three RS485 (two timing buses, a display board) |
| 2026 catalogue | USB for PC or video; RS232 for PC or video; two RS232 for the printer; two RS232 for display boards; RS485 for a display board; two timing buses |
The display board port runs at 2400 baud by default and up to 38,400, sends ASCII, and is available on a DIN socket or banana sockets. The video port uses the same format; the manual’s interface list gives its speed as 9600 baud, and its port description and settings screen give 19,200. The manual documents the video data format, covering running time, finish, intermediate, reaction and deleted times by lane. It reserves the PC protocol for internal use, available on special request.2
Software and operation¶
This section summarizes operation from SwimTime. The operator installs SwimTime before first connecting the console, then powers the console and starts the program, which shows the lanes detected. A count that differs from the terminals fitted points to a cabling fault, and the program must be restarted after it is fixed.2 SwimTime version 2.5.4.1 of April 2025 is the current release, for Windows 7 to 11.19
The limit settings hold off false impulses. A block time after the start closes all touchpads, and a second block time closes one pad after each touch. Both default to 10 seconds, and ALGE recommends different values by pool:2
| Pool | Block time after start | Block time after touch |
|---|---|---|
| 25 m, touchpads at one end | 20 s | 20 s |
| 25 m, touchpads at both ends | 8 s | 20 s |
| 50 m, touchpads at one end | 44 s | 40 s |
| 50 m, touchpads at both ends | 20 s | 40 s |
Monitoring settings raise warnings. Lap monitoring compares lap times against a preset 10 seconds, and time-difference monitoring compares touchpad and hand times against a preset 0.30 seconds; both are on by default. An optional setting, off by default, switches to the manual time when it is more than 0.500 seconds away from the pad time.2 SwimTime’s help describes that setting differently; see the SwimTime article. Times are always computed at full precision and truncated to the output precision, which defaults to 1/100 second.2 A Correct Start Time function exists, which the manual says the system does not need but the rules of World Aquatics, then FINA, require.2
The start tone is set in the advanced settings. The manual’s screen shows a default frequency of 1800 Hz, a speaker length of 20 and a headset length of 50. The screen labels those lengths in seconds and the text gives tenths of a second, and neither reading suits a start tone; the start-systems overview compares the settings with field recordings. A simulator mode produces times without hardware and must be switched off for competition.2 The separate SWIM-SIM10 simulates ten lanes on both sides at the hardware level.17
Display settings cover ALGE D-SW boards, by lane or by rank and with reaction and relay times shown or hidden. SwimTime can also drive Omega Calypso boards through a USB-RS485 adapter and Colorado boards through a USB-RS232 adapter, and it feeds D-RTNM matrix boards and network displays.2
The change log records program limits of 400 touches, from October 2016, and 25 km, from May 2022.9 The SwimTime article covers the program itself.
Meet-management software¶
SwimTime exchanges data with meet-management programs by file or over a network share, and ALGE expects timing and meet management to run on different computers.62
Splash Meet Manager and other
LENEX programs use the Splash tab of the network settings. The two
programs pass messages through splash_send.txt and splash_receive.txt in a shared exchange
folder.18 The operator sends the event structure from Splash, times the heat, ends it in
SwimTime, and pulls the results back.19
Hy-Tek Meet Manager uses a separate tab, labelled Hy-Tek
Generic File Sharing, with options for importing the start list and writing results automatically
and a choice of two exchange formats.2 The label matches the
generic network file sharing interface in
Meet Manager, whose documented option names the ALGE Timy rather than the TM-SWIM. SwimTime reads
Hy-Tek’s generic.sch schedule and, since April 2025, .rec record files.9
Other network settings cover IDCam video backup and the D-RTNM boards.2 Since 2018 SwimTime has synchronized IDCam units and OPTIc3 cameras.9
Specifications¶
This table gives the console’s published figures. Where documents differ, each is shown.
| Specification | Value |
|---|---|
| Measuring range | 23 h 59 min 59.9999 s |
| Resolution | 1, 0.1, 0.01, 0.001 or 0.0001 s, selectable |
| Time reference | 10 MHz TCXO |
| Accuracy | ±0.1 ppm at 25 °C; ±2.5 ppm from −25 to 50 °C; ±1 ppm a year ageing |
| Lanes | Up to 16 per side (catalogues); manual’s video format numbers lanes 00–12 |
| Channels per terminal | Five: touchpad, three push buttons, relay sensor or block |
| Temperature range | −25 to 50 °C |
| Mains supply | 100–240 V, 50/60 Hz (manual, catalogues); 90–240 V AC (product page) |
| DC supply | 12–18 V, optional |
| Internal battery | 12 V, two 6 V gel cells; about 4 h |
| Power consumption | 60 W maximum |
| PC connection | USB type B |
| Dimensions | 260 × 220 × 140 mm |
| Weight | 3.6 kg |
| Firmware | TMS 25.71 (July 2025) |
| Conformity | CE declaration dated 30 November 2017; ALGE claims World Aquatics, LEN, NCAA, AAU and SSCH compliance |
Sources: manual, 2026 catalogue and product page.241
Part numbers and accessories¶
This section lists the items ALGE names for the system. The product page lists the console with a case, cable and flash drive; lane equipment is ordered separately.13
| Item | Part number | Article |
|---|---|---|
| Lane terminal | SWT3, with SWT-END terminator | SWT3 swim terminal |
| Lane cable sets | SWCBL8S, SWCBL10S, SWCBL10T; SWSPA8, SWSPA10 | Cable sets |
| Touchpads | TP2400C, TP1890C, TP2300C | TP touchpads |
| Touchpad trolley | CADDY X | CADDY X |
| Push button | 023-02 | 023-02 push button |
| Start unit | SU3 | SU3 |
| Electronic start | E-START | E-START |
| Start microphone | SM8 | SM8 |
| Start flash | FLASH XL | FLASH XL |
| Lane speakers | SPA2, SPP2 | SPA2 and SPP2 |
| Headset | HS4-1 | HS4 headsets |
| Starting platforms | SO5, SO4 | SO5, SO4 |
| Relay take-off sensor | SWR7, SWR7M | SWR7 |
| Backstroke start aid | BSA | BSA |
| Protocol printer | P6-8 | P6-8 |
| Simulator | SWIM-SIM10 | SWIM-SIM10 |
| Transport box | TN-SWIM | TN-SWIM |
| Numeric display boards | D-SW family | D-SW display boards |
In North America ALGE equipment is sold by ALGE-Swim USA and by Nevco.520
See also¶
- SwimTime: the PC software that operates the console
- Timer S4, SWIM 2000 and SWC: earlier ALGE swim timers
- Timy: the ALGE timer used for semi-automatic systems
- Quantum Aquatics and Gen7 Serial Timer: other current consoles with lane bus wiring
- Timers: the timing-console overview
- ALGE-Timing: the manufacturer
- Equipment: the equipment reference
References¶
Footnotes¶
-
ALGE-Timing, TM-SWIM TimeManager (product page, as of November 2026). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7
-
ALGE-Timing, Swimming Timing System Manual (Version E24-08-29). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25
-
ALGE-Timing, Swimming (systems and components, as of November 2026). ↩ ↩2
-
ALGE-Timing, Aquatic Sports (catalogue, June 2026). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9
-
ALGE-Timing, The Specialist for Swimming (catalogue V1.113, 2013). ↩ ↩2 ↩3 ↩4 ↩5 ↩6
-
ALGE-Timing, TimeManager TM-SWIM (archived December 2007). ↩
-
Splash Software, Release notes (build 7735; archived June 2010). ↩
-
ALGE, Swimming System, Timer S4 installation guide (Version E-97-03-24, 1997). ↩
-
Hy-Tek, ALGE SWIM 2000 (Meet Manager guide). ↩
-
Splash Software, Meet Manager 11: How to Start (GeoLogix AG, May 2010). ↩
-
ALGE, SWIM2000 (brochure, 2002; Split Second Timing copy). ↩
-
ALGE-Timing, SU3 Start Unit; Start Unit SU3 manual (Version E-23-11-02). ↩ ↩2
-
ALGE-Timing, Splash Meet Manager quick start manual (June 2025). ↩
Last updated November 4, 2026.