Colorado Time Systems Gen7 wired judging
From Libre Aquatics Wiki, the free aquatics reference
Colorado Time Systems (CTS) Gen7 wired judging is a cabled system for collecting diving and
artistic swimming judges’ scores. It has three parts: a JT-01 terminal for each judge,
CB-01 breakout boxes, and an IH-01 interface hub. The hub connects by USB to a computer
running Gen7 Diving or Gen7 Artistic Swimming.1
CTS released the system in May 2016. It says it built the system because World Aquatics (then
FINA) and USA Diving had asked for wired terminals at national and international
events.23 It is sold in packages of 3 to 15 judges, part numbers JSYS-3 to
JSYS-15.4
Role in the scoring system¶
This section places the system among CTS’s judging products; how a diving panel is scored in general is covered in the diving equipment overview.
Earlier CTS judging terminals reported to a timing console. The wired judging terminals of the System 5 and System 6 were cabled to an interface box at the console, and the later wireless judging terminals reached it by radio.56 Gen7 wired judging leaves the timing console out. A laptop or tablet runs the scoring software, and the interface hub links that computer to the judges.1 CTS’s architectural guidelines describe it as self-contained, with no Gen7 Legacy timer required.7 The same computer sends results to the scoreboard and to a meet-management program.1
History¶
This section covers the system’s release and its use at championships.
In June 2015 CTS said that World Aquatics and USA Diving now wanted wired judging terminals at national and international events, where wireless terminals had been the norm. It showed prototype wired terminals at the USA Diving synchronized national championships and at a FINA Grand Prix in Puerto Rico, and said it planned to release them later that year.2 The release came in May 2016. CTS said by then the equipment had been used at the USA Diving winter and synchronized nationals, the UANA Puerto Rico Grand Prix and the Big Ten and NCAA championships, and that it would be used at the 2016 US Olympic diving trials in Indianapolis.3 The governing bodies’ request is documented in CTS’s releases rather than in a published World Aquatics or USA Diving rule.
USA Diving used the system at its 2022 Winter National Championships at the Mylan Park Aquatic Center in Morgantown, West Virginia. The 2023 National Championships were scheduled at the same pool with the same equipment, according to CTS.8 As of 2026, CTS lists the system as a current product. The software release notes on its product page run to version 1.5.9 of April 2026.9
Design and construction¶
This section describes the three hardware parts.
The JT-01 judges’ terminal is a tabletop unit with a backlit LCD above a sealed keypad. CTS
says the screen can be read in sunlight outdoors as well as indoors.47 The manual’s
drawing shows score keys for 0, .5 and 1 to 10, so marks can be entered in half points. Two
larger keys sit beside the screen: REQUEST CHANGE/CLEAR on the left and SEND/ENTER on the
right.1 The request-change key alerts the operator when a judge needs to correct a mark
already sent.4 The terminal shows the diver’s name and team or country, the dive and its
degree of difficulty, and its own terminal number. Once a dive’s scoring is final it can also
show the other judges’ marks.47 Each terminal has a single 4-pin connector and
locking cable.14
The CB-01 cable breakout box joins the terminals to the bus. Each box has an
Input/Output port at each side for the link to the hub or to the next box. The rest of its
ports are for judges.1 The manual’s drawing shows four judges’ ports beside one I/O port
on one face. All the ports are wired alike, but CTS advises keeping box-to-box and hub links on
the I/O ports. A spare I/O port on the last box in a chain can take one more terminal.1
The IH-01 interface hub converts between the computer’s USB and the RS-485 bus. One end
carries an RS-485 port, a USB socket and a 12 V DC jack with a status LED. The other end has a
second RS-485 port and a quarter-inch phono socket labelled CTS-232, with its own LED.1
The two RS-485 ports are interchangeable. Either one supplies power and data to the terminals
and data to a scoreboard.1
Operation¶
This section covers how the terminals are set up and run from the software.
A terminal switches on when it is cabled to a powered hub and asks for a judge number. That number then appears in the software, where a name can be attached to it. After that the terminal waits for the software.1 To change the number, the terminal must be reset, by unplugging it, or through a reset command that the software sends to every terminal. Duplicate judge numbers stop terminals from sending marks.1
The software sets the terminal mode. Judges Call shows each judge’s number, name and panel letter so judges can find their seats. Judging mode opens the terminals for marks. A waiting mode tells the panel to stand by while the operator deals with a problem.1 Where one judge must give several marks, the software prompts for each in turn.1 The operator can also move entry from the terminals to the computer and type marks in, and CTS says Gen7 Diving works with flash cards keyed in by hand.14 A Judges Hardware setting chooses whether each terminal shows the full panel’s marks once they are in. CTS suggests this for pools where the scoreboard is out of the judges’ view.1
Split panels and simultaneous events¶
The panel layout is set in software rather than by recabling.1 With one breakout box on each side of the pool, a panel can be split across the pool. CTS’s examples are a seven-judge diving panel seated four and three, and halving an artistic swimming panel between the two sides as another.1
Several events can share one bus. Each event has its own computer and hub. One computer sets a system count, the terminals are reset, and each then asks for a system or event ID before its judge number.1 Exactly one computer must be event ID 1, which coordinates the bus. If none is, communication stops and the terminals stay on their waiting screen.1 The manual’s worked example is a 1-metre and a 3-metre event of seven judges each. Each panel puts three judges on the side nearer its board and four on the far side.1 The same cabling, reset to a single system, takes an 11-judge synchronized diving panel.1 That drawing is titled as a 14-judge synchronized diving system, which matches neither layout described in the text beside it.1
Sources differ on how many events can run at once. The manual allows up to four. The datasheet
and product page list simultaneous events only for the JSYS-15 package, without a
number.149
Gen7 Diving software¶
Gen7 Diving organises a competition as meets, events and divers. Each event takes its degrees of difficulty either from the NFHS table or from the World Aquatics formula. CTS lists NCAA, USA Diving, World Aquatics and high school rule sets.14 Per event the operator sets the dive count, the panel size and the number of cast-out marks. A combined event runs several event types, such as girls and boys, at the same time.1 The dive order can follow entry order or meet-management order, be random, or follow the previous round’s finish, forward or reversed.1 The running screen shows the points each diver needs to overtake the top three places. It also gives an average time per dive over the last ten dives and an estimated finishing time.1
Gen7 Diving exchanges data with a meet-management computer over a serial link. CTS names DiveMeets, ieDive and OmadaTrak as compatible programs.41 Entries are imported before an event. Each dive’s marks go back once every judge has scored or, in Hold mode, once the operator sends them.1 Names can be exported as an XML file for DisplayLink Plus or as CSV, with a variant for the Indiana high school association’s reporting system.1 The manual’s troubleshooting table notes that the software refuses events of more than eight divers when no hub is connected.1
Connections¶
This section covers cabling, power and scoreboard output.
The basic chain runs from the computer to the hub by USB. A cable then runs from a hub RS-485
port to a breakout box, and from the box to each terminal.1 The manual’s diagrams label
these runs R-015-569 for the USB cable, R-015-674-30 from hub to box, R-015-674-05 from
box to terminal and R-015-674-75 between boxes across the pool.1 CTS offers cables up to
246 ft (75 m) long.7
The bus can run on USB power alone, which suits a small system without a scoreboard. In that case the terminal backlights cannot be used.1 The external supply that ships with each hub is needed for backlights, for scoreboard data, and for long cable runs. The manual sets the threshold at 100 ft (30 m) in one passage and at 75 m in another.1 On large systems CTS advises powering every hub and, where possible, placing a hub on each side of the pool, because underpowered terminals reset at random.1
Scoreboard data shares the judges’ bus. A scoreboard cable can be taken from any free RS-485 port on a hub or a breakout box, once the hub has external power.1
- An
R-015-674-xxcable goes directly to a numeric board such as a CTS Otter diving scoreboard.1 - An
R-015-707-xcable feeds the scoreboard node of a Gen7 wall plate or deck plate. The plate’s LED for that node turns red if power is too low for scoreboard data.1 - Older RS-232 scoreboards are driven from the CTS-232 port through an
R-xxxDCcable. The hub then acts as a legacy scoreboard converter, a function that is off by default and needs a licence. In this role the data source can be a Gen7 timer as well as the diving laptop.1
DisplayLink Plus reads the same bus. In its templates a Gen7 Diving event ID appears as the pool number, and the timer number names the computer port the diving data arrives on.1 From Gen7 Diving version 1.2.0 the scoreboard feed also carries leaderboard data, so a standings board needs no second connection.10 Version 1.5.8 added an Omega UNT4 output for Daktronics numeric scoreboards.9
Specifications¶
| Manufacturer | Colorado Time Systems, Loveland, Colorado1 |
| Components | JT-01 judges’ terminal, CB-01 cable breakout box, IH-01 interface hub1 |
| Bus | 4-pin RS-485, power and data1 |
| Computer link | USB from IH-011 |
| Legacy scoreboard output | RS-232 on quarter-inch phono socket, licensed feature1 |
| System power | 12 V DC, 1 A maximum1 |
| Power on USB alone | 0.5 A maximum; no terminal backlight1 |
JT-01 current | 25 mA with backlight; 10 mA on USB power1 |
IH-01 current | 75 mA; 50 mA on USB power1 |
| External supply | Listed ITE supply to UL 62368-1 and CSA C22.2 No. 62368-1, LPS, Class 2, 12 V DC 1 A; one ships with each hub1 |
| Maximum cable run | 246 ft (75 m)7 |
| Altitude | Below 2000 m (6500 ft)1 |
| Judges per package | 3, 5, 7, 11 or 154 |
| Software | Gen7 Diving; Gen7 Artistic Swimming1 |
CTS publishes no dimensions or weights for the terminal, breakout box or hub.
Part numbers and accessories¶
This section lists the packages and parts CTS names.
| Package | Judges | Synchronized diving | Simultaneous events |
|---|---|---|---|
JSYS-3 | 3 | No | No |
JSYS-5 | 5 | No | No |
JSYS-7 | 7 | No | No |
JSYS-11 | 11 | Yes | No |
JSYS-15 | 15 | Yes | Yes |
Each package includes its terminals, one or more breakout boxes, an interface hub, the Gen7 Diving software and the cables.4 The datasheet’s third page carries the revision mark “REV: 04/41”, evidently a misprint, where its other pages read 08/23.4
JT-01, judges’ terminal.1CB-01, cable breakout box.1IH-01, interface hub, supplied with its power supply.1R-015-674-05,R-015-674-30,R-015-674-75, RS-485 bus cables as labelled in the manual’s diagrams;R-015-674-xxalso connects a numeric scoreboard.1R-015-569, USB cable from computer to hub.1R-015-707-x, scoreboard cable to a Gen7 wall plate or deck plate.1R-xxxDC, cable from the CTS-232 port to a legacy scoreboard.1- USB Connect (
USB2USB), coupler for the meet-management link. The alternative is two USB-to-serial adapters, linked through a gender changer and a null modem.111
See also¶
- Colorado Time Systems judging terminals: the wired terminals for the System 5 and System 6
- Colorado Time Systems wireless judging: the radio terminals used before it at elite events
- Daktronics JC-100: a competing wired judge console
- Diving equipment: the diving equipment overview
- Colorado Time Systems: the manufacturer
- Equipment: the equipment reference
References¶
Footnotes¶
-
Colorado Time Systems, Diving Installation and User Guide (F1022 Rev 202510). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34 ↩35 ↩36 ↩37 ↩38 ↩39 ↩40 ↩41 ↩42 ↩43 ↩44 ↩45 ↩46 ↩47 ↩48 ↩49 ↩50 ↩51 ↩52 ↩53 ↩54 ↩55 ↩56 ↩57 ↩58 ↩59 ↩60 ↩61
-
SwimSwam, USA Diving Reacts to Sneak Peek of Colorado Time Systems’ Next Generation Diving Equipment (CTS release, June 2015). ↩ ↩2
-
SwimSwam, Colorado Time Systems Releases Next Generation Diving Equipment (CTS release, May 2016). ↩ ↩2
-
Colorado Time Systems, Gen7 Diving datasheet (Rev 08/23). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12
-
Colorado Time Systems, System 5 Judging Terminals datasheet (Revised 06/04). ↩
-
Colorado Time Systems, Wireless Judging 900 MHz Frequency User Guide (F941 Rev. 20110720). ↩
-
Colorado Time Systems, Gen7 Legacy Architectural Guidelines, Gen7 Diving. ↩ ↩2 ↩3 ↩4 ↩5
-
Colorado Time Systems, The 2023 USA Diving National Championships to Use Gen7 Diving at the Mylan Park Aquatic Center. ↩
-
Colorado Time Systems, Gen7 Diving Equipment (product page and release notes, October 2026). ↩ ↩2 ↩3
-
Colorado Time Systems, DisplayLink Plus help, How to Set up a Diving Leader Board. ↩
-
Colorado Time Systems, New Product Spotlight: USB2USB Device. ↩
Last updated October 7, 2026.