Libre Aquatics Wiki

Omega OSM6

From Libre Aquatics Wiki, the free aquatics reference

The OSM 6 is a portable swim timing console made by Omega Electronics, the Swiss sports-timing company whose work is now carried on by Swiss Timing.12 It is housed in a black briefcase with a keyboard, a liquid crystal display and a built-in printer, and times individual and relay races in pools of up to ten lanes from touchpads, pushbuttons and starting blocks.1 Omega supplied it as part of its swimming timing for the 1984 Olympic Games.3 Swiss Timing’s later systems still offer an output in its serial results format, called OSM6 mode.45

Models and naming

This section covers the name and the variants found in the sources.

Omega’s documents write the name as OSM 6 or OSM6, and its American distributors’ advertising as OSM-6.16 The console prints “Omega Swim-O-Matic OSM 6” at the head of every results strip. Swim-O-Matic is the name Omega had used for its swim timing systems since the 1960s, but no source says outright that OSM stands for it.167 The model followed the OSM-5 of 1975.

Two variants appear in software documentation. Hy-Tek’s guide for its Meet Manager interface asks for an “OSM 6 Marc II” fitted with a DH-1 data handling module.8 Splash Meet Manager lists the OSM 6 twice, once as standard and once with no module, both as one-way serial connections.9 Neither source says what else separates the Marc II from earlier units.

Role in the timing system

This section places the OSM 6 in an Omega installation; the general background on timing consoles is on the timers overview.

The console is the centre of an installation that also needs a watertight lane harness, a start system and a means of detecting arrivals.12 Omega’s 1984 Games equipment paired it with OCP5 touchpads, ORA2 start systems, OSB6 starting blocks for relay take-off detection and UNT4 scoreboards.3 An installation can add a one-line or multi-line scoreboard, an audible start signal, a feed for television, and a data handling computer.12

History

This section traces the console from its first appearances to its later use.

The manual’s worked examples carry dates from February 1983 to April 1984, so the console was in use by early 1983.1 Omega’s United States agent at the time, Sportyme of Hatboro, Pennsylvania, advertised it in 1985 alongside CSL swimming software, probably Hy-Tek’s Computerized Swim League.10 In the same year Sportyme cut its prices and offered complete Omega systems of the type used at the Olympics from $4,995.11 It also announced that FINA had given Omega permission to describe its 1984 Games swimming equipment, the OSM 6 included, as “FINA Approved”.3

Omega introduced automatic relay take-off detection at the Los Angeles Games in 1984, after tests by Omega Electronics in 1982, 1983 and 1984. Swiss Timing later explained that the OSM 6 prints the net take-over time between the touchpad and the starting block, without adjusting it.12

By May 1988 Kiefer Sports Timing Systems, of Northfield, Illinois, had become Omega’s exclusive agent in the United States. Kiefer advertised the console in Swimming World in most months until 1990, presenting the briefcase unit as suited to every level of competition, from club meets to the Olympics.613 A 1988 advertisement shows a sample results strip and a FINA Approved mark.6 In 1989 Kiefer and Omega held their first seminar for Omega’s American sales agents and promised lower prices and trade-in offers.14

Canadian pools advertised OSM-6 timing for their meets, the new Pickering pool in Ontario for the 1985 provincial masters championships, and pools in Saint John and Regina for championships in 1991.1516 In 2003 used OSM 6 systems were still offered for sale in Swimming World, with touchpads, scoreboards, speakers and backup buttons, for $4,500 and $5,000.1718 As of 2026 an Austrian event-services company still lists OSM-6 timing among the systems it can supply.19

Design and hardware

This section describes the console’s physical construction.

Everything is built into one black portable case: a control panel with the connection sockets, a keyboard, a display, a printer and a circuit board with two microprocessors.1 The case measures 480 × 380 × 150 mm and weighs 5.8 kg.2 The lid props open on supports, and Omega advises setting the console within sight of the finish, shaded from sun and kept clear of spray from the starting blocks.1

The keyboard has 39 water-protected keys: ten digits and 29 function keys. The function keys are grouped into lane control, race parameters, corrections and printing.12 The display is a 16-character, seven-segment reflective liquid crystal display with 12.7 mm characters. It shows the state of every lane (unused, armed, unarmed, touched or finished), the current lap and the leading lane, along with power and low-battery indicators.12

The printer is electrosensitive. It prints 5 × 7 dot characters, 21 to a line, at about two lines a second, on a metallized paper roll 60 mm wide and 30 m long, enough for about 6,000 lines.12 A plug-in module with 8 KB of memory fits under the printer cover and can be changed without tools. The three swimming programs are built in, so the module is needed only for extra functions or for other sports.1

Timing comes from a 6.144 MHz quartz oscillator. Omega gives its accuracy as ±3 × 10⁻⁶ at 20 °C.2 The console runs from an external 12 V nickel-cadmium or lead-acid battery, drawing 0.7 A on average and 1.5 A while printing. A 9.5 Ah battery lasts about twelve hours at 20 °C.2

Connectivity

This section covers the sockets and the deck wiring.

The control panel has six four-pole plastic sockets, each with its own Omega wiring document:2

SocketUse
Battery12 V supply, by a cable with clips
StartStart transducer; a contact opening starts the timing
ArrivalOmega lane harness carrying touchpad, pushbutton and block signals
Start outRepeats the start impulse to an audible start device or backup timer
Display boardASCII on a 20 mA current loop at 9600 baud
Data handlingAs the board output, or as set by the plug-in module

On deck, a numbered connection module sits beside each lane. A 24 m cable runs from the console to the nearest module, short cables link the modules, and an end plug closes the last one.1 Each module has three inputs, used differently by each program (see below).2 The data sheet allows up to 184 m between the console and the first module, and up to 300 m of twisted, shielded cable to a scoreboard.2

The scoreboard and data handling outputs use seven data bits, one parity bit and one stop bit. A 24-character message goes out every tenth of a second, to clear the board, show the running time or post a time.2 At the console the operator chooses a one-line “Best Time” board or a multi-line board of up to ten lines, in place or lane order.1 During a race the board shows the running time and holds each lap time for ten seconds. A one-line board shows the leader at each lap and can cycle through every finisher at four seconds each.1 A separate mode shows the time of day during breaks.1 Multi-line boards show tenths in the running time, except the UNT 4, which shows whole seconds.2

Software and operation

This section covers the three timing programs and the operator’s controls.

The OSM 6 has three resident programs:12

ProgramLane inputsOfficial time
AUTOTouchpad; one backup pushbuttonTouchpad
AUTO FDTouchpad; one backup pushbutton; starting blockTouchpad, with each relay take-off printed against it
MANUALThree pushbuttonsMedian of three; the second of two; the only one of one

Settings made at switch-on cannot be changed without switching the console off. They are the scoreboard type, the number of lanes, the resolution, the date and the time of day.1 The operator then synchronises the clock to the time of day by holding TEST and pressing START.1

Each race is defined by its program, an arming time of 1–99 seconds, a three-digit event number, a two-digit heat number and a lap count of up to 100. The heat number steps up by one at each new start until the event changes.12 A lane is disarmed after each touch and rearms when the arming time has passed. Omega suggests 15 seconds in a 25 m pool and 45 in a 50 m pool. An arming time of zero leaves arming to the operator.1

In 1/1000 s mode the console prints and displays thousandths but sends hundredths to the scoreboard.12 The manual contradicts itself on ties in this mode: one section says swimmers tie when their times match to the hundredth, following FINA, while another section and the data sheet say they tie only when they match to the thousandth.12

In AUTO FD the console prints, for each relay take-off, the block time minus the touchpad time. A negative figure marks an early take-off, and the result is flagged FD when the block time plus 9 ms falls short of the touchpad time.12 Swiss Timing’s 2001 account of the method describes a 0.03 s allowance agreed between Omega and FINA after the 1982–1984 tests. The sources do not explain the difference between the two figures.12

The console stores every contact, including those on unarmed lanes and after a race has finished. These stored times are not printed, but the operator can recall them to correct the record.12 Three correction keys insert a missing time, replace a time with another stored one or a keyed value, and erase a spurious one, such as a touch from a swimmer leaning over the pad.1 A false start can be erased, and a start missed because the console was not ready can be recovered from memory.1 The printout flags anything out of the ordinary: an asterisk marks a keyed-in time, M a start or arrival given from the keyboard, and T a lane where a MANUAL-program pushbutton was missed.12 Results print in finishing order, with or without backup times, for the current race or the one before it.1

Meet-management software

This section covers how results left the console for a computer.

With the optional Data Handling Module, the OSM 6 sent its results to Hy-Tek Meet Manager. The operator could send the race just finished, an earlier race, or individual splits.20 Hy-Tek’s Interface package listed the OSM6 among the consoles it supported in 1991.20 Hy-Tek’s later guide specifies the connection: an OSM 6 Marc II with a DH-1 module, cabled from the data handling socket through a converter from 20 mA to RS-232, at 9600 baud, even parity, seven data bits and one stop bit.8 The link is one way, so Meet Manager cannot test it as it does a two-way console.8

Splash Meet Manager also reads the OSM 6 over a serial port.9

The OSM6 protocol in later equipment

This section covers the console’s output format as other systems adopted it.

Swiss Timing’s later ARES 21 can send results in an OSM6 mode at the same 9600 baud, seven bits and even parity. Hy-Tek supports it under the same entry as the OSM 6.48 Quantum Aquatics keeps a one-way OSM6 data handling output for results systems.5 Daktronics’ SW-2000 scoreboards have an address setting for the OSM6 protocol.21 Swiss Timing’s StartTime II start system can be set to refuse a start until an ARES or OSM6 has been cleared.22

Specifications

This section gives the figures from Omega’s manual and data sheet.

ItemValue
Lanes1–101
Pools25 m, 50 m and others1
ProgramsAUTO, AUTO FD, MANUAL1
Resolution1/1000 or 1/100 s2
Range23 h 59 min 59.999 s2
Time base6.144 MHz quartz; ±3 × 10⁻⁶ at 20 °C, ±10 × 10⁻⁶ typical over 0–50 °C, ±2 × 10⁻⁶ a year ageing2
Keyboard39 keys (29 function, 10 numeric)2
Display16-character seven-segment liquid crystal display, 12.7 mm characters2
PrinterElectrosensitive, 5 × 7 dots, 21 characters a line, about 2 lines a second2
PaperMetallized, 60 mm × 30 m2
OutputsScoreboard and data handling, ASCII 20 mA current loop, 9600 baud2
Plug-in module memory8 KB1
Power12 V NiCd or lead-acid battery, 10.8–14.4 V; 0.7 A average, 1.5 A peak2
Battery lifeAbout 12 h at 20 °C on 9.5 Ah2
Dimensions480 × 380 × 150 mm2
Weight5.8 kg2
Operating temperature0–50 °C2
Storage temperature−40 to +70 °C2

Sportyme’s 1985 advertisement gave a 10-character display and a 36-key keyboard. The manual and data sheet give 16 characters and 39 keys.1012

Part numbers and accessories

This section lists the numbers named in Omega’s documents and the software guides.

ItemNumber
User’s manual3085-5031
Data sheetE 0013-0141 (the manual cites E 0013-0140)12
Wiring documents: battery, harness, start, board output, board cable, start out3085-506, 3085-507, 3085-508, 3085-509, 3085-510, 3085-5112
Printer paperOmega 9051-6002; Bosch RMP 8146-24V; Silverno 890-2B1
Printer fuse1.5 A slow-blow, 5 × 20 mm1
Data handling moduleDH-18

See also

References

Footnotes

  1. Omega Electronics, OSM 6 User’s manual (3085-503; worked examples dated 1983–1984). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34 ↩35 ↩36 ↩37 ↩38 ↩39

  2. Omega Electronics, OSM 6 Data Sheet (E 0013-0141), bound with the user’s manual. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34 ↩35 ↩36 ↩37 ↩38

  3. Swimming World, November 1985, news item on FINA approval of Omega’s 1984 Games equipment. ↩ ↩2 ↩3

  4. Swiss Timing, Concept ARES 21 Swimming User’s Manual (3330.560.02, version 3.30, April 2008). ↩ ↩2

  5. Swiss Timing, Quantum-Swimming User’s Manual (3480.509.02, version 1.4, October 2019), DH_OSM6. ↩ ↩2

  6. Kiefer Sports Timing Systems, “It’s called the OSM-6”, advertisement, Swimming World, May 1988. ↩ ↩2 ↩3 ↩4

  7. Seagull Enterprises, Omega Swim-O-Matic advertisement, Swimming World, May 1973. ↩

  8. Hy-Tek, Meet Manager 8 guide, Omega OSM 6 or ARES 21. ↩ ↩2 ↩3 ↩4 ↩5

  9. Splash Software, Splash Meet Manager 11 FAQ (October 2011). ↩ ↩2

  10. Sportyme, “The Omega OSM 6 goes on-line with CSL swimming software”, Swimming Technique, February–May 1985. ↩ ↩2

  11. Sportyme, Omega timing systems price advertisement, Swimming World, June 1985. ↩

  12. Swiss Timing, Relay break detection in swimming (official communication 307.225, October 2001). ↩ ↩2

  13. Kiefer Sports Timing Systems, “What perfect timing!”, OSM-6 advertisement, Swimming World, April 1989. ↩

  14. Swimming World, June 1989, Swim Biz News, “Kiefer and Omega to attack U.S. market”. ↩

  15. Pickering Blue Dolphins Masters, 1985 Ontario Masters Championships notice, SWIM Canada, January 1985. ↩

  16. Meet notices for Saint John and Regina, Swim Canada, April 1991. ↩

  17. Classified advertisement, Swimming World, March 2003. ↩

  18. Classified advertisement, Swimming World, December 2003. ↩

  19. MSECM Austria, Timing. ↩

  20. Swimming World, August 1991, timing equipment survey, Omega and Hy-Tek entries. ↩ ↩2

  21. Daktronics, SW-2000 Series 10” Numeric Digit Display Manual (ED-12156, Rev 14, May 2015). ↩

  22. Swiss Timing, StartTime II User’s Manual (document 3399.502.02, Version 2.1, July 2007). ↩

Last updated October 7, 2026.