Swiss Timing Calypso WPO console
From Libre Aquatics Wiki, the free aquatics reference
The Calypso WPO console is the keypad controller that Swiss Timing makes for water polo. From the
officials’ table it keeps the score and runs the game clock, the shot clocks, team fouls,
exclusions and timeouts, and sends them to Calypso or
Piccolo scoreboards. It also drives Swiss Timing’s
water polo shot clocks and a horn.1 The
manual’s running header calls it the WPO Saturn Console, and the shot-clock documents call it
the Saturn Waterpolo or WPO Saturn controller.123 A Swiss Timing
representative in Austria lists it as the Omega Calypso Waterpolo controller, article
3403.900.4 The general background on water polo consoles is on the
water polo consoles overview.
Naming and the Saturn family¶
Saturn is Swiss Timing’s line of multisport indoor scoreboards. Its controller has a 240 × 128 pixel LCD and connects to the boards over RS485, and the current Saturn 2 controller comes loaded with rules for basketball, volleyball, handball, hockey and other hall sports.5 Water polo is not among them. The water polo console belongs to the same family. Swiss Timing’s own documents call it a Saturn console, its manual’s version history lists version 2.0 as the “Waterpolo version”, and the manual notes that a Saturn scoreboard can show the console’s clock time.13
The difference is the protocol it speaks. Swiss Timing’s manual for the Calypso alphanumeric line distinguishes the “Saturn Calypso Waterpolo”, which sends the Calypso protocol used by its Quantum and ARES timers, from the plain Saturn console, which sends the Saturn protocol.6 That fits the console’s two names: a Saturn controller, set up to drive Calypso boards for water polo.
Austrian dealer AVK lists the two controllers with the same 285 × 210 × 84 mm case, the same 1.5 kg weight and the same 240 × 128 display, which suggests one hardware platform loaded with different software.478 Swiss Timing does not say so directly. The console’s own manual gives different figures for its case, 90 × 285 × 205 mm and 1.3 kg.1
Role in the scoreboard system¶
In a water polo installation the console is the centre of the officials’ table. A cable from its scoreboard port carries data to the Calypso or Piccolo boards. The shot clocks take their data and power from a separate power and horn unit, which is cabled back to the console. That unit sounds when the possession time runs out.193 Swiss Timing’s Quantum Aquatics and ARES 21 timers can also drive Calypso boards, and the ARES had its own water polo program and could run the same shot clocks.109 The console does the job without a timing system behind it.
Design and controls¶
The console is a desk unit with a monochrome graphic display in the middle of its face. Four function keys sit above the display, four below and several on each side, and each key’s job is shown on the screen next to it. To the right is a numeric keypad that doubles as a phone-style letter pad for names. There are also ESC, Shift, Horn, Enter, CLR and two arrow keys, and a START/STOP toggle switch that runs the game clock.1
The main menu has four entries:1
- Console set: firmware version, external-control settings, scoreboard and Bluetooth options, team and player names, and the firmware upload.
- Time: the clock and calendar. An internal battery keeps the clock running for 30 days with the console switched off, and settings are kept indefinitely.
- Select: the game settings for each sport, saved per sport, with a reset to the factory values for one sport or for all.
- Play: running a match.
Game settings¶
Settings are saved separately for every sport. The water polo defaults are shown below, set against the current World Aquatics rules.111
| Setting | Console range | Default | World Aquatics, 2026 |
|---|---|---|---|
| Periods | 0–9 | 4 | 4 |
| Period length | Minutes and seconds | 8 min | 8 min of actual play |
| Extra periods | Configurable | 2 of 3 min | None; a tie goes to a penalty shootout |
| Breaks | Three preset lengths | 2, 3 and 5 min | 2 min, 5 min at half time, 2 min |
| Clock direction | Up or down | Down | Not specified |
| Possession time | 0–99 s, two values | 25 s and 15 s | 28 s, and 18 s after certain restarts |
| Timeouts | 0–3, per game or per period | 2 per game | 2 per team per match |
| Timeout length | 0–99 s | 60 s | 1 min |
The console’s defaults do not match the current possession rule, and the manual does not agree with itself either. Its headings and version history refer to resetting the shot clock to 30 s and 20 s, while its settings screens and default table show 25 s and 15 s.1 Swiss Timing’s 2015 shot-clock datasheet also describes the clocks as 30/20 s.2 World Aquatics now allows 28 s of possession, and 18 s after a penalty throw, a corner throw and some other restarts.11 An operator has to set both values by hand before a match played under current rules. Likewise, the factory extra periods have no place in a World Aquatics match, which is decided by a shootout when it ends level.11
Other settings cover the scoreboard and the horn:1
- Tenths of a second during the last minute of a period, and during the last 10 s of possession.
- Whether game time stops when the shot clock reaches zero. The shot clock can also be started together with the game time, or blanked when the remaining game time is shorter than a full possession.
- Six programmable exclusion times, a maximum number of personal fouls per player, and whether the console asks for the player’s number with each goal or foul.
- Horn lengths at the close of each period, with one minute to go in the final period, at the close of a break or timeout, and a warning before a timeout ends. An optional one-second horn can sound 30 s before a break ends.
- The scoreboard type: Calypso or Piccolo, horizontal or vertical, and 6, 8 or 10 lines.
Running a match¶
On entering Play the console asks whether to pick up the last game or begin afresh. It will not start while the START/STOP switch is in the START position.1
The screen is split into the game area in the middle and a column for each team. Raising the switch starts the period. The operator adds goals, team fouls, exclusions and timeouts with the function keys beside each team, and takes them back with Shift. If player tracking is enabled, the console asks for a cap number with each goal or foul. It tracks which players are in the pool, and drops a player from the lineup on reaching the foul limit or on being excluded. Exclusions count down on the board, and the operator can correct them or reassign them to another player.1
Game time can be corrected while stopped, down to the tenth of a second, together with the possession time and each team’s exclusion times. When game time is changed, the console offers to shift all the exclusion clocks by the same amount. A countdown of any length can be shown at any stoppage, for example for a warm-up.1
The period does not advance by itself, so that scores can be corrected first. When a period ends the operator moves on and chooses whether to reset team fouls, timeouts, both or neither. A preset break or no break can then be shown before the next period. After the final period the console offers an extra period or ends the game. After GAME OVER the game cannot be restarted.1
External controls¶
The console can share control with switches on the deck. A start/stop box and a reset button plug into two 3-pin sockets on the back.12 The manual shows seven arrangements. At one extreme the console’s own switch runs everything. At the other, one external switch runs the game clock and a second one starts, stops and resets the shot clock. In between, the external box takes over the shot clock only, or the game clock only.1 On the reset button a single press returns the shot clock to the first possession time and a double press to the second.1
A third socket takes a coach’s timeout contact, normally open by default. A coach’s request can start the timeout immediately or wait for the operator to confirm it. At the start of the third period the console asks whether the teams have changed ends, so that the two coaches’ buttons can be swapped. If play resumes before a timeout has run out, setting the switch to START clears it.1 A further 3-pin socket labelled POSSESSION has contacts for the home and visiting teams. The manual gives its pinout but does not describe how it is used.1
Scoreboards and peripherals¶
The console’s examples show water polo layouts on six-line horizontal and ten-line vertical
Calypso boards, and on a Piccolo. Each team’s score, timeouts and up to three exclusion clocks
are shown, plus the period and game time.1 Team names need an optional team-name module,
article 3400.740. The water polo version cannot send player
names.1 A test function sends a test pattern to the boards, though not every board type
supports it.1
With the optional internal Bluetooth module the console can pair with Bluetooth-equipped scoreboards that share its password. It steps through each board it finds and asks whether to link it. The module takes over one of the two transmit pairs on the scoreboard socket, so wired boards must then use the other one.1
Shot clocks are supplied as kits of two or four with a power and horn unit, 30 m and 70 m cable reels and a cable to the console.93 Dealer AVK offers two shot-clock families with the console, the Calypso clocks and the larger Montreal shot clocks, together with the Coyote horn.812
Connections¶
The rear panel carries:1
| Socket | Connector | Use |
|---|---|---|
| SCB | Tuchel 7-pin female | RS422 to the scoreboards: +12 V, two transmit pairs, ground |
| PC | 9-pin Sub-D | RS232, for firmware updates |
| POSSESSION | 3-pin | Home and visitors contacts, common |
| START/STOP + RESET | 3-pin | External start/stop and shot-clock reset |
| START/STOP | 3-pin | Second external start/stop |
| POWER | DIN 4-pin male | 9–18 V DC |
| HORN | Banana terminals | Horn output |
Firmware¶
New firmware is loaded from a PC. The console connects to the PC’s serial port, directly or
through a USB adapter, with a straight 9-pin cable (Swiss Timing 9051.1307).
FlashSimple, a program Swiss Timing provides for download,
writes the file to the console’s Renesas H8S/2134F microcontroller in about four
minutes.1 After an update the manual requires the operator to restore all sports to
their factory settings, which erases any saved settings.1 The firmware shown in the
2026 manual is version 1.63.1
Care and maintenance¶
Swiss Timing asks for the console to be wiped with a soft cloth, slightly damp, or with a little soapy water if it is very dirty, keeping water out of the openings. It is stored clean and dry.1
Specifications¶
| Specification | Value |
|---|---|
| Display | Monochrome graphic LCD, 240 × 128 pixels8 |
| Controls | Function keys, numeric keypad, START/STOP switch |
| Players per team | Up to 16 |
| Scoreboard output | RS422, Tuchel 7-pin; two transmit pairs |
| PC port | RS232, 9-pin Sub-D |
| External inputs | Start/stop, start/stop and reset, possession, coach’s timeout |
| Wireless | Optional internal Bluetooth module |
| Power | 9–18 V DC, DIN 4-pin |
| Clock backup | 30 days on the internal battery |
| Dimensions | 90 × 285 × 205 mm (manual); 285 × 210 × 84 mm (dealer) |
| Weight | 1.3 kg (manual); 1.5 kg (dealer) |
| Operating temperature | 0–45 °C |
| Storage temperature | −10–60 °C |
Part numbers and accessories¶
3403.900: Omega Calypso Waterpolo controller, per AVK.43400.740: team-name module, needed to send team names.19051.1307: RS232 cable for firmware updates.13403.950.CA,3403.951.CA,3403.790: Calypso water polo shot clocks.3133435.904: Montreal shot clocks with game clock.123435.900: Coyote horn.143500.900: Saturn 2 multisport controller, the hall-sports counterpart.7
See also¶
- Calypso and Piccolo: the scoreboards it drives
- Swiss Timing water polo shot clocks: the possession clocks it runs
- Saturn 2: the multisport scoreboard family it belongs to
- WTTC-1 Tabletop Controller: the Colorado Time Systems water polo controller
- Water polo consoles: the water polo consoles overview
- Scoreboard control: the scoreboard control overview
- Water polo equipment: the water polo equipment overview
- Swiss Timing: the manufacturer
- Equipment: the equipment reference
References¶
Footnotes¶
-
Swiss Timing, Calypso WPO Console Instructions for Use (3403.504.02, version 2.7, January 2026). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30
-
Swiss Timing, Calypso LED Shot Clocks datasheet (Calypso_Shot Clocks/10-2015). ↩ ↩2 ↩3
-
Swiss Timing, WPO Shot Clocks User’s Manual (3403.514.02, version 1.1, September 2023). ↩ ↩2 ↩3 ↩4 ↩5
-
AVK Group, Omega Calypso Waterpolo controller (3403.900) (Swiss Timing representative). ↩ ↩2 ↩3
-
Swiss Timing, Saturn 2 Multisport Scoreboard datasheet (2013). ↩
-
Swiss Timing, Calypso Alphanumerical 17-character Line User’s Manual (3403.507, version 1.2, June 2018), 2.3. ↩
-
AVK Group, Omega Multisport controller Saturn 2 (3500.900). ↩ ↩2
-
AVK Group, Water polo scoring and timing system (STWP). ↩ ↩2 ↩3
-
Swiss Timing, Water polo Shot Clocks User’s Manual (3403.511) (March 2014). ↩ ↩2 ↩3
-
Swiss Timing, Calypso 8-digit LED Scoreboard User’s Manual (3403.500, version 2.2, August 2016). ↩
-
World Aquatics, Competition Regulations, Part Six, 4, 5 and 9. ↩ ↩2 ↩3
-
Swiss Timing, Montreal LED Shot Clocks datasheet (2013). ↩ ↩2
Last updated October 7, 2026.