Libre Aquatics Wiki

Swiss Timing Quantum Aquatics

From Libre Aquatics Wiki, the free aquatics reference

Quantum Aquatics is a swim timing console made by Swiss Timing and sold under the Omega name. It is an interface box that time-stamps every contact from the pool and passes the record to a computer, which runs Swiss Timing’s Quantum Swimming software and does all the race processing.12 It comes as a single Primary timer or as a Primary & Secondary pair of complete timers with a data switch between them.13 Its manuals begin in 2012, and it took over from Swiss Timing’s earlier ARES 21 system.145

Role in the timing system

This section places Quantum in an Omega swimming installation; the shared background on timing consoles is on the timers overview.

The console sits between the pool and the computers. Touchpads, starting blocks with relay take-off detection and backup pushbuttons connect lane by lane to a harness, and the harness connects to the console. A StartTime starter supplies the start signal, and serial ports feed scoreboards and a meet-management computer.16 Every contact reaches the console with a code identifying where it came from. The console keeps the time base and buffers the events; result lists, records and scoreboard pages are produced on the PC, so the number of stored races depends on the PC’s disk.1

Swiss Timing’s datasheet presents Quantum as fit for school meets and for Olympic and world championship competition alike.3

History and predecessors

This section traces Quantum from the ARES 21 system it replaced.

Before Quantum, Swiss Timing’s swimming system was ARES 21: an IF-ARES interface box linked by an RS-232 cable to a PC running ARES Swimming, documented in a 2008 manual.5 Quantum keeps the same division of work. Harness modules are mapped to lanes in a pool-configuration screen, the clock is synchronised at the start of a session, and data handling uses the same set of “Lst” text files, which the Quantum manual calls the ARES file type.52

The Quantum Concept manual’s first version is dated 1 May 2012, and the RFID programmer for Quantum’s harness modules dates from January 2012.14 Swiss Timing’s general swimming installation guide added Quantum in July 2013.6

The 2019 software manual covers versions 1.6.6 to 1.6.10.2 In January 2021 Splash Meet Manager added a second Quantum interface that exchanges data over UDP and TCP instead of shared files. By August 2024 Splash’s newest features required Quantum software 6.1.19 or later.7

Design and hardware

This section describes the console’s two versions, inputs and outputs.

The Primary console contains one timing system. Each lane module sends it five contacts: the touchpad, the starting block’s relay break detection and three backup buttons.1 The Primary & Secondary console contains two complete timers in one case, each with its own power input and printer port. A data switch selects which timer’s results go out, and each lane module carries ten contacts, the same five for each system.1 Swiss Timing lists a Primary model with an internal power supply (3480.911.IS) as well as one without (3480.911).3

The console runs from an external 12 V battery or power pack. It has two DC inputs, so one battery can be changed without stopping, even during a race.1 With battery-powered PCs and printer, Swiss Timing says a meet can continue through a complete mains failure.1 The console records time to 23:59:59.99 and resolves 1, 1/10 or 1/100 s from a 1/10,000 s sampling rate.1

Swiss Timing asks for the console to be shaded from the sun, kept away from splashing at the blocks, and cleaned and dried after each competition. It ships with a calibration certificate valid for four years, after which the console goes back to Swiss Timing or a reseller for recalibration.12

Connectivity

This section covers the pool cabling and the console’s data ports.

The pool side connects through one of two cabling schemes:189

SchemeLane connectionLink to the console
MobileA Quantum Mobile Harness module at each lane, chained module to module, up to ten per pool end, with a terminator on the lastOne 25 m cable, extendable to 50 m or more on drums
FixedIn-deck deck plates wired back to an ODB10-SW distribution box in the timing roomUp to 100 m from deck plate to box and 200 m from box to console

Either scheme joins the console at its harness inputs, HA1 for the finish end and HA2 for the other end. Swiss Timing’s cabling diagrams run from one harness on a Primary console to two harnesses on a Primary & Secondary console.16 Each lane module carries its lane number, from 0 to 9. Swiss Timing sets the numbers at the factory, and the Programmer AQ rewrites them on site by RFID when a module is replaced.84 The lane sockets are colour-coded: yellow for the OCP5 touchpad, white for the starting block, red for a pushbutton.8

The start system plugs into the START inputs: START1 at the finish end and START2 at the other end, for a StartTime starter.110 The console sends the starter a ready signal when the race is armed.211

The console’s other ports are:1

  • USB to the PC;
  • RS422 serial ports, two on the Primary and four on the Primary & Secondary, for scoreboards and data handling;
  • a serial printer port per timer;
  • banana inputs and outputs, and on the Primary & Secondary model start-pulse outputs.

Software and operation

This section summarises the Quantum Swimming program that runs the console.

Quantum Swimming is a Windows program installed with Swiss Timing’s support libraries and a USB driver, and licensed by a USB dongle. A race cannot be started without the dongle, but a three-day code can be requested online if it is lost before a meet.2

The console’s clock is synchronised at the start of each session, from the PC’s time, from a typed time, or from a start pulse. The start pulse is the preferred method when two timers must agree, and the starter’s ready lamp relights two seconds later so the operator can check the result.2 Each meet is a folder on the PC. Swiss Timing recommends one meet per session, because the program does not separate the two.2

Before a meet, the operator configures the pool:2

  • the pool length, 25 or 50 m;
  • which side is the finish;
  • which harness is on which input;
  • what equipment each lane has;
  • how harness modules map to lanes, so that, for example, two modules in the centre of a ten-lane pool can be run as lanes 1 and 2.

A pool test counts contacts lane by lane so the setup can be checked from the pool side.2

During a race, the timing window shows each lane’s laps, rank, direction and arming state, and lets the operator add or remove laps, take a backup time, or mark a swimmer as DSQ, DNS or DNF.2 Reaction-time and relay-exchange windows are set per meet, typically 2 s and 1 s.2 If a start is fired while the race is not armed, the program keeps its time, and the operator can attach it to the race afterwards.2 A backup time that differs from the touchpad time by more than 200 ms is flagged.2 When the result is marked official, the program can print it, send it to the scoreboard, export it and update the records table.2

The program drives three kinds of scoreboard output:26

  • Swiss Timing’s alphanumeric protocol, for 12-line, 32-character boards;
  • the ERTD protocol used by other makers’ alphanumeric boards;
  • a numeric output for Swiss Timing’s Calypso boards.

Meet-management software

This section covers the four data-handling links in the program and how other software connects.

LinkHow it works
Lst filesImports the schedule, start lists and records from the ARES-format text files and writes results to another file in the same set2
OSM6Sends results one way over a serial port, for data-handling systems that load their schedules from Lst files2
Hy-TekShared folder: Meet Manager writes the schedule and start lists, Quantum writes a .qaq result file per race212
SplashShared folder with a send file and a receive file213

Hy-Tek Meet Manager lists the console as Omega Quantum-AQ, beside Omega’s older OSM 6, ARES 21 and Power Time.14 Its guide describes the same shared folder, with result files ending in .qaq.12 The two vendors name the start-list files differently. Swiss Timing’s manual expects files called quantum.sch and startlist.slx, while Hy-Tek’s guide writes a start list called quantum.slx and, from Meet Manager 7.0, a records file called quantum.rec.212

Splash Meet Manager reads and writes a shared folder from build 20948, with Quantum set to its Splash protocol.13 In January 2021 Splash added a second interface over UDP and TCP, and later releases fixed compatibility between the two protocol versions.7

Daktronics states that its RTOP relay take-off platforms do not work with a Quantum console.15

Specifications

This section gives Swiss Timing’s figures; the 2015 manual and the 2015 datasheet differ on three of them.

ItemValue
Time capacity23:59:59.99, repeating1
Resolution1, 1/10 or 1/100 s; sampling 1/10,000 s1
Ageing±4 ppm over 10 years1
Stability±0.1 ppm, 0–45 °C1
SupplyExternal battery, 9–18 V DC (manual) or 10–18 V DC (datasheet)13
CurrentPrimary 0.5 A (manual) or 0.55 A (datasheet); Primary & Secondary 1.1 A13
Current with 24 harness modulesPrimary 1.00 A; Primary & Secondary 2.0 A3
Operating temperature0–60 °C1
Humidity20–80 % (manual) or 0–94 % (datasheet), non-condensing13
PC linkUSB1
LanesTen modules per pool end, numbered 0–98
CertificationCE1

Part numbers and accessories

This section lists the part numbers in Swiss Timing’s documents.

PartNumber
Quantum Primary, without internal power supply3480.9113
Quantum Primary, with internal power supply3480.911.IS3
Quantum Primary & Secondary3480.9123
Power supply, Primary & Secondary3480.9323
Mobile harness sets, Primary, 10, 8 or 6 lanes3480.950, 3480.958, 3480.9568
Mobile harness sets, Primary & Secondary, 10, 8 or 6 lanes3480.960, 3480.968, 3480.9668
Harness terminator3480.77018
Harness cable to the console, 25 m1892.02518
Harness extension cables, 50 m and 75 m on drums (the concept manual lists 50 m and 100 m)1892.050, 1892.075, 1892.10081
USB cable9051.13161
Programmer sets3480.921, 3480.9224
Laptop-compatible Quantum3397.9103
Cases3480.925, 3480.9263
Battery online printer; thermal printer3480.920; 3330.6613
Bluetooth RS422 adapter3440.7083
Double-start cable3330.6513

See also

References

Footnotes

  1. Swiss Timing, Quantum Concept Swimming User’s Manual (3480.508.02, v1.4, July 2015). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30

  2. Swiss Timing, Quantum-Swimming User’s Manual (3480.509.02, version 1.4, October 2019). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21

  3. Swiss Timing, Quantum Aquatics datasheet (Quantum AQ/10-2015). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16

  4. Swiss Timing, Programmer AQ User’s Manual (3480.501.02, v1.1, January 2019). ↩ ↩2 ↩3 ↩4

  5. Swiss Timing, Concept ARES 21 Swimming User’s Manual (3330.560.02, version 3.30, April 2008). ↩ ↩2 ↩3

  6. Swiss Timing, Swimming Concept: Quantum / OSB with footrest (0017.509.02, v4.9, January 2017). ↩ ↩2 ↩3 ↩4

  7. Swim Wiki, Meet Manager: Release Notes (January 2021 to August 2024). ↩ ↩2

  8. Swiss Timing, Quantum Mobile Harness User’s Manual (3480.500.02, v1.1, August 2019). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9

  9. Swiss Timing, ODB10-SW User’s Manual (3494.501.02, v1.7, December 2018). ↩

  10. Swiss Timing, StartTime V User’s Manual (3481.560.02). ↩

  11. Swiss Timing, StartTime IV E-Gun User’s Manual (3481.501.02). ↩

  12. Hy-Tek, Meet Manager 7 guide, Omega Quantum-AQ. ↩ ↩2 ↩3

  13. Swim Wiki, Meet Manager: Timing System Omega Quantum Aquatics. ↩ ↩2

  14. Hy-Tek, Timing Console Interface Vendor Contacts. ↩

  15. Daktronics, Which RTOPs, starting blocks, and third-party timing systems are compatible (KB DD2090313). ↩