Libre Aquatics Wiki

ALGE Timer S4

From Libre Aquatics Wiki, the free aquatics reference

The Timer S4 is a battery-powered, multi-sport timer made by ALGE-Timing of Lustenau, Austria, as the successor to its Timer S3.1 It has 18 timing channels and eight built-in programs, one of them for swimming. With that program, an S4-SWIM lane box, FIN1 finish adapters and a Start Acoustic SA1, the S4 formed ALGE’s eight-lane swimming system, which an installation guide dated March 1997 describes.2 The S4 is also homologated by FIS for ski timing and approved by the FEI as a time base for show jumping.34

Role in the timing system

This section describes how the S4 fits into ALGE’s swimming system. The timer sits at the timing desk, where it records and prints the times. Everything on the pool deck reaches it through the S4-SWIM, which plugs into the timer’s 25-pin multi-channel socket.2 The S4-SWIM holds a switch for each lane’s touchpad and the socket for the SA1, and a 5-core cable 078 runs from it to a FIN1 at every second lane. Each FIN1 takes the touchpads and backup handswitches of two lanes.2

The starter works from the SA1. One press of its handswitch starts the S4 and sounds up to four LK1 horns, and a second press within five seconds sends the false-start signal.2 Q34 headsets at the timer and at the SA1 let the starter and the timekeeper talk to each other. Results go to a Printer P4 on the timer, to GAZc display boards, and to a computer over RS232.2

History and predecessors

The S4 manual presents the timer as the successor to the S3 and says the older model had been in use worldwide for more than ten years. The manual tells S3 owners that the S4’s split program will be familiar, and that ALGE sensors and accessories made for earlier timers work with the S4 unchanged.1 The serial output was not carried over: according to a 2007 post on a timing forum, the S3 sent 2400 baud with 7 data bits and 2 stop bits, against 4800 baud with 8 data bits and 1 stop bit on the S4, and the records differ slightly, so software set up for one does not read the other.5

The swimming system’s drawings carry the date 3 November 1994, and the installation guide is version E-97-03-24.2 ALGE’s English S4 manual is dated April 2006, and a German edition of September 2010 still describes the swimming program with the S4-SWIM and the SA1.16 ALGE also sold the S4 as a show-jumping timer, paired in a German brochure with printers and display boards of later generations than the P4 and GAZc.7 No source found gives the S4’s introduction or withdrawal date. FIS listed it in 2010 under homologation number ALG.005.97, valid until 2011, beside the S3 as ALG.004.97.8 FIS later renewed the S4 under ALG.005T.10; as of November 2026 that homologation is guaranteed through the 2028 season, while the S3 is no longer listed.3

The S4 does not appear in ALGE’s 2013 or 2026 swimming catalogues, which show touchpads, terminals and consoles of later generations.910 By January 2002 ALGE was documenting a different swimming system, the SWIM 2000. Its timer is the SWC controller, which collects impulses from lane terminals chained on one bus cable, serves up to 12 lanes and works with timing software on a PC.1112 No ALGE document found says that the SWIM 2000 replaced the S4 system.

Design and hardware

This section covers the timer itself. The S4 is built in an anodized aluminium case with a handle held by knurled screws.1 Its front carries an eight-digit liquid-crystal display, a red start/stop key, a yellow “next” key, a three-position switch that selects clock A, B or C, a second switch for program selection, line test and options, and a meter used to check battery level, photocell alignment and the start line. Pressing both keys together resets the selected clock.1

Timing comes from a temperature-compensated crystal oscillator at 9.216 MHz. Precision can be set to 1/10, 1/100 or 1/1000 s for the display, printer and display board; the computer output always carries thousandths. The memory holds 8,000 times, each with a running ID number, and keeps them when the timer is switched off.1

The S4 runs on six C cells, either alkaline or NiCd. NiCd cells are needed when the P4 printer is fitted, and a coloured mark on the back of the case shows which type the charging circuit is set for. The NLG4 mains set or an external 12 V battery can power the timer, with the internal cells as backup.1 In the swimming system, the 1997 guide gives about four hours of operation for the whole system from the timer’s own cells, and expects the S4 to run normally from a 12 V car battery or the NLG4.2 The manual’s battery figures, for ski-style use with photocells, run from 12 to 112 hours depending on the load and cell type.1

Connectivity

This section covers the S4’s sockets and the swimming layouts that use them. The rear panel has three DIN sockets for course A, B and C sensors, each also able to take the NLG4; a fourth DIN socket for power; sockets for the display board, the P4 printer and an RS232 computer link; a headset socket; a loudspeaker socket for a count-down horn; banana sockets for four of the channels; and the 25-pin socket that carries all 18 channels.1 The display-board socket carries two data channels, and turning the cable 010-10 plug over swaps which one reaches the board.1

The 1997 guide shows three swimming layouts:2

LayoutEquipment
Without false-start systemOne Timer S4 with P4 and NLG4; one S4-SWIM; four cable 078 runs to four FIN1 adapters; one SA1 with four LK1 horns, a handswitch and a Q34 headset; eight GAZc boards on a mains supply
With false-start systemTwo Timer S4s, each with its own P4 and NLG4; one S4-SWIM serving finish adapters at both ends of the pool; two SA1s, one on each side, each with four LK1 horns; a False Start Detector R1 at each lane
Under-deck installationA SWIM-FIX box on a mains supply, cabled to each starting block

The guide does not explain the false-start system or the R1 in its text. For a fixed installation it gives conduit sizes, and it advises that each FIN1 be mounted in a lockable box where ALGE starting blocks are not used.2

Software and operation

This section describes the swimming program and the S4’s other programs. The timer’s eight programs are split or sequential timing, three-course timing, show jumping, an 18-channel timer, parallel slalom, speed measurement, swimming, and an automatic mode for unattended training runs.1 The manual names swimming among the uses of the automatic mode.1

The swimming program, program 6, handles up to eight lanes. Before each heat the operator enters the number of touches each lane must make (1–99), the event and heat numbers, and a finish delay of 10–99 s during which a pad ignores further touches after registering one. The start comes from the SA1. The P4 prints each touch as it arrives. Once every lane has reached its count, the timer prints a ranking of the race times, followed by the handswitch times and the final times listed by lane. The red key closes a heat in which a swimmer does not finish, and a reset advances the heat number by one.1

The GAZc boards can be used in two ways. With one board per lane, a thumb-wheel switch on each board selects the placing it shows, so the stack of eight boards reads as a ranking from first to eighth. With a single board, the board shows the winner’s time first and the operator steps through the other placings with the yellow key; after the last time the printer produces the full result.2

Meet-management software

The S4 sends each time over RS232 as a line of text with a four-digit ID number, a channel or course marker, and the time to the thousandth. A computer can also request the whole memory or a block of it, clear it, and change baud rates and precision by sending one-byte control codes.1 A user report from 2002 describes the effect of a full memory: once 8,000 times are stored, the S4 stops sending times to the computer while the printer carries on, so the memory has to be cleared before an event rather than during it.13

Splash Meet Manager reads the S4 through a one-way serial interface, listed as “ALGE S4” in its May 2010 guide and October 2011 FAQ and as “ALGE S-4” in its 2018 brochure.141516 Splash’s release notes record a correction to the S4 interface in March 2008 and a fix in October 2008 for timing printouts in English.17 Outside swimming, Split Second Sports Timing’s ski software reads the S4 in its 18-channel program at 4800 baud.18

Specifications

Figures are from the S4 manual unless noted.1

SpecificationValue
Measuring range23 h 59 min 59.999 s
Precision1/10, 1/100 or 1/1000 s, selectable; computer output always 1/1000 s
Time reference9.216 MHz TCXO
Accuracy±2.5 ppm from −30 to 75 °C; ±1 ppm a year ageing; adjusted to ±0.1 ppm at 25 °C
Operating temperature−25 to 50 °C
Timing channels18
Memory8,000 times, retained when switched off
Display8-digit LCD, 12.7 mm figures
Swimming lanes8
PowerSix C cells (alkaline or NiCd); NLG4 mains set; external 12 V battery
Current drawAbout 60 mA without external devices
Sensor supply5 V DC, 120 mA maximum
Computer interfaceRS232, 4800 baud default (1200–9600)
Display-board and printer interfaces2400 baud default (to 19200)
Loudspeaker output8 Ω, 24 V peak to peak maximum
Dimensions226 × 162 × 95 mm
Weight2.2 kg with batteries
FIS homologationALG.005.97 (to 2011); ALG.005T.10 (to 2028)83

Installation and safety

This section covers the guide’s advice on the deck equipment. ALGE told pools to keep the touchpads in the water only during competition and to store them on a trolley at other times. The guide names the pad TP24 in its text but TP1 on its drawings, and the S4 manual also uses TP1.21 It gives two sets of dimensions for the pad, 2450 × 945 mm on its first page and 2444 × 910 mm on its touchpad page; ALGE’s 2013 catalogue lists the TP24 at 2444 × 906 × 10 mm.29 See the TP touchpads article for ALGE’s touchpad line.

Part numbers and accessories

This section lists the parts of the S4 swimming system that have articles here.21

ItemPart numberArticle
TimerS4This article
Lane switch boxS4-SWIMS4-SWIM
Finish adapterFIN1FIN1
Lane cable078Cable 078
TouchpadTP24 (TP1 on drawings)TP touchpads
Handswitch023-10023-02 push button
Start unitSA1Start Acoustic SA1
Start speakerLK1LK1
HeadsetQ34Q34 headset
PrinterP4Printer P4
Mains charging setNLG4NLG4
Display boardGAZcGAZc
Display data cable010-10Cable 010-10
False start detectorR1R1
Under-deck junction boxSWIM-FIXSWIM-FIX

See also

References

Footnotes

  1. ALGE-Timing, Timer S4 manual (Version E-06-04-18). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17

  2. ALGE, Swimming System installation guide, Timer S4 (Version E-97-03-24). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13

  3. FIS, Homologated Timing Equipment (database, as of November 2026). ↩ ↩2 ↩3

  4. FEI, Timing devices approved for use at FEI Jumping Events (November 2017). ↩

  5. TimingGuys, ALGE timing software vs S4 (forum thread, March 2007). ↩

  6. ALGE-Timing, Timer S4 Bedienungsanleitung (Version D-10-09-02; in German; ManualsLib copy). ↩

  7. ALGE-Timing, Timer S4: die ideale Zeitmessanlage für Springreiten (brochure; in German). ↩

  8. FIS, Homologated Timing Equipment (list valid as of 22 October 2010). ↩ ↩2

  9. ALGE-Timing, The Specialist for Swimming (catalogue V1.113, 2013). ↩ ↩2

  10. ALGE-Timing, Aquatic Sports (catalogue, June 2026). ↩

  11. ALGE, SWIM2000 (brochure, 2002; Split Second Timing copy). ↩

  12. ALGE, SWIM2000 Architectural Guidelines (Version E-02-01-24). ↩

  13. TimingGuys, Alge S4 stops transmitting times to the PC (forum thread, September 2002). ↩

  14. Splash Software, Meet Manager 11: How to Start (GeoLogix AG, May 2010). ↩

  15. Splash Software, Splash Meet Manager 11 FAQ (October 2011). ↩

  16. Splash Software, Splash Meet Manager (product brochure, April 2018). ↩

  17. Splash Software, Release notes (archived June 2010). ↩

  18. Split Second Sports Timing, ALGE S4 (connecting timers). ↩

Last updated November 8, 2026.