Deck cabling
From Libre Aquatics Wiki, the free aquatics reference
Deck cabling, in swimming timing, is the wiring between the equipment at each lane and the timing console. At each end of a racing pool a lane can have a touchpad, up to three backup pushbuttons, a relay judging platform and a lane speaker, and the console has to receive each lane’s signals separately so that it can tell which lane produced them. Facilities do this in one of two ways. An on-deck harness is laid along the pool edge for a meet and packed away afterwards. An in-deck system runs permanent cable through conduit under the deck to a deck plate set flush beside each starting block, with a wall plate or a distribution box where the console plugs in.123 This page covers both schemes and the parts that join them to the console.
The equipment that plugs into this cabling has its own overviews: the touchpads overview, the pushbuttons overview, the relay take-off platforms overview and the external-speakers overview.
History and development¶
The difficulty of wiring a pool was recognised early. A patent filed in 1977 by SSIH, then the Swiss holding company behind Omega, sets out the problem in numbers: if every starting device, touchpad and hand button has its own wire back to the timer, a ten-lane pool needs at least 31 conductors when the devices share one common wire, and sixty when they cannot, and every one of the connectors has to stay watertight.4 The patent’s answer was a single two-wire cable along the deck with a small electronic module at each lane. Each device was given an address code, the timer sent timing pulses down the line, and a module signalled a touch by pulling the line during its device’s slot. The same cable powered the modules.4
Both approaches stayed in use. The Colorado Time Systems (CTS) on-deck harness that served the System 6 console was still described in its manual as a multi-conductor cable, plugged into the console with a 50-pin connector.56 Daktronics and Swiss Timing built their harnesses as chains of lane modules, closer to the 1977 design: the OmniSport 2000 chains one module per lane and joins the chain to the console with a four-pin plug, and the Quantum Aquatics timer reads a chain of addressed modules over a powered data bus.27 CTS moved to a networked design with its Gen7 Serial Timer, whose deck plates and serial harnesses are nodes on a powered bus and can report what is plugged into them.89
On-deck harnesses¶
An on-deck harness, also called a mobile harness or a cable harness, is a portable cable laid beside the pool on the deck, with a place at each lane for that lane’s equipment to plug in. It needs no construction work, so it suits pools without in-deck wiring and temporary pools, and it can stand in when fixed wiring fails. One Ontario club’s setup notes for a pool timed with an ARES 21 describe that arrangement: a fixed deck harness for normal use, and a portable harness of six junction boxes chained together and run to the console if the fixed wiring breaks.10 The cost is loose cable on a wet deck, which Daktronics advises routing away from foot traffic and covering with a mat.2
The three main manufacturers build their harnesses differently:
- Colorado Time Systems cable harness: a multi-conductor cable with a pod at each lane. On a System 6 the touchpads and the first backup button plug into a primary harness, and the second and third buttons into a separate B and C backup-button harness. Near- and far-end harnesses have their own inputs on the console, and a second set of inputs allows a backup timer to be connected.5 The Gen7 Serial uses serial harnesses instead, which can be linked end to end so that one console takes a primary harness and a backup harness across as many as 20 lanes.8
- Daktronics lane module: every module is identical and can go in any lane. Each has jacks for a touchpad and three buttons and a lane cable to the next module, and the console works out which lane a module is from where it sits in the chain. A lane extension cable of 25, 50, 100 or 200 ft (7.6, 15.2, 30.5 or 61 m) joins the nearest module to the console. Daktronics points out that a failed lane can be fixed by swapping its module rather than replacing the whole harness.2
- Quantum Mobile Harness: one Swiss Timing module per lane, its case printed with a lane number that is also stored in the module. Up to ten modules chain from one cable at each pool end, with a terminator plugged into the last.11
In-deck systems¶
An in-deck system takes the cable off the deck. Conduit runs under the deck between junction boxes: those set into the deck are called deck boxes, those in or on a wall are wall boxes, and each carries a connection plate.2 During a meet the only loose cables are the short leads from each touchpad, button or platform to the plate beside its lane, and the console’s cables to the wall plate.
Deck plates¶
A deck plate is set flush into the deck at each lane, usually under or beside the starting block, and carries the jacks for that lane’s equipment. CTS places the deck box under the block’s platform, between the end wall and the block legs, and asks for 3 in of clear space around it. With a two-legged block the box is centred both side to side, halfway between the legs, and front to back, halfway from the coping to them; with a single-post block it is centred front to back in the same way and lined up with the post’s mounting plate.112 Each CTS plate arrives pre-wired with up to 200 ft (61 m) of cable and potted, and is screwed to the tile over a 4 × 4 × 6 in (10.2 × 10.2 × 15.2 cm) PVC box. The finished floor must sit level with the box’s top edge to within a quarter of an inch.1 At the two outside lanes the plates also take the start-system connection.1
Each manufacturer lays out the plate differently:
- CTS has made three styles. The standard plate is a connection hub screwed over the deck box. The QuickConnect deck plate moves the hub onto the starting block and leaves only a military-style connector in the deck, joined to the hub by one short cable. CTS requires it for relay platforms with speedlights.113 The Titanium Deckplate has titanium jacks on a domed top so that water runs off between the contacts, and it can replace the older 7.5 in square DP-7. It comes in a passive version and an intelligent version for the Gen7 Serial bus.14158
- Daktronics deck plates come in three kinds. A lane plate has jacks for the touchpad, three buttons, a lane speaker and a remote strobe. A start plate serves the horn start and the auxiliary speaker. Bulkhead plates come in pairs: the deck carries one and the bulkhead the other, and jumper cables link the two. The lane cables end at a lane interface behind the wall plate.216
- Swiss Timing deck plates are 153 mm square. Each carries jacks for a touchpad, a relay platform, three buttons and loudspeakers, wired for both a primary and a secondary timer. The same plate serves as a lane plate or a start plate.3
Conduit and wiring¶
The conduit sizes limit how many deck boxes one run can serve. The two editions of CTS’s architectural guidelines agree that a 2 in run can take up to 12 boxes, but disagree on smaller conduit. The System 6 edition allows four boxes on a 1 in run. The later Gen7 Legacy edition allows four on 1.5 in and only two on 1 in, and it also recommends draining the conduit.112 The Gen7 Legacy edition’s conduit drawing shows why the limit falls with the conduit size: each plate’s cable runs the whole way back to the wall box, so eight boxes on one 2 in run put eight cables in it, and smaller conduit is split into more runs, two of four boxes on 1.5 in and four of two on 1 in.12 This page treats the later edition, the more conservative of the two, as current. CTS keeps all in-deck wiring under 5 V, grounded at the console.1 Swiss Timing asks for ducts at least 75 mm across. That leaves room for twenty lane cables of 6.3 mm plus four cables of 4 × 0.5 mm², the load it expects on the last duct into the timing room of a ten-lane pool timed by two finish systems. For the lane runs it recommends shielded, untwisted control cable of 6 × 0.5 mm².3
Bulkheads need their wiring planned when they are built. CTS asks architects to have the bulkhead manufacturer provide conduit and boxes, and accepts a cable tray above the water line as an alternative.1
Wall plates and distribution boxes¶
At the other end of the conduit the cabling ends at a panel where the console connects. CTS uses a wall plate: a 15 × 15 in (38.1 × 38.1 cm) aluminium panel, pre-wired, set flush into a 12 × 12 × 6 in (30.5 × 30.5 × 15.2 cm) box 18–36 in (45.7–91.4 cm) above the floor. It also takes the scoreboard, start system, speaker and microphone, and diving judging terminal connections.1 Daktronics makes several wall plates, including single-ended and double-ended versions.2 Swiss Timing terminates each deck plate’s cable in an ODB10-SW distribution box in the timing room. The box holds up to four racks: primary and secondary for the finish end and for the far end.173
How the timer identifies each lane¶
The console has to know which lane every signal came from. The designs differ:
| Design | How the lane is identified | Example |
|---|---|---|
| Multi-conductor harness or plate wiring | The conductors the signal arrives on | CTS System 6 cable harness and legacy deck plates5 |
| Chain of identical modules | The module’s position in the chain | Daktronics lane modules2 |
| Chain of addressed modules | A lane number stored in each module, mapped to a lane in software | Swiss Timing Quantum Mobile Harness and ODB10-SW circuits1819 |
| Networked nodes | Node identity, mapped near-end and far-end in the console’s setup | CTS Gen7 Serial deck plates and harnesses8 |
The addressed designs let the operator reassign lanes. Quantum’s pool setup can, for example, make modules 3 and 5 act as lanes 1 and 2 so that two swimmers can race in the central lanes.18 The networked CTS deck plates also check what is plugged in. A Gen7 Serial deck plate recognises the type of device in each jack and flags missing or mismatched inputs, and it measures the current through each speedlight. This works only on in-deck systems, not on harnesses.8 CTS’s patent on this describes the plate sending a voltage step into the attached device and matching the response against stored signatures.9
The start system plugs in at a different point in each design. On a CTS System 6 it goes into a start connector on the primary harness.5 A Daktronics console on an on-deck chain takes the start cable directly, and an in-deck system adds a start-location deck plate for the horn start and the auxiliary speakers.2 A Swiss Timing Quantum timer has its own START1 and START2 inputs.7 On the Gen7 Serial bus the starter has a node of its own. CTS makes separate nodes for the timer, the starter, the scoreboard and the bulkheads, each keyed and colour-coded so that a cable fits only the node meant for it; see the Gen7 serial connect hubs.820
Connectors¶
Lane equipment plugs in with banana plugs, usually a dual plug with a ground side. Daktronics puts a tab on the ground side of the plug, and that side goes into the black jack. A touchpad plugged in the wrong way round can register touches nobody made.2 Banana plugs are not keyed, so CTS’s detection patent notes that a touchpad can end up in a speaker jack.9 Each manufacturer labels its jacks so that devices go in the right place:
- CTS deck plates have TOUCHPAD, BUTTON A (RJP), BUTTON B and BUTTON C. The harness pods have PRIME and BUTTON.21
- Daktronics lane modules have TOUCHPAD and BUTTON 1–3, and its lane deck plates have TP and B1–B3. On both, a relay platform shares the third button jack.2
- Swiss Timing uses colours: yellow for the touchpad, white for the starting block and red for a pushbutton.11
Care and maintenance¶
CTS names corroded connectors as the most common cabling fault.5 The manufacturers’ advice is broadly the same: keep the contacts greased and clean, and keep pool water off them.
- CTS: put dielectric grease in each harness or deck-plate jack before use, so that a little is pushed out when a plug goes in. After use, clean each jack with isopropyl alcohol and a cotton pipe cleaner, rinse with fresh water, and grease it again. Hang harnesses up to dry instead of bagging them. Diluted lime-scale remover is kept for badly scaled jacks and plugs, and CTS forbids it on wall plates, speedlight connectors and the 50-pin console connectors.6 The titanium plate needs only a check for debris before each use.22 An unused QuickConnect plate gets a terminator plug if some plates are in use, to stop electrolysis between its contacts, and a cover plug otherwise.13
- Daktronics: at each setup and teardown, brush any corrosion off the connections and coat the plugs with silicone lubricant.2
- Swiss Timing: pot each deck plate’s terminations in resin, seal the plate to the floor with silicone, and keep silicone paste on the external contacts. Plugging in wipes the paste off, so it has to be reapplied after each competition. Plates and harness modules are cleaned and regreased weekly and after every use.318
Each manufacturer also has a way to test the cabling before a meet. CTS’s test meter plugs into each jack and should read 4.5–5 V.21 The OmniSport 2000 has a lane-module test that shows each touch and button press by lane.2 The Quantum software lights each module green once it is communicating.18
Governing-body requirements¶
The rules state what the wiring must achieve, not how it is built. World Aquatics asks that automatic officiating equipment leave no exposed wires on the deck where that is possible. It also requires each lane’s equipment to be connected independently, so that one lane can be controlled and maintained without affecting the others.23 The NCAA rule on automatic timing equipment adds a note that pools should have conduit below the deck for the wiring of starting, timing and judging equipment.24
Products¶
The deck-cabling articles on this wiki are listed below, grouped by manufacturer. Each page covers the product itself, and this page is the shared overview they refer back to.
| Article | Manufacturer | Type | Installation |
|---|---|---|---|
| SWT3 swim terminal | ALGE-Timing | Bus lane terminal | On-deck |
| SWT swim terminal | ALGE-Timing | Bus lane terminal of the SWIM 2000 | On-deck |
| S4-SWIM lane box | ALGE-Timing | Eight-lane switch box of the Timer S4 | On-deck |
| FIN1 finish adapter | ALGE-Timing | Two-lane adapter for the S4-SWIM | On-deck |
| Cable 078 | ALGE-Timing | Cable from the S4-SWIM to each FIN1 | On-deck |
| MC8 push-button cable | ALGE-Timing | Eight-lane push-button cable for the Timy | On-deck |
| SWIM-FIX | ALGE-Timing | Under-deck box of the Timer S4 system | In-deck |
| ALGE swimming cable sets | ALGE-Timing | Terminal and speaker cable sets | On-deck |
| Colorado Time Systems cable harness | Colorado Time Systems | Multi-conductor lane harness | On-deck |
| Gen7 Serial cable harness | Colorado Time Systems | Serial lane harness | On-deck |
| QuickConnect deck plate | Colorado Time Systems | Deck connector and block-mounted hub (discontinued) | In-deck |
| Titanium Deckplate | Colorado Time Systems | Deck plate (passive and intelligent) | In-deck |
| DP-7 deck plate | Colorado Time Systems | Deck plate | In-deck |
| Gen7 serial connect hubs | Colorado Time Systems | Bus connection hubs | In-deck |
| Colorado Time Systems wall plate | Colorado Time Systems | Wall plate | In-deck |
| Wall plate cover | Colorado Time Systems | Lockable cover for a wall plate | In-deck |
| Daktronics lane module | Daktronics | Lane module harness | On-deck |
| Daktronics lane extension module | Daktronics | Harness lead to the console | On-deck |
| Daktronics deck plates | Daktronics | Deck plates | In-deck |
| Daktronics lane interface | Daktronics | Unit where the in-deck lane cables end | In-deck |
| Daktronics wall plate | Daktronics | Wall plate | In-deck |
| SST lane harness | Superior Swim Timing | Lane harness for 6, 8 or 10 lanes | On-deck |
| Quantum Mobile Harness | Swiss Timing | Addressed lane module harness | On-deck |
| Quantum harness cable | Swiss Timing | Harness-to-console cable | On-deck |
| Quantum harness terminator | Swiss Timing | Bus terminator | On-deck |
| PowerTime swimming harness | Swiss Timing | Pushbutton harness, one start and eight lanes | On-deck |
| Swiss Timing deck plate | Swiss Timing | Deck plate | In-deck |
| ODB10-SW | Swiss Timing | Distribution box | In-deck |
| ODB10 | Swiss Timing | ARES-era distribution box, discontinued | In-deck |
| Deckplate adapter | Swiss Timing | Tuchel adapter for a start deck plate | In-deck |
| Swiss Timing wall socket | Swiss Timing | Poolside wall socket | In-deck |
Related accessories¶
Items listed under swimming cables and accessories:
| Article | Manufacturer | Type | Installation |
|---|---|---|---|
| Quantum start cable | Swiss Timing | Box-to-timer start cable | In-deck |
See also¶
- Touchpads: the finish sensors this cabling carries
- Pushbuttons: the backup buttons on each lane
- Relay take-off platforms: the relay judging equipment on the blocks
- External speakers: the lane speakers wired through the same plates
- Timers: the timing consoles the cabling connects to
- Equipment: the equipment reference
References¶
Footnotes¶
-
Colorado Time Systems, Architectural Guidelines: A Guide for Designing Competitive Aquatic Facilities (deck plates and wall plates). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9
-
Daktronics, OmniSport 2000 Timing Console Operation Manual (ED-13312, Rev 16, 23 May 2019), deck cabling. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13
-
Swiss Timing, Swimming Concept: Quantum / OSB with footrest (0017.509.02, v4.9, January 2017). ↩ ↩2 ↩3 ↩4 ↩5
-
US Patent 4,156,870, Sports timing system (SSIH Management Services; filed 1977, granted 1979). ↩ ↩2
-
Colorado Time Systems, Swimming 6 for the System 6 Sports Timer Software User Guide (F870 Rev. 20241107), wiring systems. ↩ ↩2 ↩3 ↩4 ↩5
-
Colorado Time Systems, Cleaning Deck Plates, Cable Harnesses and Wall Plates (F897 Rev. 201111). ↩ ↩2
-
Swiss Timing, Quantum Concept Swimming User’s Manual (3480.508.02, v1.4, July 2015). ↩ ↩2
-
Colorado Time Systems, Gen7 Serial Timer User Guide (F1034). ↩ ↩2 ↩3 ↩4 ↩5 ↩6
-
US Patent 11,192,016 B2, Apparatus and method for the detection of timing components in swimming pools. ↩ ↩2 ↩3
-
Richmond Hill Aquatic Club, Timing system physical setup at Richvale (2025). ↩
-
Swiss Timing, Quantum Mobile Harness User’s Manual (3480.500.02, v1.1, August 2019). ↩ ↩2
-
Colorado Time Systems, Gen7 Legacy Architectural Guidelines (©2026), deck plates and conduit. ↩ ↩2 ↩3
-
Colorado Time Systems, Quick Connect Deck Plate Instructions (F881 Rev. 1204). ↩ ↩2
-
Colorado Time Systems, Titanium Deckplate (TDP) (titanium jacks, domed top, retrofit of DP-7 plates). ↩
-
US Patent 8,602,815 B2, Swimming pool deckplate for horizontal surfaces with integrated slopes around electrical contacts. ↩
-
Daktronics, T-7000 Series Touchpads Installation & Maintenance Manual (DD1953274) (lane interface troubleshooting). ↩
-
Swiss Timing, ODB10-SW User’s Manual (3494.501.02, v1.7, December 2018). ↩
-
Swiss Timing, Quantum-Swimming User’s Manual (3480.509.02, v1.4, October 2019). ↩ ↩2 ↩3 ↩4
-
Swiss Timing, Programmer AQ User’s Manual (3480.501.02, v1.1, January 2019). ↩
-
Colorado Time Systems, Gen7 Serial Connect Hubs (datasheet REV 09/22). ↩
-
Colorado Time Systems, Test Meter Instructions (F696 Rev. 0205) (harness-pod and deck-plate receptacle names). ↩ ↩2
-
Colorado Time Systems, Cleaning Wall Plates and Titanium Deck Plates (F1023 Rev. 201602). ↩
-
World Aquatics, Facilities Rules 2021–2025, FR 2.3.2.2 and FR 2.3.4.1. ↩
-
NCAA, Swimming and Diving Rules Book, Rule 1, Section 4, Art. 4 (note on below-deck conduit). ↩