Swiss Timing ODB10-SW
From Libre Aquatics Wiki, the free aquatics reference
The ODB10-SW is a Swiss Timing distribution box for fixed swimming-pool timing wiring. Mounted on the timing-room wall, it takes the cable from each lane’s in-deck plate and from the start plates, and passes the touchpad, starting-block and pushbutton signals to a Quantum Aquatics timer over two standard cables.1 Swiss Timing first issued its manual in December 2011. The box comes in Primary and Primary & Secondary versions for 6, 8 or 10 lanes.1
Role in the timing system¶
This section places the box in a Quantum installation; fixed and mobile deck cabling in general are covered in the deck cabling overview.
A Quantum pool is cabled one of two ways. A mobile installation lays a Quantum Mobile Harness along the deck. A fixed installation runs a cable from each Swiss Timing deck plate under the deck to the ODB10-SW.12 Swiss Timing describes the box as the centre of the fixed cabling, where the cables from the timer and from every deck plate meet.1 It places the box in the timing room. Its Swimming Concept guide credits it with faster fault-finding and switching of inputs and outputs, and with serving every aquatic discipline.2
Each box serves one end of the pool. A pool timed at the finish end only needs one box. A pool with touchpads at both ends uses a second box for the 25 m or 50 m end.1 Inside, a box holds a rack of harness circuits for the primary timer and, in the Primary & Secondary version, a second rack for the backup. A full installation therefore has up to four racks: primary and secondary at the finish (HA1), and primary and secondary at the far end (HA2).12
Design and construction¶
This section describes the box and its circuits.
The box is a rectangular case closed by a cover held with six screws.1 One end carries the two connectors to the timer: a 7-pin Tuchel socket marked HA for the harness data and a 4-pin Tuchel socket marked START. Beside them are cable glands for lanes 0 to 9 and for the start cable.1 Inside, each lane’s cable ends on a row of WAGO spring terminals marked B3, B2, B1, PF, TP, COM and SHIELD. These are the three pushbuttons, the platform, the touchpad, their common return, and the cable screen.1 Swiss Timing supplies a tool for opening the terminals, together with wall screws and washers.1
The lane signals reach the timer through harness circuits, part 3494.600, one per lane. Each
circuit stores its lane number. Swiss Timing programs the circuits for their lanes before
delivery, so they need reprogramming only when one is replaced.1 The Primary & Secondary
box carries a spare circuit in slot 11, marked RES.1 A circuit’s lane number is set with
an RFID programmer held within 1 cm of it. The ODB10-SW manual names programmer 3494.901,
sold with a spare circuit. The Programmer AQ, sets 3480.921 and
3480.922, does the same job, and its manual names ODB10-SW circuits. Neither manual says
whether the two are the same tool.13
The two documents give different case sizes. The 2018 manual gives 269 × 540 × 130 mm. The 2017 Swimming Concept guide gives 195 × 495 × 128 mm, with a smaller fixing pattern.12 The manual’s December 2018 revision records new pictures “with new case”, which probably accounts for the difference.1
Wiring¶
This section covers the cables on each side of the box.
Each lane deck plate has its own shielded cable of six 0.5 mm² cores, no more than 9 mm across, running to the box.1 Swiss Timing limits that run to 100 m.1 The plate’s contacts map to the box’s terminals one for one:1
| Signal | Deck plate | ODB10-SW |
|---|---|---|
| Button 3 | 3a | B3 |
| Button 2 | 2a | B2 |
| Button 1 | 1a | B1 |
| Platform | Pa | PF |
| Touchpad | Ta | TP |
| Common | c | COM |
| Cable screen | none | SHIELD |
The start deck plates carry the start signal from a start system such as the StartTime V and a ready signal, each as a pair, on terminals 1 to 4. The same four terminals appear on the matching wall socket.1 The manual also shows the lane loudspeakers wired in two groups, each fed by its own amplifier through a start deck plate.1
The box connects to the timer with two standard cables: 1865.010 for the start signal and
1892.010 for the harness data. The run from box to timer is limited to 200 m.1 The
7-pin HA connector carries separate +12 V supplies and data pairs for the primary and secondary
circuits. The 4-pin START connector carries the start and ready pairs.1 A Primary Quantum
takes the finish-end box on its HA1 and START 1 inputs and the far-end box on HA2 and START 2. A
Primary & Secondary Quantum has one harness input for each box.1
Swiss Timing’s Swimming Concept guide adds a rule for scoreboard cables that pass through the timing room. The cable screen is earthed at the scoreboard or at the ODB10-SW, never at both. A matrix scoreboard’s cable ends on a separate distribution box for displays.2
Installation and mounting¶
This section covers fixing the box and the wall sockets.
The box is screwed to the timing-room wall, with at least 110 mm left clear below it for the cables.12 The installer removes the side panel, feeds each deck-plate cable through a gland, strips it, and pushes the cores into the spring terminals with the supplied tool.1 The Swimming Concept guide places the timing room according to World Aquatics rules and suggests raising its floor by 30–35 cm so the operators can see the pool.2
Some signals are taken out to the poolside through surface-mounted wall sockets of cast
aluminium. They come with one or two plugs, in 4-pole and 7-pole, male and female
combinations; see Swiss Timing wall socket.1 The manual’s
deck-plate drawing labels the lane plate 3494.603. The Swimming Concept guide gives the same
plate as 3493.603.12
Care and maintenance¶
This section covers upkeep of the box and the plates it serves.
Swiss Timing says the box itself needs no preventive maintenance. A faulty harness circuit is
replaced and, if necessary, reprogrammed.1 The box is stored clean and dry.1 The
deck plates need more care. Between meets the Quantum is switched off and disconnected. The
banana plugs of the touchpads, pushbuttons, relay platforms and other peripherals are greased,
and the plate terminals are filled with silicone grease 9038.7047.1
Specifications¶
| Manufacturer | Swiss Timing, Corgémont, Switzerland1 |
| Lanes | 6, 8 or 10 (lanes 0–9)1 |
| Racks | Up to four per installation: HA1 and HA2, each primary and secondary12 |
| Lane terminals | WAGO spring terminals: B3, B2, B1, PF, TP, COM, SHIELD1 |
| Lane cable | Shielded, 6 × 0.5 mm², 9 mm maximum diameter; 100 m maximum1 |
| Timer connectors | Tuchel 7-pin (HA), Tuchel 4-pin (START)1 |
| Box to timer | 200 m maximum1 |
| Dimensions | 269 × 540 × 130 mm (2018 manual); 195 × 495 × 128 mm (2017 concept guide)12 |
| Weight | 3.350 kg (Primary, 10 lanes); 3.690 kg (Primary & Secondary, 10 lanes)1 |
| Clearance below | 110 mm minimum1 |
| Operating temperature | 0 to +45 °C1 |
| Storage temperature | −10 to +60 °C1 |
Part numbers and accessories¶
This section lists the parts Swiss Timing names.
| Part | Description |
|---|---|
3494.716 | ODB10-SW Primary, 6 lanes1 |
3494.718 | ODB10-SW Primary, 8 lanes1 |
3494.710 | ODB10-SW Primary, 10 lanes1 |
3494.728 | ODB10-SW Primary & Secondary, 8 lanes1 |
3494.720 | ODB10-SW Primary & Secondary, 10 lanes1 |
3494.600 | Harness circuit, one per lane1 |
3494.901 | Programmer for harness circuits, with a spare circuit1 |
1865.010 | Quantum start cable, box to timer1 |
1892.010 | Quantum harness cable, box to timer1 |
9071.3003 | Tool for the WAGO terminals, supplied1 |
9038.7047 | Silicone grease for plugs and deck plates1 |
2650.619, 2650.646, 2650.648, 2650.651, 2650.749, 2650.750 | Wall sockets1 |
An earlier Swiss Timing box sold as the ODB10, for the ARES timer, is a different product. A distributor lists it as discontinued, at 60 × 40 × 23.5 cm and 13–16 kg.4
See also¶
- Swiss Timing deck plate: the in-deck plate wired to the box
- Quantum Mobile Harness: the on-deck alternative to fixed cabling
- Programmer AQ: the tool that sets a circuit’s lane number
- Quantum Aquatics: the timer the box feeds
- Deck cabling: the deck cabling overview
- Swiss Timing: the manufacturer
- Equipment: the equipment reference
References¶
Footnotes¶
-
Swiss Timing, ODB10-SW User’s Manual (3494.501.02, v1.7, December 2018). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34 ↩35 ↩36 ↩37 ↩38 ↩39 ↩40 ↩41 ↩42 ↩43 ↩44 ↩45 ↩46 ↩47 ↩48 ↩49 ↩50 ↩51 ↩52 ↩53 ↩54
-
Swiss Timing, Swimming Concept: Quantum / OSB with footrest (0017.509.02, v4.9, January 2017). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10
-
AVK Group, Distribution box ODB10 (distributor listing, October 2026). ↩
Last updated October 7, 2026.