WTN, the Wireless Timing Network, is the radio system that ALGE-Timing
uses in place of timing cables. It works in the 2.4 GHz band and carries timing impulses,
display-board data and serial data to a PC over the same link.12 The radio is
built into the Timy3 timer and into ALGE’s radio push buttons, photocells, start
devices and display-board receivers. A stand-alone WTN unit adds it to older ALGE timers
over a cable.13 ALGE describes the network as a mesh in which every device both
sends and receives and can pass on messages for the others.41
See the timers overview for the shared background on timing consoles.
Role in the timing system¶
A WTN network takes over the jobs that cables do in a wired ALGE system. A photocell or push button sends its impulse to the timer by radio, and the running time goes back out over the same link to a display board and to the results PC.25 In swimming, ALGE uses it for its radio semi-automatic package, in which each lane’s timekeeper holds a radio push button instead of a cabled one, and for diving scoring, in which each judge enters marks on a Timy3 W.6
Network design¶
Two or more WTN-series devices make a network, and a device that cannot reach another directly can reach it through a third. The 2017 catalogue says this lets each device act as a repeater, so the network can reach beyond the range of a single link.12 The WTN manual gives two different limits on network size: 60 devices in its description and 32 in its section on the master unit.1
One device in each network is the master and keeps the others synchronized. It is the device with the lowest MAC address. If it drops out, for instance with a flat battery, the rest choose a new master, and the first impulse sent during the changeover is lost.1 A new device joining also forces a resynchronization. Impulses triggered while it runs are held and sent once it ends, tagged with their delay.1 With a Timy3 in the network, the Timy3 is both master and time server, so ALGE advises switching it on first and not cycling it during a competition; a restart can lose impulses for up to five minutes while the network settles.7
Every impulse reaches the timer 0.1 s after it was triggered, a fixed delay that the timer can subtract to recover the true time of day. The manual gives the tolerance on that delay as ±0.0001 s in one section and ±0.0002 s in two others.1 The Timy3 corrects the delay automatically for its own radio; a Timy or Timy2 on an external unit must have the correction switched on, and marks corrected times with a “t”.17 An impulse that a device fails to confirm is re-sent with its delay attached, and reaches a cabled timer over the RS485 line of its connecting cable. After 90 seconds without confirmation the silent device is dropped from the network.1
Teams, frequencies and power¶
Networks are separated by team. There are 15 teams: nine single teams, 1–9, each on its own frequency, and six joint teams, A–F, that share a frequency. Joint-team devices can relay one another’s traffic but ignore each other’s data, which ALGE intends for neighbouring venues such as two show-jumping rings.13 Devices without a display, such as the push button and the display-board receiver, set their team on a 16-position rotary switch whose position 0 is a factory test mode.89 The WTN manual advises against running adjacent single teams such as 1S and 2S side by side, because their frequencies interfere.1
Sources count the radio settings differently. The WTN and Timy3 manuals, the WTN leaflets and the BANG2 documents give 16 frequencies or 16 teams. The 2017 catalogue, the Timy3 leaflet, the product pages and the device manuals’ team sections give 15.171025 Fifteen is the number of teams a user can choose; the device manuals show 16 switch positions, one of them the factory test setting.89
Transmit power is 10, 25, 50 or 100 mW. The factory setting is 10 mW, which the manuals give as the European limit, against 100 mW in the United States.13 At 10 mW the range is about 350 m in line of sight.1 The BANG2 manual and leaflet give its radio about 300 m instead.10 The e-Start and e-Start W manuals state that WTN works in the 4.2 GHz band, which does not match the 2.4 GHz given in every other ALGE source.3
Devices¶
This section lists the devices ALGE names as members of the WTN series.
| Device | Role |
|---|---|
WTN | Stand-alone unit with display, keypad and three AA cells; links a timer, display board, photocell or PC to the network14 |
| Timy3 W and WP | Timer with the radio built in; module off by default7 |
WTN-PB | Radio push button8 |
WTN-DB | Receiver that clips to an ALGE display board and is powered by it9 |
WTN-WS | Radio link for an anemometer and its display board (athletics)5 |
PR1aW | Photocell with the radio built in2 |
| E-START W | Electronic start device with flash3 |
| BANG W, BANG CW and BANG2 | Start speaker systems with the radio built in210 |
USB-WTN | USB adapter, first made to link a WTN unit to a PC11 |
The stand-alone unit connects to a Timy, Timy2, TdC 8000 or TdC 8001 timer over
a 25-pin cable, 280-03 or 280-09, which carries timing channels 0–4, display-board data and the
RS485 line for late impulses.1 The Timy3 manual says a Timy2 with an external unit works
almost like a Timy3, with two differences: the Timy3 can switch its module off to save power, and
on the Timy2 the radio impulses also appear on the banana sockets.7
Operation¶
Each device sends on one of five channels, C0–C4. ALGE assigns C0 to the start, C1 to the
finish and the rest to intermediate times, or to a second start and finish.1 For lane
timing the Timy3 has a socket mode, in which each radio button is registered in turn and given its
own channel, up to nine. Times taken this way carry a “t” prefix.712 The TrackTimer guide calls for socket mode from four lanes upward. It
adds that the E-START W cannot be registered this way and always stays in standard mode.12
Settings made on one device spread to the others. A baud-rate change on a WTN unit applies to
every device then in the network, and the display-board receiver can only have its baud rate and
power set this way.19 Firmware follows the same path. One unit is updated from a
PC over cable 283-02 and then sends the update by radio to every device in its team. The Timy3
does the same from its own menu, which the Timy3 manual says takes up to 20 minutes in one section
and 15–45 minutes in another.17 Timy3 units can also synchronize their clocks with
one another over the network, once or every minute.7
Use in swimming and diving¶
In ALGE’s radio semi-automatic swimming system each of up to eight lanes has a
WTN-PB, and the start comes from an
E-START W to a BANG2 speaker and the
Timy3 WP. A D-LINE board takes its data through a
WTN-DB.613 The wired alternative uses the
MC8 cable. A recaller can also use a WTN-PB to send a false start
to the BANG2 by radio.10
For diving, ALGE’s 2017 and 2026 catalogues describe a scoring system that gives every judge a
Timy3 W, with the marks sent over WTN to a results PC through a WTN unit and a USB-WTN
adapter.26 The 2026 catalogue’s water polo system also lists a WTN and a
WTN-PB.6
History¶
ALGE’s firmware history for “the WTN family” begins with version 13.33 of 15 March 2013, but its
June 2013 entry already refers to new WTN hardware, so the system is older than the log. ALGE has
not published a launch date.14 The log records the first WTN-PB firmware in March
2014. It adds BANG2 support in 2019 and support for a “WTN2 system” in March 2022, which ALGE’s
pages do not otherwise describe.14 The WTN, WTN-PB and WTN-DB manuals carry a European
declaration of conformity dated 12 November 2016.189
Specifications¶
| Band | 2.4 GHz |
| Frequencies and teams | 16 radio frequencies; 15 teams (nine single, six joint) |
| Transmit power | 10, 25, 50 or 100 mW; 10 mW factory setting |
| Range | About 350 m in line of sight (about 300 m in BANG2 documents) |
| Timing channels | Five per device (C0–C4); up to nine in Timy3 socket mode |
| Radio delay | 0.1 s fixed, corrected by the timer |
| Network size | 60 or 32 devices (the manual gives both) |
Stand-alone WTN unit | 80 × 140 × 40 mm, 360 g; three AA cells (alkaline or NiMH) or 8–24 VDC |
Battery life, WTN unit | 15–70 h depending on power, temperature and traffic |
Interfaces, WTN unit | RS232 2400–115,200 baud; display board 2400–19,200 baud; RS485 at 38,400 baud |
Part numbers and accessories¶
This section lists the parts ALGE sells for the network.
| Part | Description |
|---|---|
WTN | Stand-alone radio unit4 |
WTN-PB | Radio push button8 |
WTN-DB | Display-board receiver9 |
WTN-WS | Anemometer radio link5 |
USB-WTN | USB adapter11 |
WTN-SET1, WTN-SET2 | Training sets with a Timy3 W or WP and two PR1aW photocells2 |
280-03, 280-09 | 25-pin cable, WTN unit to timer (3 m, 9 m)1 |
283-02 | WTN unit to PC serial port, 2 m1 |
284-02 | WTN unit to display board, powering the unit from the board, 2 m1 |
SPB1 | Bracket with hook-and-loop strap1 |
PS12A | Mains power supply1 |
See also¶
- Timy: the timer with the radio built in
- MC8 push-button cable: the wired alternative for semi-automatic timing
- WTN-PB: the radio push button
- Timers: the timers overview
- ALGE-Timing: the manufacturer
- Equipment: the equipment reference
References¶
Footnotes¶
-
ALGE-Timing, Wireless Timing Network WTN manual (Version E26-02-18). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26
-
ALGE-Timing, The Sports Timing Experts (general catalogue, 2017), pp. 10–16, 24, 30, 35–36, 93 and 108. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8
-
ALGE-Timing, e-Start W manual (Version E23-10-31), 1.1 and 2.3. ↩ ↩2 ↩3 ↩4 ↩5
-
ALGE-Timing, WTN (product page, as of November 2026). ↩ ↩2 ↩3
-
ALGE-Timing, Aquatic Sports (catalogue, June 2026), pp. 3, 17 and 18. ↩ ↩2 ↩3 ↩4
-
ALGE-Timing, Timy3 General (version E25-03-10), 4.5, 6, 9.3, 9.9 and 11. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8
-
ALGE-Timing, Wireless Timing Network Push Button manual (Version E23-11-02). ↩ ↩2 ↩3 ↩4 ↩5
-
ALGE-Timing, Wireless Timing Network for Display Boards manual (Version E23-11-02). ↩ ↩2 ↩3 ↩4 ↩5 ↩6
-
ALGE-Timing, Speaker System BANG2 manual (Version E23-11-14), 2.7 and 6.3. ↩ ↩2 ↩3 ↩4
-
ALGE-Timing, USB-WTN manual (Version E200228). ↩ ↩2
-
ALGE-Timing, Timy TrackTimer (version E23-11-02), section 4. ↩ ↩2
-
ALGE-Swim USA, Systems (US distributor). ↩
-
ALGE-Timing, Changes for the WTN Family (firmware history, 2013–2023). ↩ ↩2
Last updated November 11, 2026.