Libre Aquatics Wiki

Swiss Timing ARES 21

From Libre Aquatics Wiki, the free aquatics reference

ARES 21 is a swim timing system made by Omega Electronics and, from 2005, by Swiss Timing. It has two parts: the IF-ARES, an interface box on deck that time-stamps every contact from the pool, and a PC running the ARES Swimming program, which receives those contacts over an RS-232 cable and does all of the race processing.12 Swiss Timing dates ARES to 1995.3 It was succeeded by Quantum Aquatics, which keeps the same split between box and computer.4

Models and naming

This section covers the names used for the system and its parts.

ARES is an acronym. The 2002 manual spells it out as Advanced Result Entry Station; Swiss Timing’s company history gives both “Advanced Results Entry Station” and “Automatic Recording Evaluation System”.53 Neither the manuals nor Swiss Timing’s history explain the number 21.

The documents use several names for the parts. ARES 21 is the system and, on the datasheets, the interface box itself, article number 3330.900. The manuals call the same box the IF-ARES and call the PC program ARES Swimming (also ARES-Swimming).12 The box runs a sport module that the PC loads into it at start-up; swimming is one module, and Swiss Timing sold separate programs for diving and synchronized diving, synchronized swimming and water polo, plus a suite containing all of them.12

The 2002 edition of the manual is branded “a product of Omega Electronics, Switzerland”. In August 2005 the Swatch Group moved Omega Electronics’ sports business into Swiss Timing, and the 2008 edition carries Swiss Timing’s name with otherwise the same chapters.561

Role in the timing system

This section places ARES 21 in a swimming installation; the shared background on timing consoles is on the timers overview.

The IF-ARES sits between the pool and the computer. Each lane’s touchpad, relay take-off platform and backup pushbutton connect to a lane module on a harness, and up to two harnesses plug into the box, one at each end of the pool. A start system such as the StartTime II feeds the start input.127 The box records each contact with a code for its source and holds it in an internal buffer; result lists, records, printouts and scoreboard pages are all produced on the PC.2

Swiss Timing gives two consequences of that design. Because the PC keeps every race on its hard disk, earlier races can be recalled, reprinted or sent to the scoreboard again. Because the box buffers its data, timing continues while the PC is down and the data is processed once it is back.2

History and predecessors

This section traces ARES 21 from the Omega console before it to the Quantum system after it.

Omega’s earlier swimming console was the OSM6, a self-contained briefcase unit with its own keyboard, display and printer. ARES moved the processing from the console to a PC. It can also imitate the OSM6’s one-way serial results output, and Hy-Tek’s software reads an ARES in that mode through the same interface it uses for the OSM6.128

Swiss Timing’s history places ARES in 1995 and describes it as the point where its timing met information technology.3 The swimming manual appeared in May 2002 under the Omega Electronics name and again under Swiss Timing’s in April 2008; both editions describe ARES Swimming 2.04.51 A Swiss Timing notice of October 2001 explains how ARES measures relay take-overs and records that LEN approved the method in 1995 and FINA on 4 May 1998.9

Meet-management programs kept supporting ARES after Quantum arrived. Hy-Tek Meet Manager offers two ARES interfaces, and Splash Meet Manager added functions for ARES in 2007 and 2009 and was still fixing its ARES interface in 2016.81011 A 2016 setup guide from Central Victoria Swimming, an Australian district association, describes linking a Meet Manager computer to an ARES computer, which places the system in use there that year.12

Quantum’s manuals begin in 2012. The Quantum software still reads the ARES set of “Lst” text files for data handling, and later Swiss Timing starters and scoreboards name ARES beside Quantum as a compatible timer.41314

Design and hardware

This section describes the IF-ARES interface box.

The IF-ARES is a portable box measuring 410 × 285 × 80 mm and weighing 2.8 kg, which a Central Victoria Swimming guide describes as flat and red.212 A red LED on the front blinks while the swimming module is running.1 The box keeps a time base of 16 MHz and counts to 23:59:59.99 before starting over, at a resolution of whole seconds down to thousandths.2

It runs from an external 12 V battery pack rather than from the mains. Swiss Timing presents this as a security feature: with a notebook PC and a battery-powered printer, a meet can carry on through a power cut or be run from the poolside entirely.2 The Corgémont datasheet lists a single and a dual power supply, the dual one for an ARES 21 with a data switcher.2

The datasheets number ten connectors on the panel:215

ConnectorUse
HARNESS 1/2Swimming timing lines, one harness per input
LINE 1/2/3Serial inputs for diving and synchronized swimming
SCBScoreboard output
PCLink to the computer, RS-232
PRNPrinter output, RS-232
GPData handling, RS485
OMTChannel for an Omega judging console
SYNCTime synchronization input
STARTStart impulse input and READY lamp output
MAIN/BUMain and backup 12 V supply

The two datasheet editions disagree on the console that the OMT channel serves: the Corgémont edition calls it an Omega MTL, while the UK edition calls the channel MTS and the console MTO in its power table.215 The diving and judging hardware is covered on the judging terminals page.

A “protocol printer” can be connected straight to the box. It prints every event the box records as it happens, such as lane and time in swimming or judge and score in diving.21 The Swiss Timing datasheet also says that international patents cover the ARES concept, without naming them.2

Connectivity

This section covers the box’s links to the harness, the starter, the scoreboard and other computers.

Harness and starter

The pool-configuration screen tells the program which harnesses are connected, on which side of the pool, which one is on the near-end input HA1, and which end is the finish. Two more settings map the order of the lane modules along the harness to the lane numbers on the blocks, so a ten-lane harness can serve a pool run as eight central lanes. Presets cover eight lanes on an eight-lane harness and eight lanes on a ten-lane harness.1

On a Swiss Timing interface each lane has three contacts: touchpad, relay platform and backup button. The start contact can be set as normally open or normally closed, closed being standard for Swiss Timing start systems.1 A StartTime II or III connected to the box lights its green READY lamp only once the ARES has been cleared for a start, and can be set to refuse a start before that.716

Scoreboard

The SCB port always drives a 20 mA current loop, and can drive its RS485 pins as well.1 The program has two scoreboard types:

  • Galactica, Swiss Timing’s alphanumeric board, which also takes start lists sent from the record-output dialog in a mode called “GALACTICA Startlist”.1
  • ERTD, written for Daktronics boards controlled by Daktronics’ Venus software, which receive each heat’s start list when it is called up.1

In UNT4 modes an extra figure, such as a team score, can go on a twelfth line.1 The scoreboard can follow the race, show the results page by page with a hold time, show the time of day, or freeze the last result between events.1 A separate record-output function sends record and split comparisons (ahead of the start and of the finish, and after each intermediate) to a scoreboard or a television character generator; inputs on the box can trigger its Clear and Manual commands.1

Daktronics boards also accept its output. The SW-2000 manual gives one protocol setting for an “Omega Ares 21 or Quantum” and an address-configuration drawing for ARES, and a Daktronics support article sets the SW-2006 event and heat driver to address 11 for ARES 21 and 18 for Quantum.1718 Swiss Timing’s Calypso manuals list ARES as a compatible source.14

Data handling

From ARES Swimming 2.15, a meet-management computer can connect in either of two ways:1

  • To the ARES PC’s second serial port, by a null modem cable or a three-wire cable.
  • To the GP port on the IF-ARES itself, through an RS485 to RS-232 converter.

The manual gives the GP port as RS485, while Hy-Tek’s guides describe it as an RS422 port that needs an RS-232 to RS422 converter and recommend it only for long cable runs.18

The link runs in one of two modes. OSM6 mode copies the one-way output of the older OSM6 at 9600 baud, 7 data bits, even parity, 1 stop bit. Bi-directional mode runs at 9600 baud, 8 data bits, no parity, 1 stop bit.1 Hy-Tek adds that some ARES units in OSM6 mode also need the 8N1 setting.8 Swiss Timing offered the scoreboard and GP protocols, and new sport modules for the box, as free downloads.1

Software and operation

This section summarizes how a session is run in ARES Swimming.

Setting up

The manual advises a new data folder for each day of competition, so that a day’s results can be backed up by copying one folder. A new folder takes its tables and settings from the program’s default folder, and can copy the competitor and record tables from the previous day.1

The box should be synchronized every time it is switched on, because start impulses are stored as time of day and a backup system has to share the same clock. It can be set directly from the PC, on the next start impulse, or on an impulse at the SYNC input, and only once per power-on; an unsynchronized box sets itself to 0:00 at the first start.1 A test window then shows each lane number in large figures as its contact is pressed, shading the window’s edges to show which end of the pool it came from, so two people can check every contact before the session.1 The harness can also be switched off in software, so that scoreboard and data handling links can be tested while swimmers warm up.1

Program texts can be shown in English, French, German, Italian or Spanish, and the competition-definition texts and on-screen messages can be edited in plain text files.1

Running a race

Heats are grouped into competitions. Each competition carries an event number and round, which cannot be changed once it is saved, and a length, style and category from which the program works out how many laps to expect and which records apply. A scoreboard title line can pull in the event number, round, heat, category, length and style automatically.1 Start lists are built from a competitor table, in which a bib field can hold the number assigned by an outside results system.1

The race dialog shows each lane’s times, laps completed and arming state. With two harnesses it shows both ends, and the operator switches between them. Lanes arm themselves after an arming delay, and the operator can also force a lane on or off. There are two delays: the one after the start should be just under the fastest possible swim to the far end, and the one during the race just under the fastest possible swim there and back.1 A missing touch can be flagged by a blinking time. The operator can add or remove a lap, enter a finish time, or take the backup time for a lane, and can simulate a start or a touch from the keyboard.1 If the wrong heat was connected when the start went off, the race can be recovered from the events list, and results can be copied from one heat to another.1

The events dialog lists every time received, marking whether it came from a touchpad, a button or a take-off, and whether it was valid, invalidated or entered by hand. A received time cannot be altered, only replaced by validating another or adding a new one.1

Backup times and relays

With three backup buttons in a lane the middle time is the official backup, which the manual attributes to FINA rules. With a Daktronics interface, two buttons give their average and a single button gives its own time.1

For relays, the 2001 Swiss Timing notice describes ARES as storing every touchpad and block impulse. When a swimmer touches, it looks for the last block impulse within 2 seconds either side of the touch and reports the difference 2 seconds after the touch, with a minus sign when the next swimmer left early. The figure is the net take-over time, with no adjustment for the 0.03 s allowance.9 The allowance itself is covered on the relay take-off platforms overview.

Results and records

Records are kept at three levels, labelled for example world, European and national, and the labels can be renamed. The program compares each winner’s time with all three, marks a new record on the result, and offers to update the table; record split times are kept for comparison displays.1

Pressing End of race sends the result to whichever of these outputs is selected, normally only one:1

  • an HTML page through the PC’s web browser, or a plain text file, with or without a preview;
  • a text file in the data folder named from the event, round and heat (sEEERRHH.txt);
  • the ARES-Print program, the default, over a DDE link;
  • the ARES online printer connected to the box;
  • a line added to a results table file for import into a database.

Meet-management software

This section covers the two meet-management programs documented with ARES 21.

Hy-Tek Meet Manager offers an “Omega OSM6/ARES21” interface, in which the timer only sends, and an “Omega ARES21 Bi-Directional” interface, which requires ARES software 2.14 or later.819 In bi-directional mode Meet Manager tests the link when the port is opened, can send the meet’s events to ARES, and fetches each heat’s times on request, either by event and heat or by the timer’s own race number, which starts again at 1 whenever the timer is switched on.19 On the ARES side, a Meet Manager computer on the GP port can supply start lists, and ARES can pass Meet Manager’s start lists, finish lists and team scores to the scoreboard in ERTD mode.1

Central Victoria Swimming’s 2016 guide runs the ARES PC on one serial port to the timer and links it to the Meet Manager PC by a null modem cable and USB-serial adapters. It notes that Meet Manager sometimes failed to pick up times for events longer than 100 m, and gives a workaround: enter such events in ARES as 50 m races, since only the event number and lane times transfer.12

Splash Meet Manager lists Omega ARES 21 among its supported timers in its 2010 getting-started guide and its 2018 brochure. Its 2011 FAQ describes the ARES 21 link as bidirectional: the operator selects a heat and Splash asks the timer for that heat’s results.202122 Splash added sending event summaries and medals to ARES in September 2007, required ARES software 2.24d or later for its summary function from September 2009, and fixed reading of finals from ARES 21 in January 2016.1011

Compared with Quantum

This section sets out what Quantum Aquatics kept from ARES 21 and what it changed.

Both systems divide the work the same way: a box on deck time-stamps contacts and a PC program processes them. Both map harness modules to lanes on a pool-configuration screen and synchronize the box at the start of a session.14 Quantum’s data handling still includes the ARES file type and an OSM6 output.4 Its scoreboard settings keep a Swiss Timing alphanumeric feed for Galactica boards and an ERTD feed, and add a numeric Calypso output.4 Daktronics drives both from one protocol setting, but its event and heat driver needs a different address for each.1718

Specifications

This section lists the interface box’s published specifications.

SpecificationValue
Article number3330.900
PowerExternal battery, 10.8–14.4 V, nickel-cadmium or lead-acid
Current draw400 mA typical for the interface; 200 mA per swimming harness; 100 mA per judging console
Operating temperature0–45 °C
Relative humidity20–80%, non-condensing
Time capacity23:59:59.99, repeating
Resolution1, 1/10, 1/100 or 1/1000 s
Time base16 MHz; ±1 ppm over 0–45 °C; ageing ±5 ppm
Dimensions410 × 285 × 80 mm
Weight2.8 kg
PC linkRS-232
Data handlingGP port (RS485 per Swiss Timing, RS422 per Hy-Tek) or the PC’s second serial port; 9600 7E1 (OSM6 mode) or 9600 8N1 (bi-directional)
Scoreboard output20 mA current loop, optional RS485
ApprovalsCE; RoHS (Corgémont edition)

Sources: Swiss Timing datasheets and manual.2151

Part numbers and accessories

This section lists the options on the two datasheet editions.

Part numberItem
3330.900ARES 21 interface
3330.900.BTARES with aquatics interface and Bluetooth (Corgémont edition)
3330.901ARES with aquatics interface and Bluetooth (UK edition)
3330.621Single power supply
3330.624Dual power supply for ARES 21 and switcher (Corgémont edition only)
3330.701ARES data switcher
3397.902Laptop computer for ARES
3330.613Transport case
3330.630ARES online printer, with integrated battery (3330.630.US in the UK edition)
3330.661ARES online printer, 115/230 V
3330.633ARES diving and synchronized diving software
3330.634ARES synchronized swimming software
3330.635ARES water polo software
3330.636All ARES aquatics software
3330.650Scoreboard cable, 20 mA and RS485
3330.651ARES double start cable

Sources: Swiss Timing datasheets.215

See also

References

Footnotes

  1. Swiss Timing, Concept ARES 21 Swimming User’s Manual (3330.560.02, version 3.30, April 2008). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34 ↩35 ↩36 ↩37 ↩38

  2. Swiss Timing, ARES 21 Timing Device datasheet (3330.525.02.RA). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17

  3. Swiss Timing, Innovation milestones (1995, ARES). ↩ ↩2 ↩3

  4. Swiss Timing, Quantum-Swimming User’s Manual (3480.509.02, version 1.4, October 2019). ↩ ↩2 ↩3 ↩4 ↩5

  5. Omega Electronics, ARES Swimming user’s manual (3330-560-02, version 3.1, May 2002). ↩ ↩2 ↩3

  6. Swatch Group, Enhanced synergies in the non-watchmaking sector (5 August 2005). ↩

  7. Swiss Timing, StartTime II User’s Manual (document 3399.502.02, Version 2.1, July 2007). ↩ ↩2

  8. Hy-Tek, Meet Manager 8 guide, Omega OSM 6 or ARES 21. ↩ ↩2 ↩3 ↩4 ↩5

  9. Swiss Timing, Relay break detection in swimming (official communication 307.225, October 2001). ↩ ↩2

  10. Splash Software, Release notes (archived June 2010). ↩ ↩2

  11. Swim Wiki, Meet Manager: Release Notes. ↩ ↩2

  12. Central Victoria Swimming, Setting up the computers to run a swim meet (July 2016). ↩ ↩2 ↩3

  13. Swiss Timing, StartTime IV E-Gun User’s Manual (3481.501.02). ↩

  14. Swiss Timing, Calypso 8-digit LED Scoreboard User’s Manual (3403.500, version 2.2, August 2016). ↩ ↩2

  15. Swiss Timing, Ares 21 timing device datasheet, UK edition (3300.525.02C). ↩ ↩2 ↩3 ↩4

  16. Swiss Timing, StartTime III User’s Manual (document 3399.504.02). ↩

  17. Daktronics, SW-2000 Series 10” Numeric Digit Display Manual (ED-12156, Rev 14, May 2015). ↩ ↩2

  18. Daktronics, Quantum timer not showing Event/Heat data on Address 11 (KB DD3844000). ↩ ↩2

  19. Hy-Tek, Interfacing with the Ares 21. ↩ ↩2

  20. Splash Software, Meet Manager 11: How to Start (GeoLogix AG, May 2010). ↩

  21. Splash Software, Splash Meet Manager (product brochure, April 2018). ↩

  22. Splash Software, Splash Meet Manager 11 FAQ (October 2011). ↩

Last updated October 8, 2026.