Libre Aquatics Wiki

SynchroMM

From Libre Aquatics Wiki, the free aquatics reference

SynchroMM is a Windows program from Colorado Time Systems (CTS) for scoring synchronized swimming, the sport now called artistic swimming. It collects the judges’ awards from CTS wireless judging terminals, or takes them typed in, calculates figure and routine scores, and sends the results to a CTS scoreboard.12 CTS sold it under part number R-8700-0159, alone or in a package with scoreboards and wireless adapters.1 As of 2026 CTS lists the product as discontinued.3

Naming

CTS has used several names for the program. Its 2013 sheet calls it Wireless Synchro, and its judging and adapter guides write Wireless Synchro MM, Synchro MM and SynchroMM.245 After the sport was renamed, CTS relabeled it Artistic Swimming Meet Management Software and kept SynchroMM in brackets.13 The part numbers did not change.21

System components

This section lists the parts of a SynchroMM installation. A complete system has four parts: the program on a laptop, a wireless interface box (WIO-003) cabled to the laptop by USB, one wireless judging terminal (WJT-003) per judge, and a scoreboard.26 CTS advises one or two spare terminals and, optionally, a spare interface.1 The judging guides cover both the 900 MHz and 2.4 GHz generations of the terminals, and the program works with either.46

The SYNCHRO-03 package adds two portable scoreboards with the cables to join them, two wireless scoreboard adapters and one copy of the program. A caddy or stand for the boards is ordered separately.1 The sources differ on which adapter the package holds. The 2023 datasheet names the WA-2, the current product page names its successor, the WA-3, and the 2013 sheet does not name a model.132

CTS’s requirements also changed over time. The 2013 sheet asks for Microsoft .NET Framework 4.0 on Windows XP Service Pack 3 or later. The 2023 datasheet lists Windows Vista, Windows 7 or later. The product page lists all three and says the framework is included.213

Scoring and operation

This section covers how the program runs a meet. According to CTS, the program follows the order of a meet and handles both figures and routines. Figures judged at several stations can be combined into one result, and routine scores are calculated for both technical and free routines.1 Judges’ awards come from the terminals or can be entered at the laptop.21

The program controls the wireless interface. The operator sets the radio channel in the program, and each terminal is set to match.46 During a routine each terminal shows the routine number, the judge’s number and which score it expects next. A judge who has sent a score can ask to change it. SynchroMM, like the System 6 console, supports that request, while the older System 5 console does not.4 For simultaneous events, each event uses its own laptop and interface on a separate channel, at least six channels apart at 900 MHz and two at 2.4 GHz.46 The judging guides leave troubleshooting to the SynchroMM operator rather than the judges.4

Other features CTS lists are reports, a judges’ evaluation module and meet data transfer.1 A medal count, aggregate totals, and start lists and results for both routines and figures can be printed or saved as PDF files. Meet data can be exported from one meet and imported into the next, and the program reads files from CTS’s earlier DOS synchro program.1

Scoreboard and video display output

This section covers how results reach a display. CTS says SynchroMM can send scores to any CTS aquatic scoreboard, either by cable or through a wireless scoreboard adapter.1 Each generation of adapter guide describes the laptop link:

AdapterLaptop connectionSource
WA-1 (Sky-Fi)Cable R-0002-0428 and USB-to-serial adapter 015-467, both ordered separately7
WA-2USB cable R-015-2038
WA-3USB cable R-015-6065

With the WA-2 and WA-3, the laptop assigns the adapter a COM port, which the operator then selects in SynchroMM, and both adapters in the pair are set with configuration switch 8 up.85 The scoreboards show three scoring components (execution, impression and difficulty), with the routine number and the total score.1

For video and matrix boards, DisplayLink Plus can take synchro data from up to four CTS sources at once, each a laptop running SynchroMM or a CTS sports console, through its timer COM ports. The routine order with team and athlete names can be imported as a text or XML file exported from SynchroMM. Each laptop can run its own event, such as one at each end of the pool.9 CTS describes SynchroMM as the only software guaranteed to work with its scoreboards.1

Rule support

This section covers which competition rules the program follows. CTS states support for the 2013 rules of the international federation and the 2014 rules of the US national body. That support covers penalties, figure descriptions and degrees of difficulty.1 The 2023 datasheet calls those bodies World Aquatics and USA Artistic Swimming. In 2013 and 2014 those bodies were still FINA and USA Synchro, so the datasheet applies their later names to the older rule sets.1

The current World Aquatics rules judge routines differently from the three components that SynchroMM displays. Routines now go to two panels of five judges, one for elements and one for artistic impression, while technical controllers check each team’s predeclared difficulty against a coach card.10 No CTS source says that SynchroMM was updated for this structure.

Compared with console scoring

This section sets SynchroMM beside the other ways CTS and Daktronics have scored the sport. CTS earlier scored synchro on its timing consoles. The System 5 program, from 1998, handled both figures and routines. The 2004 System 6 program covers routines only, with technical and artistic scores, rankings, and optional wired judging consoles through an interface box.1112 SynchroMM runs on a PC instead, covers both figures and routines, and takes its scores from the wireless terminals.14 Daktronics took a similar approach with OmniSport Pro Synchro, a Windows program that scores the sport through its OmniSport 2000 console.

CTS’s 2011 catalogue lists the wireless synchro software and terminals together, and describes CTS as “the Official Scoring System of USA Synchro”.13

See also

References

Footnotes

  1. Colorado Time Systems, Artistic Swimming (SynchroMM) datasheet (Rev 05/23). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18

  2. Colorado Time Systems, Wireless Synchro product sheet (revised 09/13). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7

  3. Colorado Time Systems, Artistic Swimming (product page, marked discontinued). ↩ ↩2 ↩3 ↩4

  4. Colorado Time Systems, Wireless Judging 900 MHz User Guide (F941) (Rev 20110720). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7

  5. Colorado Time Systems, 2.4 GHz Wireless Adapter WA-3 User Guide (F1045). ↩ ↩2 ↩3

  6. Colorado Time Systems, Wireless Judging 2.4 GHz User Guide (F961) (Rev 201106). ↩ ↩2 ↩3 ↩4

  7. Colorado Time Systems, Sky-Fi Wireless Adapter (WA-1) User Instructions (F929, Rev 201401). ↩

  8. Colorado Time Systems, Wireless Scoreboard Adapter WA-2 User Guide (F987, Rev 201605). ↩ ↩2

  9. Colorado Time Systems, DisplayLink Plus help, Synchronized Swimming. ↩

  10. World Aquatics, Competition Regulations, Part Seven, 5.5 and 6.5–6.6. ↩

  11. Colorado Time Systems, Synchronized Swimming for the System 5 Sports Timer (F511, Rev 0698). ↩

  12. Colorado Time Systems, Synchronized Swimming for the System 6 Sports Timer (F874, Rev 0604). ↩

  13. Colorado Time Systems, Complete Timing, Scoring, Training and Display Solutions catalogue (2011), page 13. ↩

Last updated September 30, 2026.