Libre Aquatics Wiki

ALGE E-START

From Libre Aquatics Wiki, the free aquatics reference

The E-START is a hand-held electronic starting device made by ALGE-Timing of Lustenau, Austria. It has a push button and a flash of four high-power LEDs. Pressing the button fires the flash and sends a start impulse to the timing equipment.1 ALGE makes it in two models: the E-START, which connects by a fixed cable, and the E-START W, which carries its own radio and battery.12 ALGE sells it as a replacement for the starting pistol in athletics, cycling and skating as well as swimming. Its own literature calls it an electronic start gun.345 In ALGE’s swimming systems the cabled model plugs into the SU3 start unit at the starter’s position.67

See the start-systems overview for the shared background that applies to every start system, including the rules on visual start signals.

Naming and product line

This section covers the two models and the dates found for them. ALGE writes the name both as E-START and as e-Start. The radio model carries a W suffix, as do other ALGE devices that use its WTN radio network.15 The cabled model’s declaration of conformity is dated 12 July 2014, the earliest date found for either model.1 ALGE’s athletics start-devices brochure of November 2015 lists both models.3 The radio model’s declaration is dated November 2016. It cites radio standards published in 2015, so it is probably a later re-declaration rather than a launch date.2

ALGE’s 2013 swimming catalogue does not list the E-START. Its system drawings show a separate start flash next to the SU start unit.8 The E-START appears in the declaration of conformity of the TM-SWIM system manual, and it is drawn in the TM-SWIM system in ALGE’s 2026 aquatics catalogue.96 ALGE does not say whether the E-START replaced the earlier flash.

The current English manuals for both models are version E23-10-31, from October 2023, and a German edition of the cabled manual has the same date.1210 The radio model’s manual records one change in use: its automatic switch-off after 35 minutes without a trigger has been disabled since November 2017.2

Design and hardware

The E-START is a flat hand-held unit. On its face are the four-LED flash, a status LED and the push button that triggers the start.1 ALGE rates both models for use from −20 to 45 °C.12

The cabled model has no battery or switch. Its 2 m cable ends in a DIN plug, and the unit takes its power through that cable from the device it is plugged into.1 The radio model adds a second LED for radio signal strength, a rotary team switch set with a small screwdriver, a charging socket for ALGE’s PS12A power supply and a built-in lithium-ion battery. It cannot be connected by cable.211

ALGE’s documents give four sizes and several weights. The two manuals, the 2015 brochure and the 2017 catalogue give 265 × 150 × 35 mm for both models. The TM-SWIM system manual gives 150 × 250 × 35 mm, and the product pages give 300 × 175 × 45 mm for the cabled model and 295 × 175 × 30 mm for the radio model.12349511 The cabled model weighs about 0.3 kg in the manuals and catalogues and 328 g on its product page.195 For the radio model the figures are 0.5 kg in the brochure and catalogue, about 0.4 kg in its manual and 278 g on the product page. The manual also gives 1.1 lb, which is the 0.5 kg figure, so its kilogram value is probably the error.34211

Operation

This section describes how the device is used and how the timer must be set for it. Pressing the button sends an impulse on the start channel, C0, and fires the flash at the same moment. A second press within five seconds sends another impulse and makes the flash strobe three times in quick succession as a false-start signal.12 Whether the timer records that second impulse depends on the delay set for its start channel, which is the time a channel ignores further impulses after one has arrived. According to ALGE’s manuals, a short delay is needed for the false-start signal to register (0.1 second is their example), and one of five seconds or more prevents it.1 The Timy3 sets the start-channel delay to 1.00 second by default.12 On ALGE’s BANG speaker systems the same five-second rule produces a gunshot sound for the first press and a false-start sound for the second.34

The cabled model turns on as soon as it is plugged in. Its status LED blinks green when it is ready, orange when the timing device is not signalling that it is ready, and red when the start line is shorted. The orange indication works only through an SU3.1

The radio model is switched on by holding the button until the status LED turns from red to green, and off by holding it for about five seconds.2 All WTN devices that are to work together need the same team number, set on each unit’s switch. The switch has nine separate teams, which use different radio frequencies, and six joint teams, which share one.2 The radio model sends on C0 by default and can be set to C1 to C4 by holding the button at switch-on and counting further presses; a ten-second hold at switch-on resets it to C0.2 After a press, its status LED shows the battery level as green, orange or red, and the radio LED indicates how strong the signal is from the nearest WTN device.2

Radio timing in ALGE’s WTN network carries a fixed transmission delay of 0.1 second, which the Timy3 removes automatically from times it receives. To pass a radio time on to other equipment as an electrical impulse, a Timy3 channel must be set to the E-START W correction.12 ALGE’s TrackTimer manual adds that the radio model cannot be configured as a WTN socket device and always runs in standard mode, which ALGE says keeps BANG speakers triggering correctly.13

Use in swimming

ALGE’s 2026 aquatics catalogue draws the E-START in three swimming systems:6

SystemStart equipment shown
Fully automatic pool systemE-START on an SU3, with a FLASH XL, all connected to a TM-SWIM
Open-water finishE-START and SU3 with a Timy Timy3 WP, an MC9 and a BANG2 speaker
Semi-automatic radio systemE-START W with a BANG2, a radio headset and a Timy3 WP

The catalogue says the flash allows more exact hand timing and lets swimmers with a hearing impairment see the start.6 ALGE’s 2017 catalogue makes the same two points for athletes in general.4 The start tone in ALGE’s pool systems comes from the TM-SWIM through the lane speakers, not from the E-START.9

Connections

The cabled model’s DIN plug carries four signals:1

PinSignal
1Start impulse, channel C0
2Ready status from the timing device
3Ground
4Supply in, 6–12 V DC
5Not used

The start output is an open-collector transistor that pulls the line low, rated at no more than 14 V, 100 mA and 250 mW. The host must supply at least 450 mA.1 The SU3’s socket for a start device uses the same assignment for pins 1 to 4 and supplies 11 V on pin 4.7 The TM-SWIM system manual describes the E-START as powered from the TM-SWIM at 12 V, which in that system reaches it through the SU3.97

The cabled manual lists the devices that can power it: the Timy, Timy2 and Timy3 (only when the Timy itself runs from an external supply), the SU2 and SU3 start units (passing power on from the timing device), BANG speakers, and several ALGE athletics and photo-finish devices.1 ALGE’s 2015 brochure also lists the Timer S4 as compatible.3

The radio model works with any device on ALGE’s WTN network, including the Timy3 W and WP timers, the WTN radio unit and BANG W speakers.2 Its radio settings are:23

SettingValue
Band2.4 GHz
Teams15 (9 separate, 6 joint); 16 frequencies in the specification tables
Output power10 mW as delivered; up to 100 mW, set only from a WTN unit or a Timy3
Timing channelsC0 (start, default), C1 (finish), C2, C3, C4
RangeAbout 350 m in line of sight

The manual notes that 10 mW is the maximum allowed in the EU and 100 mW in the United States.2 The count of radio settings differs between ALGE’s documents: the radio manual’s team switch and the 2017 catalogue give 15, while the manual’s own specification table and the 2015 brochure give 16.243 Both manuals also state in their general notes that WTN works at 4.2 GHz, which conflicts with the 2.4 GHz given in their specifications and in every other ALGE document.12

Specifications

SpecificationE-STARTE-START W
Flash4 high-power LEDs4 high-power LEDs
ConnectionFixed 2 m cable, DIN plugWTN radio, 2.4 GHz
Start outputOpen collector, active low; max. 14 V, 100 mA, 250 mWRadio impulse, channel C0–C4
Power6–12 V DC from host, at least 450 mALi-Ion battery, 3.6 V / 10.4 Wh, built in
ChargingNot applicableAbout 4 hours with PS12A, at 0–45 °C
Running timeNot applicableAbout 45 hours at 22 °C, 23 hours at −20 °C (one impulse per minute)
Operating temperature−20–45 °C−20–45 °C
Dimensions265 × 150 × 35 mm (manual)265 × 150 × 35 mm (manual)
WeightAbout 0.3 kg (manual); 328 g (product page)About 0.4 kg (manual); 0.5 kg (catalogues); 278 g (product page)

Figures are from the two manuals unless marked; see Design and hardware for the other sizes ALGE gives.12511

Part numbers and accessories

This section lists the E-START’s companion parts that have articles here.511

ItemPart numberArticle
Electronic starting device, cableE-STARTThis article
Electronic starting device, radioE-START WThis article
Power supply and charger for E-START WPS12APS12A
Start unitSU3SU3
Speaker start systemBANG2BANG
Connection cable199-20Swimming cable sets
Radio networkWTNWTN

See also

References

Footnotes

  1. ALGE-Timing, e-Start manual (Version E23-10-31). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18

  2. ALGE-Timing, e-Start W manual (Version E23-10-31). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19

  3. ALGE-Timing, Start Devices for Track and Field (V1510.1, 2015). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8

  4. ALGE-Timing, The Sports Timing Experts (general catalogue, 2017). ↩ ↩2 ↩3 ↩4 ↩5 ↩6

  5. ALGE-Timing, E-START (product page, as of November 2026). ↩ ↩2 ↩3 ↩4 ↩5 ↩6

  6. ALGE-Timing, Aquatic Sports (catalogue, June 2026). ↩ ↩2 ↩3 ↩4

  7. ALGE-Timing, Start Unit SU3 manual (Version E-23-11-02), 6.1.1. ↩ ↩2 ↩3

  8. ALGE-Timing, The Specialist for Swimming (catalogue V1.113, 2013). ↩

  9. ALGE-Timing, Swimming Timing System Manual (Version E24-08-29), 5.8. ↩ ↩2 ↩3 ↩4 ↩5

  10. ALGE-Timing, e-Start Bedienungsanleitung (Version D23-10-31; in German). ↩

  11. ALGE-Timing, E-START W (product page, as of November 2026). ↩ ↩2 ↩3 ↩4 ↩5

  12. ALGE-Timing, Timy3 General (version E25-03-10), 9.3.1. ↩ ↩2

  13. ALGE-Timing, Timy TrackTimer (version E23-11-02). ↩

Last updated November 8, 2026.