Libre Aquatics Wiki

Colorado Time Systems Gen7 serial connect hubs

From Libre Aquatics Wiki, the free aquatics reference

The Gen7 serial connect hubs are the connection points of the in-deck system that serves the Gen7 Serial Timer made by Colorado Time Systems (CTS). Each hub is a node on the system’s serial bus. There is a separate hub for the timer, the start system, the scoreboard and the bulkheads, and each is keyed and colour-coded so that only its own cable fits.1 Most are set into the deck as TDPI- parts, but the same nodes can also be built into a Gen7 wall plate; the starter’s wall-plate node is WPI-S2.23 CTS calls the bus an “intelligent” system, and its patent covers the networked-node design.14

Role in the timing system

This section places the hubs in a Gen7 Serial installation. On an older, parallel-wired CTS in-deck system, each lane’s deck plate has its own cable back to one wall plate, and the timer, the start system and the scoreboard all connect there.56 On a Gen7 Serial system the lane wiring ends instead at the Titanium Deckplate in each lane, which is itself a node on the bus, and the timer, start system, scoreboard and bulkheads each plug into a hub of their own wherever the facility put one.27 CTS’s presentation of the system says the bus lets the facility choose those places, including points for deck clocks and portable scoreboards.8

Which nodes make up a course is set when the system is installed, and the timer’s software then offers those course setups; adding a new one needs CTS support.9 CTS’s patent on the system describes each node as carrying an identifier and a stored position measured from a corner of the pool, so that the timer can draw the pool, let the operator pick the nodes for an event and hand a replacement node the position of the one it replaced.4

See the deck cabling overview for the background shared by every deck plate and harness, including how other systems identify each lane.

Hub types

This section lists the hubs by job. Each one is told apart by the colour of the collar round its socket and by the key that stops the wrong cable going in.1

HubPart numberColourWhat plugs in
Timer connectTDPI-T1RedThe timer’s in-deck cable, which carries timing and scoreboard data910
Starter connectTDPI-S2 (WPI-S2 in a wall plate)GreenThe start system, with its lane-speaker audio3
Scoreboard connectTDPI-SC5Light grayScoreboard equipment only, such as deck clocks and portable scoreboards118
Bulkhead connect, in-deckTDPI-BH3BlueThe deck end of a bulkhead link1
Bulkhead connect, on bulkheadTDPI-BH4BlueThe bulkhead end of the same link1

The datasheet photograph shows one plate of each colour, so it does not say whether the two bulkhead parts differ in colour.1 It calls the scoreboard hub gray, while CTS’s video calls it light gray to set it apart from a dark gray Lane Quick Connect hub.8 That sixth hub has the same housing and features as the others, but it is missing from the datasheet and the product page, and CTS has not published its part number or said what plugs into it.112

In the deck and in wall plates

This section covers where the hubs can be mounted. The TDPI- parts are in-deck nodes. Each is a floor plate fitted to a 4 × 4 × 6 in PVC junction box, the same box size CTS uses for its deck plates, and the boxes are joined by 1.5 in PVC conduit.15 Outdoors, CTS offers these floor plates in place of the older deck “tombstones”.2

The same node types can instead be mounted in a wall plate. CTS lists the timer, start, scoreboard and bulkhead hubs as mountable in the deck or in wallplates, and the Gen7 Serial Timer manual allows for the timer node to sit in either place.29 The Championship Elite manual gives the starter’s two versions by number: TDPI-S2 in the deck and WPI-S2 in a wall plate.3 No other WPI- number has been published, so the wall-plate versions of the timer, scoreboard and bulkhead nodes are presumed but not confirmed. CTS’s patent treats wall plates the same way, as one kind of node on the bus.4

Only the Gen7 wall plate can hold nodes. CTS describes it as a “smart” plate with LED indicators that show the system’s status, and an office version lets the timer stay in a locked room rather than at the timing table.27 CTS’s earlier aluminium wall plate is a parallel-wired panel. It has fixed sockets for short-course, near-end and far-end timing, start, speaker, scoreboard and judging terminals, and no nodes.6 A start system reaches one of those through a CMP-WPxx cable instead of the Gen7 starter cable.3

Design and construction

All of the hubs share one housing. Each is a square plate fixed with four corner screws, with “GEN7” moulded at the top and the CTS name down one side. Radial ribs surround a round multi-pin socket in the centre, whose collar carries the hub’s colour, and a notch below the socket lines up the plug.18 The pins are titanium, and CTS says they carry no current while nothing is plugged in.111 CTS describes the connector as wet-pluggable, meaning that mating the plug pushes water off the contacts, so a bulkhead connection no longer has to be kept dry.18 When nothing is plugged in, a screw-on cap, supplied with the hub, closes the socket.2

CTS has not published the pin count, the plate’s dimensions or the hubs’ weight.

Detection and diagnostics

This section covers what the hubs report. According to CTS, each hub checks twice a second whether something is connected at its location, reports on its input connections, its wire terminations and any corrosion, and keeps troubleshooting data in on-board memory.212 These are CTS’s descriptions, and no independent test of them has been found.

The results appear on the timer’s diagnostics screen, which treats the in-deck wiring and the on-deck harnesses alike. Before a test, any bulkheads and harnesses are plugged into the right deckplate, wall plate or timer connection. With the pool empty every input should read open, and a walk round the deck pressing each pad, button and relay platform should turn each one closed; an input that reads shorted or corroded points to water or oxide in that part of the wiring. The start input can be tested at the near end, at the far end and on the timer itself.9

A separate CTS patent describes one way to identify connected equipment: a processor sends a voltage step into the device and compares the response with stored signatures.13 CTS has not said whether the hubs use that method.

Connection to the timer

This section covers the cables. The timer reaches the bus through one cable, R-015-715-xx. Its black end goes into the timer’s in-deck socket and its white end, with a red key, into a timer node in the deck or a wall plate.9 CTS’s quick start guide labels this run the in-deck timing and scoreboard connection, and shows a direct cable from the timer to a scoreboard only as an option.10

The start system has two routes. It can be wired straight to the timer, with one cable for the start signal and one for the speaker, or it can plug into a starter node through R-015-706-xx, which has a green key.9 On the Championship Elite that cable runs from the starter’s WALLPLATE connector, comes in 8 m and 15 m lengths, and carries both the start signal and the audio for the lane speakers into the deck.3

Scoreboard data travels the same way. The timer sends it onto the bus through its in-deck cable, and the scoreboard hub is the point on the bus reserved for scoreboard equipment.1011 One kind of scoreboard equipment is the computer running CTS’s DisplayLink Plus (DL+) software for an LED video board, which takes the Gen7 timer’s RS-485 scoreboard data. That link also lets the board show names, team totals and full results sent by the timer, so the DL+ computer needs no connection of its own to the meet-management software.9

A movable bulkhead connects through a pair of hubs: TDPI-BH4 on the bulkhead and TDPI-BH3 in the deck beside it.1 CTS’s video presents this as the end of keeping bulkhead plugs dry.8

Care and maintenance

CTS’s instructions for the hubs are short. Debris is removed from the socket, no chemical cleaner is used, and the cap goes back on when the hub is not in use; the floor plates can be power-washed.212 CTS describes the hubs as needing almost no maintenance.1 The Gen7 Serial Timer manual disagrees in part. Its general cleaning steps for cable and in-deck connectors call for rubbing alcohol and silicone grease, without saying whether the hubs are excluded.9 This article follows the hub documents as the more specific source.

Specifications

ManufacturerColorado Time Systems, Loveland, Colorado
Part numberTDPI-T1, TDPI-S2, TDPI-BH3, TDPI-BH4, TDPI-SC5; WPI-S213
TimerGen7 Serial Timer
ConnectorKeyed, colour-coded, wet-pluggable multi-pin socket; titanium pins1
ColoursTimer red; starter green; scoreboard light gray; bulkhead blue18
MountingIn the deck over a 4 × 4 × 6 in PVC junction box, or in a Gen7 wall plate12
Conduit1.5 in PVC between boxes1
MonitoringConnection check twice a second; on-board memory (CTS)2
Timer cableR-015-715-xx9
Starter cableR-015-706-xx, 8 m or 15 m3
PatentUS 10,137,353 (filed 2015, granted 2018)4
Earliest dated documentDatasheet, REV 09/22

Part numbers and accessories

This section lists the hubs and the parts used with them.

  • TDPI-T1, timer connect.1
  • TDPI-S2, starter connect, in the deck; WPI-S2, the same node in a wall plate.13
  • TDPI-BH3, bulkhead connect in the deck; TDPI-BH4, bulkhead connect on the bulkhead.1
  • TDPI-SC5, scoreboard connect.1
  • Connect hub cover, the cap for an unused hub; no part number published.1
  • R-015-715-xx, timer to timer node.9
  • R-015-706-xx, start system to starter node, 8 m or 15 m.3
  • CMP-WPxx, the cable a start system uses on an older parallel wall plate instead.3

See also

References

Footnotes

  1. Colorado Time Systems, Gen7 Serial Connect Hubs (datasheet REV 09/22). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23

  2. Colorado Time Systems, Gen7 Serial Swim Timing (datasheet REV 10/24 and product page). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10

  3. Colorado Time Systems, Championship Elite Start System User Instructions (F1064), connections. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10

  4. US Patent 10,137,353 B2, System for timing and scoring aquatic sports in pools (filed 2015, granted 2018). ↩ ↩2 ↩3 ↩4

  5. Colorado Time Systems, Gen7 Legacy Architectural Guidelines (©2026), deck plates, conduit and wall box. ↩ ↩2

  6. Colorado Time Systems, Universal Wallplate (product page and Universal Wall Plates sheet, Rev 03/14). ↩ ↩2

  7. Colorado Time Systems, Serial or Legacy, Which Gen7 Timer is Right for You?. ↩ ↩2

  8. Colorado Time Systems, Gen7 Serial Swim Timing (video, 3:15), connect hub slides. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7

  9. Colorado Time Systems, Gen7 Serial Timer User Guide (F1034 Rev 202603), connections and diagnostics. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10

  10. Colorado Time Systems, Gen7 Serial Quick Start Guide (F1041 Rev C). ↩ ↩2 ↩3

  11. Colorado Time Systems, Gen7 Serial Scoreboard Connect Hub (datasheet REV 09/22). ↩ ↩2 ↩3

  12. Colorado Time Systems, Gen7 Swim Timing Serial Connect Hubs (product page). ↩ ↩2 ↩3

  13. US Patent 11,192,016 B2, Apparatus and method for the detection of timing components in swimming pools (priority 2014). ↩

Last updated October 16, 2026.