Libre Aquatics Wiki

ALGE SWR 2 relay take-off pad

From Libre Aquatics Wiki, the free aquatics reference

The SWR 2 is a relay take-off pad made by ALGE-Timing for starting blocks that have no sensor of their own. It is a 500 × 500 mm stainless-steel plate, 20 mm thick, that sits on top of an existing block and registers the moment the outgoing relay swimmer leaves it.1 ALGE offered it with the SWIM 2000 system from at least 2002 and still listed it in its 2013 swimming catalogue. The 2017 catalogue lists the SWR7 in its place.231

See the relay take-off platforms overview for the shared background that applies to every relay take-off device.

Role in the timing system

At a relay changeover the timing system sets the incoming swimmer’s touchpad time against the instant the outgoing swimmer breaks contact with the block. A block with no sensor cannot report that moment, so the SWR 2 adds one. ALGE’s own SO 2 block had the sensor built in, and the SWIM 2000 documents treat the two as alternatives for the same socket.23 According to the 2013 catalogue the pad can time a relay changeover, the moment a starter leaves the block, or a reaction to the start signal.1

ALGE’s 2002 guideline describes the pad as a mobile detector for competition only, to be taken off the block again before the pool opens to the public. The SO 2, by contrast, could stay in place.2

Design and construction

The pad is a flat plate of surface-treated stainless steel, grade 1.4571. It has a non-slip top surface of ALGE’s own design, which the 2013 catalogue says does not wear or change over years of use.1 ALGE’s photographs show a plain grey plate lettered ALGE-TIMING in two corners.21 Both the 2002 brochure and the 2013 catalogue say that other sizes and designs could be made to order.31 No source gives its weight or describes how the sensor inside works.

Mounting

The two ALGE sources describe mounting differently. The 2002 architectural guideline says the pad fits almost any existing block through a choice of mounting options, and its photograph shows four small holes in the plate.2 The 2013 catalogue says the pad is held on with lashing straps supplied with it, so that the block needs no screws or other preparation. Its photograph shows the plate tied onto a block with two straps.1

Connection to the timer

In the SWIM 2000 system each lane end has an SWT swim terminal with five timing channels: one touchpad, up to three push buttons, and one starting block, which is either an SO 2 or an SWR 2.3 The 2013 catalogue adds that the newer SWT2 terminal can also measure how long the swimmer’s feet stay in contact as they leave the block.1

The SWIM 2000 software handles the relay channel the same way for either device. Before the start signal it treats the channel closing as the event, which lets it take a training reaction time once the load on the block passes 5 kg. After the start it treats the channel opening, the swimmer leaving the block, as the take-off.4 An early take-off sets off a repeated beep in the officials’ headset. The software also marks any take-off more than a set tolerance early in red. ALGE recommends a tolerance of −0.03 s, citing its own and other makers’ comparisons with high-speed video, and the marking does not change the recorded time.4

Models and naming

This section lists the names ALGE and its distributors have used for screw-on and strap-on relay pads.

NameSourceMounting
SWR1, also SWD1ALGE SWIM 2000 component page (archived January 2001); Split Second TimingScrewed onto the block; quartz-sand top
SWR 22002 brochure and guideline; 2013 catalogue p. 8Several mounting options (2002)
SWR22013 catalogue p. 10Lashing straps, no screws
SWR7, SWR7M2017 catalogue onwardScrews (SWR7) or strap (SWR7M)

The 2001 page uses both SWR1 and SWD1 for one pad, and ALGE’s Australian distributor still lists the SWR1 as a screw-on plate for existing blocks.56 No source says whether the SWR 2 replaced the SWR1 or whether the SWR7 replaced the SWR 2. The sequence of catalogues suggests both changes, but it is inferred rather than stated.

Compared with the SWR7

The SWR 2 is a 20 mm plate, 500 mm square.1 The SWR7 is a full platform of 740 × 560 × 40 mm that weighs 20–26 kg depending on the source; its article gives the sources. The SWR7 comes in a screw-mounted version and a strap-mounted SWR7M, so it keeps both of the mounting methods that ALGE’s documents give for the SWR 2.

Specifications

MaterialStainless steel 1.4571, surface treated
Dimensions500 × 500 × 20 mm
WeightNot stated
MountingSeveral options (2002); lashing straps, no screws (2013)
MeasuresRelay exchange, block-off and reaction times
ConnectionStarting-block socket of an SWT or SWT2 terminal
RulesALGE states compliance with the FINA, SSCH, AAU, NCAA and LEN rules1

Part numbers and accessories

This section lists the pad and the devices ALGE names alongside it.

PartDescription
SWR 2Relay take-off pad for existing blocks1
SO 2Starting block with the sensor built in, the alternative to the pad2
SWT, SWT2Lane terminals with a starting-block socket31
SWR1Earlier screw-on relay pad6

See also

References

Footnotes

  1. ALGE-Timing, The Specialist for Swimming (catalogue V1.113, 2013), pp. 8 and 10. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12

  2. ALGE, SWIM2000 Architectural Guidelines (Version E-02-01-24), sections 5.1 and 6. ↩ ↩2 ↩3 ↩4 ↩5 ↩6

  3. ALGE, SWIM2000 (brochure, 2002; Split Second Timing copy). ↩ ↩2 ↩3 ↩4 ↩5

  4. ALGE-Timing, SWIM2000 Manual (Version E-020222, 2002; archived), 3.3 and 3.11.1. ↩ ↩2

  5. ALGE-Timing, Components of the SWIM 2000 System (archived January 2001). ↩

  6. Split Second Timing, Relay pad (ALGE Australia; undated). ↩ ↩2

Last updated November 12, 2026.