Libre Aquatics Wiki

ALGE SWIM 2000

From Libre Aquatics Wiki, the free aquatics reference

The SWIM 2000 is a swimming timing system made by ALGE-Timing of Lustenau, Austria, and run from a Windows PC.1 Its centre is the SWC controller, which keeps the time and stores every impulse. SWT lane terminals, chained on one bus cable at each end of the pool, report touchpads, push buttons and starting blocks to it.23 ALGE listed the system by October 2000 and documented it in a manual, a brochure and an architectural guideline in 2002.45 Hy-Tek Meet Manager and Splash Meet Manager both kept interfaces for it.67

Role in the timing system

This section describes how the parts of the system divide the work. The SWC sits at the timing desk. It talks to the timing PC over RS232 and to the lane terminals over two RS485 buses, one for the start end and one for the turn end, and it drives the display board and a protocol printer.3 ALGE describes the PC software as the display and keyboard for the SWC: the timing itself happens inside the controller, which runs on its own battery and keeps every time if the PC fails.51

Each lane has one SWT at each end where touchpads are used. A terminal takes one touchpad, up to three 023-02 push buttons and one relay take-off sensor, either an SO 2 starting block or an SWR 2 pad fitted to an existing block. Each lane therefore has five separate timing inputs at either end.2

The starter works from the SU start unit, which has a start button and a microphone for announcements over the lane speakers. A Q34 headset plugged into the SU lets the starter talk to the system operator, and a switch chooses between the two uses.3 The SWC has its own amplifier for the speaker line.1

History and predecessors

This section covers what the dated sources show about when the system was sold. The earliest dated trace is a calibration certificate. The Neuchâtel astronomical and chronometric observatory checked SWC serial number 9913001 for ALGE on 16 March 1999, over twenty one-hour intervals, and at the 20-hour mark the controller read 19 h 59 min 59.9958 s. ALGE printed the certificate in its architectural guideline as an independent accuracy test.8

ALGE’s German product list of October 2000 names the SWIM 2000 next to the Timer S4 swimming system, so the two were offered side by side.4 An English page captured in January 2001 introduces the SWIM 2000 as a new system for the start of the coming swim season. It says the system could also serve water polo, diving and synchronized swimming.1 The English manual is version E-020222, from February 2002, and ALGE’s guideline for architects is version E-02-01-24.58 In that guideline ALGE calls the SWIM 2000 the first timing system able to work over a network with meet-management and other software, a claim made by ALGE alone.8

By October 2007 ALGE’s swimming page offered the Timy PXE as its semi-automatic package and the TM-SWIM TimeManager as its fully automatic system, and it no longer listed the SWIM 2000.9 The TM-SWIM firmware page warns against loading its firmware onto “the old SWC”.10 The TM-SWIM keeps the same layout of chained lane terminals, a terminator on the last unit, and numbered 200 and 201 cables for terminals and speakers. This suggests the TM-SWIM succeeded it, though no ALGE document found says so.510 No source gives a date when the SWIM 2000 was withdrawn.

Design and hardware

This section covers the controller and the lane terminals. The SWC takes its time base from a temperature-compensated crystal oscillator at 10.000 MHz and resolves to 1/10,000 s over a range of 23 h 59 min 59.9999 s.2 ALGE recommends returning it for calibration every three to five years.5 The controller holds its data in flash memory, and its display-board and video outputs are galvanically isolated. An internal 12 V gel cell backs up mains power at 100–240 V or an external 12–18 V DC supply; the brochure gives four hours of running without the PC.2

The front panel carries volume controls for the microphone, headset, audio input and overall level. Its buttons let the operator talk over the speakers, test the start line and fire a start by hand. Lamps show an error, external supply and charging.1112 In January 2003 ALGE’s FAQ for the system gave one known fault: speaker feedback after the start, cured by an SWC firmware update.13

The SWT terminals carry no lane number. All of them are identical, they are joined by a single cable from one to the next, and an SWT-END plug closes the last one.2 Each takes its power and its 1/10,000 s clock from the SWC.311 The German manual describes the terminals as fully waterproof.12 Because the units are not numbered, the software asks which end of the chain is lane 1. In the emergency mode, which uses ALGE’s default settings, a chain wired from the far lane comes out reversed, with lane 1 reported as lane 8.5

Connectivity

This section lists the SWC’s ports and how the rest of the system connects. The controller has four RS232 ports, all without parity, with 8 data bits and 1 stop bit, and three RS485 ports:25

PortUseSpeed
RS232Timing PC9600 baud (brochure, German manual); 38400 baud (English manual)
RS232, isolatedDisplay board2400 baud
RS232Protocol printer or third-party results software2400 baud
RS232, isolatedVideo interface9600 baud (brochure); 19200 baud default (English manual)
RS485Start-end timing bus
RS485Turn-end timing bus
RS485Display board

Only the English manual gives 38400 baud for the PC link. The brochure, ALGE’s 2001 web page and the German manual all give 9600.211125

The rear panel has sockets for the two timing buses, two printers, the PC, TV output, the display board (on a socket and on banana plugs), the SU, a start input on banana plugs, two active speakers, the headset, and audio line in and out.2 The manual’s diagrams show a 200-xx cable joining the terminals, a 201-xx cable joining the speakers, a 202-xx cable to the SU and a 067-02 cable to the timing PC. See ALGE swimming cable sets for the numbered cables.5 The speakers alternate between active SPA units, each with a gel cell and amplifier, and passive SPP units, with one SPA driving one SPP; see the SPA2 and SPP2 article for the later models.2

ALGE’s own displays for the system were GAZ4 boards with bistable electromagnetic seven-segment digits.8 The software can drive them with the running time on its own line or on the first free line, with lines ordered by lane or by rank, or with all results on a single line.5 For names and graphics ALGE offered custom dot-matrix boards and LED boards up to full-colour video walls.8

Software and operation

This section describes ALGE’s Windows software for the system. The package was free, but lists could be printed only after the user registered with ALGE and copied the licence file it sent into the program folder.5 The January 2001 page gives Windows 95, 98 or NT 4.0; the 2002 manual and brochure give Windows 95 to XP.152

The package has separate programs, so timing can run on one PC while results are prepared on others over the network.2 It contains:5

  • Timing-Manager, the timing program used with ALGE’s own SWIM-Manager
  • Simple-Timing, the same timing program for use with another company’s results software, which can build a simple event list itself
  • SWIM-Manager, the meet-management program, with entries, seeding, heat sheets, results, entry fees and fines, points scoring, LENEX import and HTML export
  • a certificate program and a layout designer for printed lists

The timing screen lays out the lanes in the order the operator sees the pool. For each lane it shows the touches, the block time at each end, the manual time, the lap time and the total time.2 The software warns the operator, but does not change any time, in four cases:

  • a relay take-off earlier than a set tolerance;
  • a lap that differs too much from the previous one;
  • a touch that has not arrived when it should, which can mean a swimmer turned under the pad;
  • a gap between pad and button times larger than a set limit.

ALGE recommends a relay tolerance of −0.03 s, citing its own and other makers’ tests that put the pad’s take-off time 0.023–0.027 s away from high-speed video. For the pad-and-button gap it recommends 0.30 s, observing that push buttons usually lag the pad by 0.10–0.35 s.5 For training, the system can also take a reaction time when the swimmer’s weight on the block passes 5 kg.5

The SWC can run a heat without the PC. Holding its internal start button for about five seconds reprints every time since the last valid start, and a longer hold, until a double beep, readies it for the next heat.5

Meet-management software

This section covers the system’s links to other results programs. Inside ALGE’s own package, SWIM-Manager reads times from the timing program and can import one lane or a whole heat. ALGE advises keeping the competition file on the timing PC, so that timing carries on if the network fails.5

For other programs, the SWC sends its data out of the printer port. The manual notes that a third-party program reading that port must support the selected printer mode, which prints either run times or times of day.5 Hy-Tek Meet Manager connects with a cable from ALGE to the timer’s Printer 2 port. It collects times in the background and saves a race once the operator presses End, or picks a new race, on the SWIM 2000 PC. The operator then pulls each race in by its event and heat, or by its race number when the heat was entered wrongly on the timer.6

Splash Meet Manager’s release notes record a fix to false-start handling with the SWIM 2000 in September 2007, and a new SWIM 2000 interface that was tested in January 2008 and made the default the next month.14 Splash’s 2011 FAQ lists the SWIM 2000 as a one-way serial interface, and its 2018 brochure still names it.715

Specifications

Figures are for the SWC controller and are from the brochure unless noted.2

SpecificationValue
Measuring range23 h 59 min 59.9999 s
Time reference10.000 MHz TCXO
Accuracy±2.5 ppm from −25 to 50 °C; ±1 ppm a year ageing; adjusted to ±0.1 ppm at 25 °C
LanesUp to 12; up to 10 terminals per bus (2001 web page); 1–10 (Split Second Timing)316
Channels5 per lane per end: touchpad, three push buttons, relay take-off sensor
Interfaces4 × RS232; 3 × RS485
PowerInternal 12 V gel cell; 100–240 V, 50/60 Hz, or 12–18 V DC
Battery running time4 h without the PC
Operating systemWindows 95, 98, ME, NT, 2000, XP (2002); Windows 95, 98, NT 4.0 (2001)1

The sources give different maximum lane counts. The brochure and the 2001 overview page say twelve, the 2001 component page allows ten terminals on each bus, and the page of Split Second Timing, ALGE’s Australian distributor, says one to ten.21316

Installation and safety

This section summarizes ALGE’s architectural guideline for pools fitting the system. ALGE offered two kinds of wiring:8

  • Mobile cable sets, which ALGE describes as the cheapest and safest choice. One person needs about half an hour to lay them, and they can be covered with anti-slip matting during meets.
  • Permanent wiring, which has to be decided early in planning. Every soldered joint has to be sealed with a sealant that does not absorb moisture, because ALGE found that most silicone sealants let the joints corrode within a few years.

For permanent installations ALGE recommended its SO 2 starting block, which has the push-button and touchpad sockets built in. The local contractor was to supply the conduits, the touchpad fasteners and a lift or scaffold for hanging the scoreboard. ALGE’s diagram for a pool used for swimming, water polo, diving and synchronized swimming routes 50 mm PVC conduits, each with a pull wire, between floor boxes, wall boxes and the timing desk.8

The guideline adds 11 mm to the pool length at each end fitted with ALGE touchpads. Pads in a concrete pool hang on brackets set with anchors, so they go in without tools. Pools with a recessed or roll-out gutter need turn plates that stand 300 mm above the water flush with the wall, and ALGE advised that the pool builder make these.8 ALGE also notes that FINA, now World Aquatics, does not approve timing systems as such, contrary to claims by some makers, and states that its own parts conform to the FINA rules.8 The timers overview covers the governing-body requirements that apply to every system.

Part numbers and accessories

This section lists the system’s components that have articles here.25

ItemPart numberArticle
ControllerSWCSWC
Lane terminalSWT; terminator SWT-ENDSWT
TouchpadTP24, TP18TP touchpads
Push button023-02023-02 push button
Starting blockSO 2, SO 2-EX (SO1 on the 2001 page)SO 2
Relay take-off padSWR 2 (SWR1 or SWD1 on the 2001 page)SWR 2
Start unitSU (SWSU on the 2001 page)SU
HeadsetQ34Q34 headset
SpeakersSPA, SPPSPA2 and SPP2
PrinterP5 (P4 on the 2001 page)Printer P5
Display boardGAZ4GAZ4
Cables200-xx, 201-xx, 202-xx, 067-02Swimming cable sets
SoftwareNoneSWIM-Manager

ALGE’s 2001 web pages use several part names that differ from those in its 2002 documents, as the table notes. The 2001 page names the relay pad both SWR1 and SWD1. No source says whether the 2001 names belong to earlier versions of the parts or to the same parts renamed.3

See also

References

Footnotes

  1. ALGE-Timing, SWIM 2000 Timing System for Swimming (archived January 2001). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7

  2. ALGE, SWIM2000 (brochure, 2002; Split Second Timing copy). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15

  3. ALGE-Timing, Components of the SWIM 2000 System (archived January 2001). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7

  4. ALGE-Timing, Produkte (product list; in German; archived October 2000). ↩ ↩2

  5. ALGE-Timing, SWIM2000 Manual (Version E-020222, 2002; archived). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19

  6. Hy-Tek, ALGE SWIM 2000 (Meet Manager guide). ↩ ↩2

  7. Splash Software, Splash Meet Manager 11 FAQ (October 2011). ↩ ↩2

  8. ALGE, SWIM2000 Architectural Guidelines (Version E-02-01-24). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9

  9. ALGE-Timing, Timing Systems for Swimming (archived October 2007). ↩

  10. ALGE-Timing, TM-SWIM TimeManager (product page, as of November 2026). ↩ ↩2

  11. ALGE-Timing, SWIM 2000 technical data (archived January 2001). ↩ ↩2 ↩3

  12. ALGE-Timing, SWIM2000 Bedienungsanleitung (Version D-020222; in German; archived). ↩ ↩2 ↩3

  13. ALGE-Timing, FAQ for SWIM 2000 (archived January 2003). ↩

  14. Splash Software, Release notes (archived June 2010). ↩

  15. Splash Software, Splash Meet Manager (product brochure, April 2018). ↩

  16. Split Second Timing, Swimming (ALGE Australia; undated). ↩ ↩2

Last updated November 8, 2026.