Libre Aquatics Wiki

Daktronics OmniSport Pro Swimming

From Libre Aquatics Wiki, the free aquatics reference

OmniSport Pro Swimming is a Windows program from Daktronics that runs swim races alongside an OmniSport 2000 timing console. It shows each race as the console times it, lets the operator correct lanes and times, stores the results on the computer, and prints and displays them.1 Touchpad, button, relay exchange and reaction times reach meet management software such as Hy-Tek Meet Manager through the console.23 The first release came in October 2002.1 Daktronics no longer sells the program.2

History and versions

This section summarizes the release history in the 2016 manual, which lists 25 versions. Version 1.00 came out on 25 October 2002, followed by three beta releases before the end of that year.1 Several early releases fixed how race data was handed to Hy-Tek Meet Manager. Version 1.17 of November 2003 briefly combined the swimming, diving and synchro programs in a single installer, and the next release split them again.1 Version 1.1.11 of November 2004 added start reaction and relay exchange times, and early 2005 brought German and Traditional Chinese text.1 Version 1.1.18 of January 2007 added team scores and new scoreboard settings. Version 1.2.1 of October 2009 added more lane status warnings and the multicast scoreboard protocol.1

The numbering jumps from 1.2.3, of October 2012, to 3.0.0, of November 2013. Version 3.0.0 added the network link to the console, changed the licensing system, and warns the operator when the two clocks, the computer’s and the console’s, are more than 15 minutes apart.1 The network link matches an OmniSport 2000 firmware release of July 2013, which added communication with the Pro program and with Meet Manager over Ethernet.4 The last version in the manual is 3.0.3, of March 2016.1 Daktronics support refers to a version 4.x as the only one tested on Windows 10. The 2016 manual does not cover that version.51

Role in the timing system

This section places the program between the console, the meet software and the displays. The console does the timing. The HS-200 start system starts its clock. Split and finish times come from touchpads and backup buttons through the lane modules.1 The program connects to the console’s expansion port or network jack and exchanges data in both directions.6 It mirrors the race on screen, and it takes over the console’s race memory. The console holds about 50 races, and when the program connects, every race stored in the console is copied to the computer and erased from the console.6

Meet Manager connects to the console separately. It downloads the event order to the console and asks for times back, naming either the event and heat or the race number. It also sends the start list for the current heat to the Pro program, which uses it for swimmer names and affiliations.32 Results and display data still leave from the console’s own ports, whose formats the program sets.1

Setup and connection

This section covers installation, licensing and the link to the console. The 2016 manual asks for Windows XP or later, a 2.26 GHz processor, 2 GB of memory and Internet Explorer 5.0 or later. It notes that most customers bought the computer from Daktronics.1 The two sources disagree on Windows 8. The manual supports Windows 7 and 8 from version 1.2.2, while Daktronics’ support note asks for version 1.2.3. The support note also says Windows 8.1 is not compatible.15 A trial runs for 30 days. After that the user emails the program’s serial number to Daktronics and receives a license file once the purchase is confirmed; each computer needs its own file.1

The program reaches the console in one of two ways:13

  • serial: a straight-through 9-pin cable from the computer, or a USB-to-serial adapter, to the console’s J4 expansion port, at 38,400 baud
  • network, from version 3.0: the console’s Ethernet jack and the computer both cabled to a router or hub, with the program set to UDP and the port number set automatically

On a network the console’s settings for Pro software and for Meet Manager must both be on, and switching each on disables the matching serial port.3 Up to four consoles can share a network under the names OMNI1 to OMNI4, with default addresses 192.168.0.55 to 192.168.0.58. When the program finds more than one, it asks which to use.31 Daktronics support describes two network faults. If the wireless adapter on the Pro computer or the Meet Manager computer takes priority over the wired one, the program may not reach the console or receive start lists. A UDP port changed by hand also stops the program connecting.789

A status indicator on the main screen shows green when the link works and flashes as data arrives.1 On connection the console sends its event order, which the program offers to save as a file. The console holds 500 events, and the program can keep several such lists for reuse.1 If the program’s settings and the console’s differ, the operator chooses which to keep; the manual recommends the console’s.1

Running a race

This section covers the main screen during a meet. A row for each lane shows whether it is on, how many lengths have been swum, and whether the near and far ends are armed for a split or a finish.1 The operator can switch a lane off, correct its length count after a missed or accidental touch, and re-arm it. Icons warn of an arming delay still counting down, a lane fault, an input firing too often, and a low battery in a relay take-off platform.1 Buttons above the lanes edit the start time, disqualify lanes, arm every lane for a split or a finish, and open the race log.1

The event order supplies the event and heat numbers, the round and the race length. The operator advances them by hand between heats, and changes made here are not written back to the event order file.1 After a race, a store-and-print command saves and prints the results, and a reset clears the clock for the next race, saving the race first if it was not already stored.1 If the console was not reset before a start, the console’s always-ready start feature lets the operator accept the recorded start after resetting. A start time can also be typed in, for example from the printout of a second console run in parallel.1

Four tabs sit below the lanes:1

  • current race: names, affiliations and times for the race in progress, editable, with a disqualification control
  • stored races: earlier races chosen by file, event, heat or date, which can be edited, reprinted, or given a backup time in place of a touchpad time
  • scoreboards: display on or off, time of day, dimming, team scores, and requests for a start list, results or scores on a matrix display
  • test: battery level, lane inputs and scoreboard test patterns, with a mode for testing alone by turning the monitor to face the deck

Configuration

This section covers the settings the program holds, most of which are also console settings.1 The pool settings take the number of lanes (1–10), whether lane order is reversed, whether lanes are numbered 1–10 or 0–9, and a pool length of 25 yards, 25 metres or 50 metres. The timer then works out how many touches each race needs.1 The timer settings cover:1

  • the arming delay that keeps a pad inactive after a touch, usually 15–20 seconds so a relay swimmer can leave the water
  • the flag time, the largest difference allowed between a pad time and a backup time before the result is marked
  • normally open start input for Daktronics horn starts, normally closed for other makes
  • touchpads or buttons as the primary time, near end only or both ends, and hundredths or thousandths
  • relay take-off platforms: none, Daktronics or button type, or Omega, with an arming time of 0.1–1.5 seconds

The program also configures printing, both on the printer built into the console and on the computer’s default printer. Printouts can list finishers in lane or place order, with or without backup times, with cumulative or lap splits, and with relay exchange times, up to ten formats per event.1 An event order editor adds, changes and deletes events and saves the list as a file.1

Scoreboard and data output

This section covers what goes to displays and meet software. For numeric scoreboards the program sets the number of lines, how long splits and finishes hold (1–99 seconds), results in lane or place order, how a disqualification is shown, and whether lap splits and reaction times appear.1 Matrix displays add places on splits and an offset of 5,000, 10,000 or 15,000 for the real-time data, used when two or more pools feed one display.1 The program also chooses the format for each of the console’s outputs:1

  • results port J6, for meet management software: OmniSport 2000, OmniSport 6000 or Colorado Time Systems
  • real-time data port J5: Daktronics real-time data or Colorado Time Systems
  • scoreboard outputs J2 and J3: multidrop, multiline, multicast or Omega

Meet Manager can also act as the source for matrix display content. On request the console fetches team scores, start lists, and heat or event results from it, so the display shows the lane assignments current in the meet software.3

Status

As of 2026, Daktronics lists its ProSwimming interface, with ProDiving and ProSyncro, as discontinued and no longer for sale. It refers customers to its professional services group for newer systems.2 The OmniSport 2000 the program depends on is itself being withdrawn, under an end-of-life plan dated fall 2023.105

See also

References

Footnotes

  1. Daktronics, OmniSport 2000 Pro Swimming Software Installation and Operation Manual (DD3109473 Rev 1, 2016). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34

  2. Daktronics support, Swimming Software. ↩ ↩2 ↩3 ↩4

  3. Daktronics, OmniSport 2000, Pro Swimming and Hy-Tek Software Quick Guide (ED-13876 Rev 5, 19 August 2013). ↩ ↩2 ↩3 ↩4 ↩5 ↩6

  4. Daktronics, All Sport & OmniSport Revision Histories (DD3679410, Rev 06, 5 November 2024), OmniSport 2000. ↩

  5. Daktronics support, DD2485913, OmniSport Pro compatibility with Windows 8, 8.1 and 10. ↩ ↩2 ↩3

  6. Daktronics, OmniSport 2000 Timing Console Operation Manual (ED-13312 Rev 16, 2019). ↩ ↩2

  7. Daktronics support, DD2635125, Pro Swimming will not connect to an Ethernet OmniSport 2000. ↩

  8. Daktronics support, DD3302734, Pro Swim, Hy-Tek alpha data not showing. ↩

  9. Daktronics support, 000011916, OmniSport 2000E will not connect to Pro Swimming. ↩

  10. Daktronics support, 000014371, Wireless judges’ consoles with the OmniSport 2000. ↩

Last updated November 11, 2026.