Libre Aquatics Wiki

ALGE SWT3 swim terminal

From Libre Aquatics Wiki, the free aquatics reference

The SWT3 is the lane terminal of the TM-SWIM swimming timing system made by ALGE-Timing of Lustenau, Austria. One terminal sits at each lane end and takes that lane’s touchpad, up to three backup push buttons and the sensor of its starting block or relay take-off plate. The terminals are chained one to the next on a bus cable back to the TM-SWIM, which also supplies their power.12 All SWT3 units are identical; the TM-SWIM counts and numbers them when it starts up.12 ALGE’s 2017 catalogue calls the SWT3 its latest terminal, and it followed the SWT2 of 2013 and the SWT of the SWIM 2000 system.34

See the deck cabling overview for the shared background that applies to every deck cabling system.

Role in the timing system

The terminal is the junction between the sensors at the pool edge and the timer. Each one has five independent timing channels: one for the touchpad, three for 023-02 push buttons, and one for a starting platform such as the SO5 or a relay pad such as the SWR7.13 Each lane needs one SWT3 at each end where touches are timed, so a pool timed at both ends has two chains, one on the TM-SWIM’s start-side bus and one on its turn-side bus.21

The TM-SWIM manual lets the terminal sit behind its lane or inside an ALGE SO4 or SO5 starting block.1

History and generations

This section covers the three terminal generations. The first, the SWT, served the SWIM 2000 system of the early 2000s, with the same five inputs and the same chained bus ending in an SWT-END.5 ALGE’s 2013 swimming catalogue shows the SWT2 with the TM-SWIM: identical, unnumbered terminals detected and numbered by the timer, with five channels each.4 The SWT3 appears in the 2017 general catalogue and in an April 2017 leaflet, which says the SO5 can measure jump duration “in conjunction with the latest SWT3”.36 ALGE’s product page says an SWT3 must not share a system with the older SWT or SWT2 terminals.7

The TM-SWIM manual of 2024 still tells installers to “connect at least one SWT2” when setting up the software, a line apparently carried over from an earlier edition.1

In December 2024 ALGE’s TM-SWIM firmware history recorded that the terminal hardware had been extended to warn when a touchpad’s resistance drops, reporting the fault as a held pulse on channel 5 and passing it to the PC.8 SwimTime added support for this “SWT-DP touchpad failure pre-warning” in February 2025.9 Whether SWT-DP names a new model or a revision of the SWT3 is not stated.

Design and construction

The SWT3 is a small grey box, about 160 × 85 × 60 mm, which ALGE describes as sealed for use around pools.71 The figures differ slightly between sources: 159 × 84 × 59 mm and 0.3 kg in the manual, 160 × 85 × 60 mm and 577 g on the product page.17 A photo in the manual shows a row of five colour-coded pairs of banana sockets on the front, one blue, three red and one green, and a round screw-lock bus connector at each end.1 The manual says the touchpad input uses a dual-edge trigger system.1

The terminal has no battery or mains input; it takes 12 V from the TM-SWIM along the bus. ALGE gives its timing precision as 1/10,000 s.1

Wiring and installation

All terminals on a side are joined in a chain. Short 200-04 cables link one terminal to the next, a 200-20 cable or a KT200Z10 cable reel links the nearest terminal to the TM-SWIM, and an SWT-END terminator plugs into the last terminal.1 The manual refers to these as the SWCBL cable sets.1 Each ALGE cable has its number printed at both ends, and each device uses a different plug, so cables cannot be connected to the wrong device. The manual asks for the screw-lock connectors to be tightened by hand only, with the force of two fingers.1

Because the terminals carry no number, the TM-SWIM numbers them by their position on the bus. In SwimTime the operator sets which lane is first on the finish bus and on the turn bus, and for ten lanes which numbering scheme applies; the manual warns that a wrong setting assigns times to the wrong lanes.1 When the TM-SWIM is connected, the number of lanes is taken from the hardware. If SwimTime shows fewer lanes than terminals, the manual says to check the cabling and restart the software.1

Testing and troubleshooting

ALGE lists its SWIM-SIM10 lane simulator as an accessory of the SWT3.7 Firmware changes have also touched the terminal side: a 2015 TM-SWIM release reorganised how the timer polls the terminals and fixed an error in its two-edge impulse check.8 Since late 2024 the terminals can flag a touchpad whose resistance is falling before it fails.89

Care and maintenance

The manual recommends wiping the terminal with a dry cloth from time to time and putting a little silicone grease on the contacts to keep them from corroding.1

Specifications

ItemValue
Inputs1 touchpad (dual-edge), 3 push buttons, 1 starting block or relay pad
ConnectorsBanana-socket pairs for the inputs; two screw-lock bus connectors
Power12 V from the TM-SWIM over the bus
Precision1/10,000 s
Dimensions160 × 85 × 60 mm (product page); 159 × 84 × 59 mm (manual)
Weight577 g (product page); 0.3 kg (manual)
HousingSealed for poolside use (ALGE)

Sources: TM-SWIM manual and product page.17

Part numbers and accessories

ItemPart numberNotes
Swim terminalSWT3One per lane per timed end
Bus cable200-04Terminal to terminal
Bus cable200-20, reel KT200Z10First terminal to the TM-SWIM
TerminatorSWT-ENDOn the last terminal
Cable setsSWCBL8S, SWCBL10S, SWCBL10TTerminal cabling for 8 or 10 lanes
SimulatorSWIM-SIM10Tests up to ten lanes

Sources: TM-SWIM manual, product page and cable-set page.17

See also

References

Footnotes

  1. ALGE-Timing, Swimming Timing System (manual, Version E24-08-29), 2, 3.1, 4.5.1.2, 5.1 and 5.5. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19

  2. ALGE-Timing, Aquatic Sports (catalogue, June 2026), pp. 4, 6 and 22. ↩ ↩2 ↩3

  3. ALGE-Timing, General catalogue (2017), pp. 101–102. ↩ ↩2 ↩3

  4. ALGE-Timing, The Specialist for Swimming (catalogue V1.113, 2013), pp. 4–7. ↩ ↩2

  5. ALGE, SWIM2000 (brochure, 2002; Split Second Timing copy). ↩

  6. ALGE-Timing, Starting Block (SO5 and SWR7 leaflet, April 2017). ↩

  7. ALGE-Timing, SWT3 (product page, as of November 2026). ↩ ↩2 ↩3 ↩4 ↩5 ↩6

  8. ALGE-Timing, History file for Time Manager Swim (versions 15.91 to 25.71, 2015–2025). ↩ ↩2 ↩3

  9. ALGE-Timing, History file for SwimTime (version 2.5.2.1, February 2025). ↩ ↩2

Last updated November 8, 2026.