ALGE SWT3 swim terminal
From Libre Aquatics Wiki, the free aquatics reference
The SWT3 is the lane terminal of the TM-SWIM swimming timing system made by ALGE-Timing of Lustenau, Austria. One terminal sits at each lane end and takes that lane’s touchpad, up to three backup push buttons and the sensor of its starting block or relay take-off plate. The terminals are chained one to the next on a bus cable back to the TM-SWIM, which also supplies their power.12 All SWT3 units are identical; the TM-SWIM counts and numbers them when it starts up.12 ALGE’s 2017 catalogue calls the SWT3 its latest terminal, and it followed the SWT2 of 2013 and the SWT of the SWIM 2000 system.34
See the deck cabling overview for the shared background that applies to every deck cabling system.
Role in the timing system¶
The terminal is the junction between the sensors at the pool edge and the timer. Each one has five independent timing channels: one for the touchpad, three for 023-02 push buttons, and one for a starting platform such as the SO5 or a relay pad such as the SWR7.13 Each lane needs one SWT3 at each end where touches are timed, so a pool timed at both ends has two chains, one on the TM-SWIM’s start-side bus and one on its turn-side bus.21
The TM-SWIM manual lets the terminal sit behind its lane or inside an ALGE SO4 or SO5 starting block.1
History and generations¶
This section covers the three terminal generations. The first, the SWT, served the SWIM 2000 system of the early 2000s, with the same five inputs and the same chained bus ending in an SWT-END.5 ALGE’s 2013 swimming catalogue shows the SWT2 with the TM-SWIM: identical, unnumbered terminals detected and numbered by the timer, with five channels each.4 The SWT3 appears in the 2017 general catalogue and in an April 2017 leaflet, which says the SO5 can measure jump duration “in conjunction with the latest SWT3”.36 ALGE’s product page says an SWT3 must not share a system with the older SWT or SWT2 terminals.7
The TM-SWIM manual of 2024 still tells installers to “connect at least one SWT2” when setting up the software, a line apparently carried over from an earlier edition.1
In December 2024 ALGE’s TM-SWIM firmware history recorded that the terminal hardware had been extended to warn when a touchpad’s resistance drops, reporting the fault as a held pulse on channel 5 and passing it to the PC.8 SwimTime added support for this “SWT-DP touchpad failure pre-warning” in February 2025.9 Whether SWT-DP names a new model or a revision of the SWT3 is not stated.
Design and construction¶
The SWT3 is a small grey box, about 160 × 85 × 60 mm, which ALGE describes as sealed for use around pools.71 The figures differ slightly between sources: 159 × 84 × 59 mm and 0.3 kg in the manual, 160 × 85 × 60 mm and 577 g on the product page.17 A photo in the manual shows a row of five colour-coded pairs of banana sockets on the front, one blue, three red and one green, and a round screw-lock bus connector at each end.1 The manual says the touchpad input uses a dual-edge trigger system.1
The terminal has no battery or mains input; it takes 12 V from the TM-SWIM along the bus. ALGE gives its timing precision as 1/10,000 s.1
Wiring and installation¶
All terminals on a side are joined in a chain. Short 200-04 cables link one terminal to the next,
a 200-20 cable or a KT200Z10 cable reel links the nearest terminal to the TM-SWIM, and an
SWT-END terminator plugs into the last terminal.1 The manual refers to
these as the SWCBL cable sets.1 Each ALGE cable has its
number printed at both ends, and each device uses a different plug, so cables cannot be connected to
the wrong device. The manual asks for the screw-lock connectors to be tightened by hand only, with
the force of two fingers.1
Because the terminals carry no number, the TM-SWIM numbers them by their position on the bus. In SwimTime the operator sets which lane is first on the finish bus and on the turn bus, and for ten lanes which numbering scheme applies; the manual warns that a wrong setting assigns times to the wrong lanes.1 When the TM-SWIM is connected, the number of lanes is taken from the hardware. If SwimTime shows fewer lanes than terminals, the manual says to check the cabling and restart the software.1
Testing and troubleshooting¶
ALGE lists its SWIM-SIM10 lane simulator as an accessory of the SWT3.7 Firmware changes have also touched the terminal side: a 2015 TM-SWIM release reorganised how the timer polls the terminals and fixed an error in its two-edge impulse check.8 Since late 2024 the terminals can flag a touchpad whose resistance is falling before it fails.89
Care and maintenance¶
The manual recommends wiping the terminal with a dry cloth from time to time and putting a little silicone grease on the contacts to keep them from corroding.1
Specifications¶
| Item | Value |
|---|---|
| Inputs | 1 touchpad (dual-edge), 3 push buttons, 1 starting block or relay pad |
| Connectors | Banana-socket pairs for the inputs; two screw-lock bus connectors |
| Power | 12 V from the TM-SWIM over the bus |
| Precision | 1/10,000 s |
| Dimensions | 160 × 85 × 60 mm (product page); 159 × 84 × 59 mm (manual) |
| Weight | 577 g (product page); 0.3 kg (manual) |
| Housing | Sealed for poolside use (ALGE) |
Sources: TM-SWIM manual and product page.17
Part numbers and accessories¶
| Item | Part number | Notes |
|---|---|---|
| Swim terminal | SWT3 | One per lane per timed end |
| Bus cable | 200-04 | Terminal to terminal |
| Bus cable | 200-20, reel KT200Z10 | First terminal to the TM-SWIM |
| Terminator | SWT-END | On the last terminal |
| Cable sets | SWCBL8S, SWCBL10S, SWCBL10T | Terminal cabling for 8 or 10 lanes |
| Simulator | SWIM-SIM10 | Tests up to ten lanes |
Sources: TM-SWIM manual, product page and cable-set page.17
See also¶
- ALGE SWT: the first-generation terminal of the SWIM 2000
- ALGE swimming cable sets: the bus cables and terminators
- ALGE TM-SWIM: the timer the terminals connect to
- ALGE SO5 and SWR7: the block and relay pad it reads
- Deck cabling: the deck cabling overview
- ALGE-Timing: the manufacturer
- Equipment: the equipment reference
References¶
Footnotes¶
-
ALGE-Timing, Swimming Timing System (manual, Version E24-08-29), 2, 3.1, 4.5.1.2, 5.1 and 5.5. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19
-
ALGE-Timing, Aquatic Sports (catalogue, June 2026), pp. 4, 6 and 22. ↩ ↩2 ↩3
-
ALGE-Timing, The Specialist for Swimming (catalogue V1.113, 2013), pp. 4–7. ↩ ↩2
-
ALGE, SWIM2000 (brochure, 2002; Split Second Timing copy). ↩
-
ALGE-Timing, Starting Block (SO5 and SWR7 leaflet, April 2017). ↩
-
ALGE-Timing, SWT3 (product page, as of November 2026). ↩ ↩2 ↩3 ↩4 ↩5 ↩6
-
ALGE-Timing, History file for Time Manager Swim (versions 15.91 to 25.71, 2015–2025). ↩ ↩2 ↩3
-
ALGE-Timing, History file for SwimTime (version 2.5.2.1, February 2025). ↩ ↩2
Last updated November 8, 2026.