Libre Aquatics Wiki

Pushbuttons

From Libre Aquatics Wiki, the free aquatics reference

A backup pushbutton is a hand-held button a timer presses at the finish to record a swimmer’s time. Standing behind a lane, the timer holds the button and presses it as the swimmer touches the wall, which sends a stop signal to that lane’s clock on the timing console. The pushbutton is the human-operated backup to the touchpad: the pad records the official time automatically, and the button is an independent check that can stand in when the pad is missed or faults. It is nicknamed a “pickle” for its shape.12

Role in the timing system

The overview of semi-automatic timing systems covers the shared background that applies to every semi-automatic system: the layered primary, secondary, and tertiary timing structure, and the governing-body rules that require independent backup. The button is the usual secondary layer. In fully automatic officiating the buttons wait in reserve behind the pad; in semi-automatic operation the buttons are the timing input, started by the electronic start and stopped by the timer’s press.1 Each lane can carry one, two, or three buttons, designated A, B, and C, each read independently of the pad.3 Because a person reacts to the finish rather than the finish triggering the device, a button time carries the timer’s reaction delay and is treated as a check on the pad, not its equal.4

How button times resolve

How button times become an official time is set by the governing body rather than the hardware. The USA Swimming timing-adjustment rule keeps the pad time as official when the automatic equipment works, and uses the backup button and watch times when a pad malfunction is confirmed.1 The published guidance to that rule states that where three buttons are used and two of the three agree, that time is taken, and that when the backup times differ from the pad time by 0.29 seconds or less the pad time still stands.15 These specific thresholds are USA Swimming’s. Because the procedures and thresholds differ between bodies, a meet follows the rules of its sanctioning organization.

How a lane's official time is settled under USA Swimming rules, flowchart Flowchart. The lane has a pad time. If nothing suggests the pad is wrong, the pad time is official. Three things suggest it may be wrong: the pad and backup times differ by about 0.30 seconds or more, the place judges' finish order disagrees with the times, or the swimmer is reported to have missed the pad or touched it softly. If a malfunction is confirmed, the lane's backup button times are used. With three valid times of which two agree, that time is used; with three that all differ, the middle one; with two, their average with the thousandths dropped; with one, that time unless it conflicts with other information, in which case the administrative official decides. A note adds that a watch time can be used when both the pad and the buttons fail, and that a fault shifting every lane of a heat equally, such as an early start, is corrected across the heat by the average difference instead. The lane has a pad time Any sign the pad time is wrong? • Pad and backup times differ by about 0.30 s or more• Place judges' finish order disagrees• Swimmer missed the pad or touched it softly No Yes, and confirmed The pad timeis official Use the lane's backup button times,counting only valid ones Three times,two agree:that time Three times,all different:the middle one Two times:their average,thousandths dropped One time: that time,unless it conflicts;then the administrativeofficial decides Not on the main path: a watch time can stand in when both the pad and the buttons fail.A fault that shifts every lane in a heat equally, such as an early or late start,is corrected across the heat by the average difference between pad and backup times.
How a lane's official time is settled under USA Swimming rule 102.23.4 when the pad and the backup buttons have both recorded a time. Other governing bodies set their own procedures. The dashed box covers cases outside the main path.

The steps in the flowchart are set out in rule 102.23.4 of the USA Swimming rulebook.6

Products

Colorado Time Systems (CTS) and Daktronics each make the wired backup pushbutton used with their swim-timing systems, and Swiss Timing supplies its OIT3 button with the Quantum harness. This section catalogs these and the other buttons covered; Daktronics states that its buttons and the CTS buttons are cross-compatible, so either can be used on either maker’s lane wiring.7

ProductManufacturerCordConnectionStatus
ALGE-Timing 023-02 push buttonALGE-Timing2 m (023-10: 10 m)Banana plug into a SWT3 terminal or Timy cableCurrent
ALGE-Timing WTN-PB radio push buttonALGE-TimingNoneWTN radioCurrent
Colorado Time Systems PushbuttonColorado Time Systems6 ftBanana plug into deck plate or cable harnessCurrent
Daktronics PushbuttonDaktronicsNot publishedBanana plug into lane module or deck plateSupplied with deck-cabling systems
Superior Swim Timing PushbuttonSuperior Swim TimingNot publishedWaterproof connector or banana plugCurrent
Swiss Timing OIT3 PushbuttonSwiss TimingNot publishedBanana plug into a Quantum harness module or deck plateSupplied with Quantum harness sets
Omega OIT8 PushbuttonOmega Electronics5 mPowerTimeDates not established

Each article covers its button in full, its role in the timing layers, how a timer uses it, how it connects, and its care; this page is the shared overview they refer back to.

See also

References

Footnotes

  1. USA Swimming, Quick Guide to the Timing Adjustment Rule (102.24) (pad time is the official time when the automatic equipment works; primary/secondary/tertiary layers; backup times used on a confirmed malfunction). ↩ ↩2 ↩3 ↩4

  2. Colorado Time Systems, Backup button (PB-6) (the swim timing “pickle”). ↩

  3. Colorado Time Systems, Titanium Deckplate (TDP) (plug-in connections for touchpads and A/B/C backup pushbuttons). ↩

  4. Wikipedia, Aquatic timing system (touchpads as primary timing with backup buttons and stopwatches). ↩

  5. SwimSwam, New USA Swimming Timing Malfunction Rules Take Effect (independent coverage of the primary/secondary/tertiary timing hierarchy). ↩

  6. USA Swimming, 2025 Rulebook, 102.23.4 (determining official time). ↩

  7. Daktronics, Are Daktronics and Colorado Timing System push buttons cross compatible? (KB DD2017009). ↩

Last updated October 1, 2026.