Colorado Time Systems TPM-D test meter
From Libre Aquatics Wiki, the free aquatics reference
The TPM-D is a handheld test meter made by Colorado Time Systems (CTS) for finding faults in a swim timing system. It checks a touchpad or pushbutton on its own, reads the voltage a cable harness or deck plate delivers to a lane, and confirms that a timing console is sending scoreboard data.1 CTS’s System 5 manual already names it in 1998.2 CTS sells it for $375 as of 2026.3
Role in the timing system¶
This section places the meter among the other ways CTS suggests isolating a finish fault.
CTS divides a finish system into three parts: the pad or button, the wiring across or under the deck, and the console itself. Its manuals check them in that order.2 The meter checks the first two. Pads and buttons need nothing else; for the wiring the console must be on, because it supplies the voltage the meter reads.1 The Gen7 guides point to it from their lane status screen. A pad or button that shows as shorted, corroded or closed should be tried on the TPM-D. If it passes there, the deck plate or harness is the next suspect.4 CTS’s 1998 System 5 guide offers an ohmmeter as the alternative for pads and buttons, and a voltmeter for the harness.2
Design and construction¶
This section describes the meter’s panel and connectors.
The meter is a small box with a connector on three sides. Two banana sockets on the top edge, marked TOUCHPAD/BUTTON, take the dual banana plug of a pad or button. The bottom edge, marked DECKPLATE/CABLE HARNESS, carries a pair of banana prongs that plug into the jacks a pad would use. A 1/4 in jack on the left side takes a scoreboard data cable.1 The power button sits between the bottom prongs, so pushing the meter fully into a jack switches it on. For the top sockets it is pressed by hand.1
The face carries a red bar graph marked 3, 4 and 5 volts, a POWER ON lamp and a SCOREBOARD DATA lamp. A legend under the bar graph reads a pressed pad as good at the high end and a released pad as good at the low end.1 The touchpad guides describe a holder on top of the meter for the needle used to adjust a pad’s air.56
The System 5 guide describes readings on a different scale. It treats 0 to 20 as a sound pad at rest, 40 to 50 as defective and anything between as untrustworthy, with a full-scale reading when the pad is touched. It also warns that a weak battery gives false results.2 The 2005 instruction sheet gives no numbers for a pad, only an empty or full bar.1 The sources do not say whether the meter changed between the two documents.
Testing pads and buttons¶
This section covers the test of a single pad or button off the deck.
The pad’s or button’s plug goes into the top sockets and the operator holds the power button. At rest only the power lamp should light. Any lit bar means a shorted pad, one that signals the console without being touched. Pressing the pad face with a fingertip should light the whole bar. A pad that stays dark is open and will not register a touch.1 A pushbutton is read the same way, and CTS says to replace one that gives either wrong reading.1
CTS also uses the meter for the in-water check after installation. Each pad is tried in turn on the meter while a swimmer touches it, before the pads are plugged into the deck.5
Testing harnesses and deck plates¶
This section covers the voltage tests on the wiring that feeds each lane.
For these tests the console is connected and switched on. On a cable harness the meter goes into each pod’s PRIME jack, then its BUTTON jack. On a deck plate, or on an under-block connection hub, it goes into TOUCHPAD, then BUTTON A (RJP), BUTTON B and BUTTON C.1 A healthy jack lights the bar between 4.5 and 5 V. A lower reading points to the console, the harness or plate, or a dirty connector. CTS’s advice is to clean the connector and retest, and to call its support line if the reading stays low.1
The 1998 System 5 guide gives 5 V as the voltage at each harness jack, but 3 V when that console’s low pad voltage option is selected.2 The meter’s instructions do not mention the lower setting, so a console on that setting would read 3 V, below their 4.5 V threshold.1
Checking the scoreboard output¶
This section covers the meter’s one test that does not involve the deck.
The data cable is unplugged from the scoreboard and plugged into the meter’s side jack, with the console set to show running time. A bright yellow SCOREBOARD DATA lamp means data is arriving. If it stays dark or shows a steady red or green, nothing is arriving. CTS says to check that the cable is seated at both ends and that the console is sending running time before calling support.1
Use with the vacuum pump¶
This section covers the meter’s role when a pad’s air is adjusted.
A CTS touchpad’s sensitivity depends on the air sealed inside it, as the touchpads overview explains.5 The adjustment is made out of the water, with the pad plugged into the meter so its state can be watched.76 To cure a shorted pad, a needle pushed into the plug on the pad’s connector block lets air in until the meter’s lamps go out. To cure an open pad, the needle is fitted to a vacuum pump and air is drawn out until the bar is fully lit. Pumping stops there, and the needle comes out five seconds after the lamps begin to go out.76
The sources disagree on which way the bar fills. The pump instructions say the lamps light and go out from right to left.76 The touchpad guide’s in-water check says left to right, which matches the 3 to 5 V scale printed on the panel.51
The 2005 meter sheet names the VP-1 hand pump.1 CTS’s 2011 and 2015 catalogues and its current shop list the TPM-D beside the VP-2 instead.893
Specifications¶
| Manufacturer | Colorado Time Systems, Loveland, Colorado1 |
| Tests | Touchpads, pushbuttons, cable harness pods, deck plates, under-block connection hubs, scoreboard data1 |
| Pad and button input | Dual banana sockets, top edge1 |
| Wiring input | Dual banana prongs, bottom edge, with power button between them1 |
| Scoreboard input | 1/4 in jack, left side1 |
| Display | Red bar graph marked 3–5 V; POWER ON and SCOREBOARD DATA lamps1 |
| Good wiring reading | 4.5–5 V1 |
| Warranty | One year10 |
| Price | $375 (2026)3 |
Part numbers and accessories¶
This section lists the parts the sources name with the meter.
TPM-D, the test meter.32VP-2, the vacuum pump CTS sells beside the meter.36VP-1, the earlier hand pump named in the meter’s instructions.17
See also¶
- CTS cable harness and DP-7 deck plate: wiring the meter tests
- Standard touchpad and AquaGrip touchpad: pads the meter checks
- CTS pushbuttons: buttons the meter checks
- Touchpads: the touchpads overview
- Timers: the timers overview
- Colorado Time Systems: the manufacturer
- Equipment: the equipment reference
References¶
Footnotes¶
-
Colorado Time Systems, Test Meter Instructions (F696 Rev. 0205). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22
-
Colorado Time Systems, Swimming 5 for the System 5 Sports Timer user guide (F506, Rev. 0698), appendix A. ↩ ↩2 ↩3 ↩4 ↩5 ↩6
-
Colorado Time Systems, Test Meter (TPM-D) (shop page). ↩ ↩2 ↩3 ↩4 ↩5
-
Colorado Time Systems, Gen7 Serial Timer User Guide (F1034 Rev 202603), diagnostics. ↩
-
Colorado Time Systems, Standard and AquaGrip Touchpads User Guide (F147) (Rev. 202604). ↩ ↩2 ↩3 ↩4
-
Colorado Time Systems, Using Your Needle/Vacuum Pump (F908 Rev. 200909), VP-2 instructions. ↩ ↩2 ↩3 ↩4 ↩5
-
Colorado Time Systems, Using Your Needle/Vacuum Pump (F207 Rev. 1102), VP-1 instructions. ↩ ↩2 ↩3 ↩4
-
Colorado Time Systems, Complete Timing, Scoring, Training and Display Solutions (2011), touchpad accessories. ↩
-
Colorado Time Systems, Complete Timing, Scoring, Training and Display Solutions (2015), touchpad accessories. ↩
-
Colorado Time Systems, Enhanced Support Options (standard warranty information). ↩
Last updated October 21, 2026.