Colorado Time Systems VP-2 vacuum pump

From Libre Aquatics Wiki, the free aquatics reference

The VP-2 is a hand vacuum pump with a hollow needle, sold by Colorado Time Systems (CTS) for adjusting the air sealed inside a CTS touchpad. It draws air out of a pad that will not register a touch; the needle on its own lets air into a pad that signals without one.1 The pad’s state is watched on a TPM-D test meter during the adjustment, and the needle is kept in a holder on top of that meter.12 The earliest VP-2 instructions found date from August 2006.3 As of 2026, CTS sells the pump for $165.4

Role in the timing system

This section places the pump among CTS’s touchpad maintenance tools.

A CTS touchpad closes its switch by air pressure, and the amount of air in the pad sets how hard a touch must be. The touchpads overview covers that background. CTS’s touchpad manual names two tools for keeping pads in adjustment, the test meter and the “vacuum pump and needle”.2 Its architectural guidelines describe the pair the same way: the meter shows whether a pad responds correctly, and the pump changes its air.5 CTS sells both as separate accessories,67 and the touchpad systems for its Gen7 serial timer include one of each.8

The manual expects most pads to need adjusting once, after installation. Pads that pass that first check should then need no further adjustment.2

Design and construction

This section describes the pump in the two forms CTS has documented.

The pump is worked with one hand. Squeezing the handle toward the grip and letting it spring back makes one stroke.1 A length of clear plastic hose runs from the pump, and the needle fits on its free end. The needle has a cover, and between uses it is stored in a receptacle on top of the test meter rather than with the pump.1

The 2006 instructions show a white pistol-grip pump with two ports. The vacuum port is on the front and the pressure port is on top, and the operator moves the hose to the front port if it has been left on the top one.3 The 2009 revision shows a different grey pump with a single hose fitting at the front and a vacuum/pressure switch on the side of its head. The operator checks that the switch is set to vacuum before use.1 The brand name Mityvac is moulded into the grip of the pump in the 2009 photographs, so the pump is a Mityvac unit sold under the CTS part number. CTS’s text does not name the maker or the model.1

Adding and releasing air

This section covers the two adjustments the pump and needle are used for.

The pad is always out of the water for either adjustment. Its plug goes into the test meter, and the rubber plug in the pad’s connector block, which is orange, has to be dry, because water drawn into the pad destroys it.1 CTS also warns against holding a pad by its cable while working on it. The needle is deburred first if its tip is rough, by drawing it across stone or concrete while turning it.1

A shorted pad has too little air and signals the timer without being touched. To let air in, the operator pushes the bare needle, with no pump attached, fully into the middle of the orange plug without forcing it. The needle stays in until the meter’s lamps go out, and comes out three seconds later.1

An open pad has too much air and does not signal when touched. For this the needle goes on the pump hose and into the plug, and the operator pumps until the meter’s bar is fully lit, which shows that the pad’s switch has closed. Pumping then stops. The needle stays in until the lamps begin to go out, and comes out five seconds after that.1 It is then covered and returned to the meter.1

The sources disagree on which way the meter’s lamps travel. The pump instructions, and the same procedure as reprinted in the touchpad manual, say right to left.12 The manual’s own in-water check says the bar fills left to right, which matches the volt scale printed on the meter.29

CTS describes the pump as adding air as well as removing it.45 None of its procedures uses the pump’s pressure side. Air is added with the needle alone, and the 2009 procedure only sets the switch to vacuum.12

Diagnosis

This section covers how CTS’s manual decides which adjustment a pad needs.

The touchpad manual’s troubleshooting table combines the meter reading with how the pad’s face feels under the fingers. CTS compares a correctly filled pad to a thick magazine and an overfilled one to foam rubber.2

Pad feelsMeterCTS’s readingAction
FirmFull bar when touched, dark at restCorrectNone
SpongyFull bar when touched, dark at restToo much airNone while it works; evacuate if it floats or grows less sensitive
FirmLit at restToo little air (excess vacuum)Vent with the needle

Source: CTS touchpad manual, troubleshooting guide.2

The same table lists why an evacuation might fail to cure an open pad. The causes are a pad that was not vented after it was evacuated, a pump hose on the wrong air inlet, water in the vacuum hose, or a broken wire in the pad’s cable.2 For a pad that shorts during a meet, when there is no time for the meter, the manual allows a quick fix. The plug is towelled dry and the needle left in it for ten seconds. CTS warns that this can damage the pad and that the pad should be tested properly after the meet.2

Compared with the VP-1

This section sets out how the VP-2 differs from the pump CTS documented before it.

The VP-1 was a T-handle plunger pump. It was held with a moulded arrow pointing up and worked with full, even strokes, and its vacuum hose was the one on the port below the arrow. CTS’s VP-1 sheet asks for a few drops of oil in a hole on top to keep the action smooth.10 The VP-2 is squeezed rather than pushed and pulled. Its needle has a cover, and from 2009 a switch selects vacuum in place of choosing the right port.31 The steps at the pad are the same for both pumps.101

CTS’s test meter sheet of February 2005 still names the VP-1.9 The first VP-2 sheet is dated August 2006, and the 2008, 2011 and 2015 catalogues and the current shop list only the VP-2.3111274 No CTS document says the VP-2 replaced the VP-1; that is inferred from these dates.

Documentation

This section lists the revisions of the VP-2 instructions.

RevisionDatePump shown
F908 Rev.0806August 2006White pump, separate vacuum and pressure ports3
F908 Rev.200909September 2009Grey Mityvac pump with vacuum/pressure switch1

The 2009 procedure is also reprinted as a chapter of the CTS touchpad manual, in both its 2014 and 2026 editions.132

Specifications

ManufacturerColorado Time Systems, Loveland, Colorado1
Pump makerMityvac (brand moulded on the 2009 pump)1
OperationOne-hand squeeze handle1
Mode selectionVacuum/pressure switch (2009); separate ports (2006)13
Connection to the padNeedle through the orange plug on the connector block, via clear hose1
Used withTPM-D test meter12
Price$165 (2026)4

Part numbers and accessories

This section lists the parts the sources name with the pump.

  • VP-2, the vacuum pump.47
  • TPM-D, the test meter used with it, which holds the needle.71
  • VP-1, the earlier plunger pump.910
  • TP-GEN7-6, TP-GEN7-8 and TP-GEN7-10, the Gen7 serial touchpad systems that include a meter and vacuum pump.8

See also

References

Footnotes

  1. Colorado Time Systems, Using Your Needle/Vacuum Pump (F908 Rev.200909). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23

  2. Colorado Time Systems, Standard and AquaGrip Touchpads User Guide (F147) (Rev. 202604). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12

  3. Colorado Time Systems, Using Your Needle/Vacuum Pump (F908 Rev.0806). ↩ ↩2 ↩3 ↩4 ↩5 ↩6

  4. Colorado Time Systems, Vacuum pump (VP-2) (shop page). ↩ ↩2 ↩3 ↩4 ↩5

  5. Colorado Time Systems, Architectural Guidelines: A Guide for Designing Competitive Aquatic Facilities, touchpad accessories. ↩ ↩2

  6. Colorado Time Systems, AquaGrip Touchpads (datasheet accessory list). ↩

  7. Colorado Time Systems, Complete Timing, Scoring, Training and Display Solutions (2015), touchpad accessories. ↩ ↩2 ↩3 ↩4

  8. Colorado Time Systems, Gen7 Serial Swim Timing datasheet, touchpad systems. ↩ ↩2

  9. Colorado Time Systems, Test Meter Instructions (F696 Rev. 0205). ↩ ↩2 ↩3

  10. Colorado Time Systems, Using Your Needle/Vacuum Pump (F207 Rev.1102), VP-1. ↩ ↩2 ↩3

  11. Colorado Time Systems, Making Time Count (2008 catalogue), touchpad accessories. ↩

  12. Colorado Time Systems, Complete Timing, Scoring, Training and Display Solutions (2011), touchpad accessories. ↩

  13. Colorado Time Systems, Touchpads User Guide (F147, Rev. 201407, July 2014), the earlier edition of the same manual. ↩

Last updated October 23, 2026.