TOP-8
From Libre Aquatics Wiki, the free aquatics reference
TOP-8 is a timing program for the PowerTime and PowerTime II hand-held timers, first published by Omega Electronics and later by Swiss Timing. It covers athletics and swimming. In lane mode it takes one finish per lane for up to eight lanes, each from a judge’s pushbutton; in non-lane mode one judge records every finisher on a single line and the operator adds bib numbers afterwards.1 The timer prints every finish, can drive a scoreboard, and sends results to a PC, where Hy-Tek Meet Manager and Splash Meet Manager can read them.123
History and versions¶
This section traces the program’s versions through Omega’s download page and the manuals.
TOP-8 began as an Omega Electronics program for the original PowerTime, distributed on a floppy program disk and loaded into the timer from a PC.4 In April 2002 Omega’s download page listed version 2.0 as current. Its new feature let the operator rearm every lane after the finishes so that each lap could be timed, and the matching user manual was then at version 1.1.4 By the page’s update of July 2002 it listed version 3.0, with results shown page by page on the scoreboard and automatic bib numbering in non-lane mode. It also recorded a version 2.1 that fixed the serial settings at 9600 baud, no parity, 8 data bits and 1 stop bit, so that Splash or Meet Manager could connect.5 From December 2002 Omega offered version 2.0 of the user manual, document 3361-511-02, which describes the same two modes.67
Swiss Timing carried the program over to the PowerTime II. Its manual, document 3462.511, is at
version 3.2 in both the English (.02) and French (.01) editions; the French file dates from
February 2010.18 The manuals disagree on when two options arrived. Omega’s manual
says the scoreboard page time and the non-lane settings need version 3.0 or later, and Omega’s
2002 download page lists them under 3.0; both Swiss Timing editions say 3.2.7518
The dated Omega page supports 3.0.
Role in the timing system¶
This section places TOP-8 among the equipment it works with.
TOP-8 is one of several programs for the PowerTime family. The operator chooses which to load, and Swiss Timing’s installer copies it from a PC over the timer’s serial cable.9 Other programs offered for the timers include Standard and Ski on both models, Dual on the original, and Swim Training on the PowerTime II, which is meant for practice rather than races.410
For a swimming race the timer takes its start from a start system or its own START/STOP key and
its finishes from judges’ pushbuttons. The pushbuttons plug into the
PowerTime swimming harness
(3361.611), which joins the timer’s extension socket; athletics uses a nine-input box
(3361.609) instead.19 The manuals list the
OIT3 pushbutton on a 3 m
coiled cable (2872.003), and Omega’s edition adds the
OIT8 on a 5 m cable
(2872.008).78 None of the TOP-8 manuals mentions touchpads; the inputs
they describe are pushbuttons, and a photocell for athletics.17
Setting up a race¶
This section covers the steps before the start in both modes.
Most settings are shared with the timer’s other programs and are described in the general manual: contact types, an arming delay of 0–99 s, resolution from 1/1000 s to 1 s, the rounding rule, the printer, and the scoreboard format.91 TOP-8 adds a few of its own, covered in the scoreboard section below.
Each race opens on a selection screen. The operator sets the event and heat, each from 0 to 199, moving between the two with the arrow keys, and confirms with ENTER. The choice is printed, and the race screen replaces the selection screen.1 The start input is now armed. The ON/OFF key takes it out of the armed state if needed.1
Lane mode¶
This section describes the mode used for races in lanes, such as a 100 m.
The race screen shows the event and heat, a status mark for each of the eight lanes, the start status, the running time and a cursor.1 When the start arrives the clock runs on the display and the cursor drops to lane 1. Each lane shows an X while the arming delay runs; once the delay ends the X becomes a dash and the lane will accept a finish.1
A press on a lane’s input records that lane’s finish. The printer logs the time of day and the race time, and the display shows the lane’s time and place, with the lane’s number replacing the dash in the status line.1 During the race the number keys act on the lanes:
| Key | Effect |
|---|---|
| 1–8 | Move the cursor to that lane |
| 0 | Disarm every lane |
| 9 | Rearm every lane and discard their times |
Once every lane has a time, one press of ESC offers three choices: return to the race, send the results out, or clear the race. A second press of ESC goes back to the selection screen with the heat number already advanced by one.1
Non-lane mode¶
This section describes the mode for one finish line and one judge, such as a marathon or a 1500 m.
The operator picks the event and heat as in lane mode. After the start the clock runs, the cursor sits on the first result line, and the screen shows the place the next finisher will take.1 Each impulse on the armed stop input is stored, shown and printed as a time of day. The operator then types the bib number for the time under the cursor and presses ENTER; the printer adds a line with the bib and time of day, followed by that competitor’s race time.1
The ON/OFF key arms and disarms the finish line during the race. Swiss Timing suggests disarming it while no competitor is due, so that a photocell on the line does not record other people crossing it.1 From version 3.0 (3.2 in Swiss Timing’s manual) two settings apply to this mode: whether each finish is numbered automatically, and whether the running time stays on the scoreboard after the first finisher.15
Corrections¶
This section covers the two faults the manual describes and how each is repaired.
If a judge presses by mistake after the start, the operator keys that lane’s number and then the correction key. The bottom line of the display asks “?clear”; ENTER deletes the lane’s time and arms it again, and ESC leaves it unchanged.1
If a judge presses twice and the second press is the true finish, TOP-8 has already used the first as the official time. The second press is kept in the store of received impulses. From the correction key the operator opens the CORRECTION screen, chooses the buffer, and scrolls through the stored times of day until the right one appears, then confirms it with ENTER. The timer recalculates the lane’s race time, and the printer records the change marked as a correction.1 The PowerTime II also marks every corrected or hand-entered time with an asterisk on the printout.9 In non-lane mode the same correction screen applies.1
Scoreboard and data output¶
This section covers the program’s scoreboard settings and how results reach a computer.
The PowerTime II has a scoreboard line and a separate RS-232 PC line, which runs at 9600 baud, 8 data bits, 1 stop bit and no parity.9 TOP-8 offers two scoreboard types:
- RollerTime, which Swiss Timing calls its standard scoreboard protocol.
- Multiline, which shows up to eight lanes at once on numeric boards. Swiss Timing’s manual gives its GEMINI board as the example, Omega’s manual the UNT6, and the PowerTime II general manual the Calypso.179
Where the board has fewer than eight lines, a page time setting cycles through the results one page at a time and sets how long each page stays up.1 A “dh run time” setting, when on, sends the running time to the PC output as well as to the board.1
Equipment from other makers also takes PowerTime output. Daktronics drew the address settings for its SW-2000 lane displays to take a PowerTime in July 1999, and its All Sport 5000 controller reads PowerTime data through a Venus 7000 computer, with the timer set to a one-line multiline board.1112 Swiss Timing lists its Piccolo swimming board for use with a PowerTime running TOP-8.13
Results go to a PC through the send-results choice at the end of a race.1 In 2002 Omega also offered a description of the PC output so that users could write their own data-handling programs.4
Meet-management software¶
This section lists the meet programs documented to read TOP-8 results.
Hy-Tek Meet Manager treats the PowerTime as a timing console. It uses an RS-232 cable with a phone-jack plug at the timer and a 9-pin plug at the computer. After each race the operator chooses PC under send results on the timer, Meet Manager stores the data as it arrives, and the operator fetches each race’s times when ready.2 Only finish times transfer, not splits. Hy-Tek warns that TOP-8 version 2.0 will not work and points users to a later version.2 Omega’s note that version 2.1 fixed the serial settings for Splash and Meet Manager is the likely reason.5 Meet Manager’s open water module can also download times from the timer.14
Splash Meet Manager lists the Swiss Timing PowerTime among its timing interfaces, over a one-way serial link.3 Neither program’s guide names the PowerTime model or the TOP-8 version it was tested with.
See also¶
- PowerTime II: the current timer that runs it
- PowerTime: the original Omega timer
- Swim Training: the PowerTime II’s training program
- PowerTime swimming harness: the eight-lane pushbutton harness
- Software: the software overview
- Swiss Timing: the publisher
References¶
Footnotes¶
-
Swiss Timing, User Manual TOP-8 (3462.511.02, version 3.2). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24
-
Splash Software, Splash Meet Manager 11 FAQ (October 2011). ↩ ↩2
-
Omega Electronics, Sports downloads: Power Time (April 2002, archived). ↩ ↩2 ↩3 ↩4
-
Omega Electronics, Sports downloads: Power Time (July 2002, archived). ↩ ↩2 ↩3 ↩4
-
Omega Electronics, Sports downloads: Power Time (December 2002, archived). ↩
-
Omega Electronics, User Manual TOP-8 (3361-511-02, version 2.0) (ManualZilla copy). ↩ ↩2 ↩3 ↩4 ↩5
-
Swiss Timing, Mode d’emploi TOP-8 (3462.511.01, version 3.2) (French, 2010). ↩ ↩2 ↩3
-
Swiss Timing, PowerTime II General User’s Manual (3462.501.02, version 1.0). ↩ ↩2 ↩3 ↩4 ↩5 ↩6
-
Swiss Timing, Instruction manuals, PowerTime II. ↩
-
Daktronics, SW-2000 Series 10” Numeric Digit Display Manual (ED-12156, Rev 14, May 2015), drawing A-118395. ↩
-
Daktronics, All Sport 5000 Series Control Console Operation Manual (ED-11976, Rev 32, November 2024), track. ↩
-
Swiss Timing, Omega Piccolo White swimming scoreboard datasheet (10-2015). ↩
-
Hy-Tek, Meet Manager 6 guide, Omega Power Time open water download. ↩
Last updated November 16, 2026.