SwimTime
From Libre Aquatics Wiki, the free aquatics reference
SwimTime is the Windows program from ALGE-Timing that operates the TM-SWIM swim timing console. It shows the lanes and times, holds the event list, and passes results to meet-management software, while the console does the timing.12 ALGE distributes it as freeware.2
Naming and versions¶
ALGE changed the version scheme in February 2013. The numbers now stand for the year, the month and the version within the month, so 2.5.4.1 is a release of April 2025. It is the current release as of November 2026.34 The published history file begins with that change, and earlier versions are not listed.3
The program comes in ten languages: Dutch, English, Finnish, French, German, Hungarian, Italian, Norwegian, Russian and Spanish.4 There are help files in all of these except Dutch and Hungarian.2
History¶
ALGE’s earlier SWIM 2000 system had its own software package. The TM-SWIM, on ALGE’s website by December 2007, replaced that system’s SWC controller.5 According to its help file, SwimTime was made for both controllers; with an SWC the user has to choose the serial port.2 Its first release is not documented. Splash Software added a SwimTime interface to its meet manager in April 2010, and reaction times to that interface a month later.6
The history file records these additions:3
| Date | Version | Addition |
|---|---|---|
| June 2013 | 1.3.6.1 | Omega Calypso display boards |
| December 2014 | 1.4.12.1 | Colorado display boards |
| June 2015 | 1.5.6.1 | Starts from the turn end for events such as 150 m |
| September 2017 | 1.7.9.1 | Check for new versions |
| September 2018 | 1.8.9.2 | Timy timers over USB |
| November 2018 | 1.8.11.2 | Automatic use of manual times |
| May 2022 | 2.2.5.1 | 1650 m event; distances up to 25 km |
| March 2023 | 2.3.3.1 | Time-trial rounds from Lenex |
| February 2025 | 2.5.2.1 | Team points for the United States; touchpad failure warning |
| March 2025 | 2.5.3.1 | Record lists; non-binary athletes |
| April 2025 | 2.5.4.1 | Hy-Tek record files |
Role in the timing system¶
The race runs in the console. ALGE’s 2013 and 2017 catalogues say that once the events are loaded the computer is needed only to follow and control the race. They also describe timing on one computer and meet management on others.17 The help file gives the capacity as 32 lanes timed at one end or 16 at both, depending on the console’s firmware.2 The TM-SWIM article covers the console and its lane equipment.
SwimTime can also run without any meet-management program. The operator then types in the events and heats, and names are optional.2
Requirements and installation¶
The product page lists Windows 7 to 11. The help file installed with the same version still lists Windows XP, 2003 and Vista as well. The help also reports that the program ran under Wine on Linux with a serial connection, without support.42
ALGE’s manual has the software installed before the console is first connected, so that the USB driver is in place.8 The help warns that a firewall must not block the program, because it talks to the meet computer and to network displays.2
Meets and events¶
A SwimTime database holds one or more meets. Each meet is divided into sessions, events and heats, and the
session carries the pool length, which must agree with the hardware settings.2 ALGE recommends
a new database for every competition.8 The records dialog holds three lists, chosen by the
user, and records can be read from Splash, from Lenex files or from Hy-Tek .rec files.23
The history file limits a race to 400 touches, a figure first recorded in October 2016 and repeated in May 2022.3
Running a heat¶
Each lane is drawn in the order of the pool, with its time, touches and manual time. A click turns a lane on or off, and a menu on the lane edits the swimmer, the touch count, the status or the times.2 The status may be OK, DSQ, DNF or DNS. A manual time can be put in place of the touchpad time, and the change reversed.2 Edited times carry a source code that shows whether they came from a touchpad, a button, a starting block, the start, or a correction.2
Warnings come from two checks. A manual time turns red when it differs too much from the touchpad time, and a touch warning appears when a manual time has no pad time or when a lap takes about twice as long as the one before.2 The operator ends the heat with End Heat, which can also send the results. A registry setting ends it automatically when the last swimmer finishes; ALGE leaves this off and warns that it leaves no time for changes.2
Timing settings¶
Times are computed at 1/10,000 s and cut to the output precision, which is 1/100 s as supplied.28 The limit times block touchpads after the start and after a touch, and a separate value sets how early a relay swimmer may leave.2 The TM-SWIM article lists the block times and warning values.
Descriptions of the Take manual automatic option disagree. The manual says it uses the button time if the two times differ by more than a preset value, 0.500 s. The help says it fills in a missing touchpad time, with the preset as a waiting period, and that it does not work while a lap warning is showing. The option is off by default.82
Two-edge timing uses the press of a pad for the time and its release for statistics. One topic in the help requires SWT2 terminals for it and another requires the SWT3.2
Displays and video¶
Numeric ALGE boards connect to the console, and SwimTime offers seven display modes for them, by lane or by rank. It can also show reaction and relay times, and team points for American college meets.2 An intermission dialog shows a result, the time of day or chosen text between races. For a victory ceremony it can show the first three only.2
Boards from other makers connect to the PC by serial adapter: Omega Calypso boards through USB-RS485 and Colorado boards through USB-RS232.8 The D-RTNM matrix boards are reached by network address, in three sizes.2
A network display output sends the running data to one computer or to the whole network. PC Display Multisport, ALGE’s program for video walls, uses it.2 IDCam video units are set up in the same dialog, up to 32 of them, each covering one or more lanes.2
Meet-management software¶
The help lists five compatible programs: Splash Meet Manager, SPORTSYSTEMS, WinGrodan, Hy-Tek Meet Manager and Euroconsult Orpheus.2 EasyWk also has an ALGE interface.9
Splash and Lenex¶
SwimTime and Splash exchange text files, splash_send.txt and splash_receive.txt, in a shared
folder.10 The Swim Wiki places the files beside SwimTime.exe. ALGE’s manual shows a folder
under the public documents, and its help recommends leaving the folder on the timing computer so that
timing can go on if the network fails.1082 The options import
new data from Splash and send a heat’s status at End Heat.2 SPORTSYSTEMS 5.3 and later uses
the same folder.2
Lenex files can be imported. Version 3.0 is fully supported and 2.0 in part. The help says Lenex export has not been built.2
Hy-Tek¶
Hy-Tek data arrives in two files: the event schedule, generic.sch, and then the scoreboard start list,
startlist.slx, which needs Hy-Tek’s scoreboard license. The schedule has no names and no heat
counts.2 SwimTime writes a result file for each heat, by hand or at every End Heat. The Standard
format serves pools of up to 10 lanes, and Format version 2 is for larger ones.2 The
generic network file sharing article covers the Hy-Tek side.
WinGrodan¶
A WinGrodan start list in text form can be imported, and WinGrodan can also be wired to the console.2 Its maker has since renamed the program Swimify.11
Timy support¶
Since September 2018 SwimTime has read a Timy over USB, in the Timy’s PC Timer, Backup, Tracktimer and SwimTrainer programs.3 This works only in automatic mode. SwimTime sets the Timy’s start number from the event and heat, two digits each, except in SwimTrainer.3
Printing¶
Results go to the console’s log printer or to a Windows printer. The menu prints the current heat on the log printer, the whole event, or a protocol of the heat with statistics.28 The report layouts can be edited, which the help says ALGE does not support.2
Licensing and availability¶
SwimTime is free to download from ALGE’s website, and it is also supplied on a USB stick with the system.48 The 2013 catalogue offered ten years of free updates and the 2017 and 2026 ones offer free updates without a term.1712 The help menu also installs new firmware on the console, with different files for the SWC and the TM-SWIM.2
See also¶
- ALGE SWIM-Manager: the software of the earlier SWIM 2000 system
- PC Display Multisport: ALGE’s video-wall software
- TM-SWIM: the console it operates
- Splash Meet Manager and Hy-Tek Meet Manager: meet-management programs it exchanges data with
- SST timing software: another maker’s timing program
- Software: the software overview
- ALGE-Timing: the publisher
References¶
Footnotes¶
-
ALGE-Timing, The Specialist for Swimming (catalogue V1.113, 2013), pp. 6–7. ↩ ↩2 ↩3
-
ALGE-Timing, SwimTime help (English help file installed with version 2.5.4.1, April 2025). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34 ↩35
-
ALGE-Timing, History file for SwimTime (versions 1.3.2.1 to 2.5.4.1, 2013–2025). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7
-
ALGE-Timing, TM-SWIM TimeManager (product page with downloads, as of November 2026). ↩ ↩2 ↩3 ↩4
-
ALGE-Timing, TimeManager TM-SWIM (archived December 2007). ↩
-
Splash Software, Release notes (builds 7735 and 8195; archived June 2010). ↩
-
ALGE-Timing, Swimming Timing System Manual (Version E24-08-29), 3 and 4. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8
-
EasyWk, EasyWk (product page, in German). ↩
-
ALGE-Timing, Aquatic Sports (catalogue, June 2026), p. 7. ↩
Last updated November 24, 2026.