The Quantum Mobile Harness is the on-deck lane cabling that Swiss Timing makes for its Quantum Aquatics timer. It is a chain of small modules, one per lane, into which each lane’s touchpad, starting block and pushbuttons plug. One cable runs from the chain to the timer and carries both power and data.12 Each module stores a lane number, so the timer identifies a lane by the module’s address rather than by the wire the signal arrives on.34 Swiss Timing sells it in Primary sets for a single timer and Primary & Secondary sets for a pair of timers, in 6-, 8- and 10-lane sizes.1 The general background on on-deck harnesses and in-deck plates is on the deck cabling overview.

Role in the timing system

The harness is the mobile half of Quantum’s lane cabling. A pool with permanent wiring instead has a deck plate at each lane, cabled back to an ODB10-SW distribution box in the timing room. The box holds the fixed-installation equivalent of the harness modules and connects to the same timer inputs.56 The mobile harness needs no construction work. It is laid along the deck before a session and packed away afterwards.

Swiss Timing’s cabling diagrams place one harness at each pool end that has touchpads. The finish-end harness goes into the timer’s HA1 input and the harness at the far end of a 25 m or 50 m course into HA2. The start systems connect separately to START1 and START2.2 The ODB10-SW manual labels its racks the same way, HA1 for the finish and HA2 for the 50 m end.5

Design and construction

Each module is a red case, 105 × 105 × 36 mm, printed with its lane number. It has a 3 m lead that plugs into the next module towards the timer.17 The top face carries banana sockets, colour-coded by device:1

Socket colourDevice
YellowOCP5 touchpad
WhiteOSB11 starting block, which carries the relay break detection
RedOIT pushbutton (up to three per lane)

Sockets linked by a printed white line are the common return and are joined inside the case. A lane can also be run on three pushbuttons alone, without a touchpad.1

Swiss Timing’s 2017 swimming concept manual pictures a different module. It shows a flat red bar with two rows of sockets and its cable leaving one end, and gives its size as 125 × 35 × 105 mm with a 3 m cable.6 The 2013 datasheet and the 2019 harness manual both give 105 × 105 × 36 mm and show the square, numbered case. The documents do not say whether the concept manual shows a different version of the module or an unrelated drawing.71

Primary and Primary & Secondary modules

Quantum comes in a Primary version with one timer and a Primary & Secondary version that contains two complete timers and a data switch for choosing which one’s results are used.2 The harness comes in matching versions:

  • A Primary module sends five contacts to the timer: the touchpad, the relay break detection from the block, and three buttons.2
  • A Primary & Secondary module does the same job but adds a second electronic circuit, so each contact reaches both timers. It sends ten contacts in all, and it is the heavier of the two at 0.865 kg against 0.760 kg.12

Both versions still use one cable per pool end. Each harness input on the timer is a 7-pin Tuchel socket. A Primary & Secondary timer carries a +12 V supply and a differential data pair for each circuit on it, plus a shared ground. The Primary timer wires only the primary pins.2 The harness takes its power from the timer. The Quantum datasheet puts the timer’s typical draw at 0.55 A for a Primary unit with no harness modules connected, rising to 1.00 A with 24 modules. For a Primary & Secondary unit the figures are 1.1 A and 2.0 A.8

Lane addressing

Swiss Timing programs each module’s lane number at the factory, and the number printed on the case shows which lane it is set to.1 Replacing a module on site uses the Programmer AQ, a hand-held RFID unit. It reads or writes the lane number when held within 1 cm of the antenna mark on the module.3 Writing a Primary module needs only the programmer. A Primary & Secondary module holds two circuits, so it must be cabled to a Quantum while it is written. The operator deselects the HA1 harness in the timing software, writes one circuit, reselects the harness and writes the other, then checks in the software that the module appears in the right lane.3 The Programmer AQ also writes the lane numbers of the ODB10-SW’s harness circuits.3

The stored number is a module address, and the software decides which pool lane each address stands for. In the pool configuration screen the operator marks which ends have a harness and on which input. They also mark which devices are fitted at each module, and match module numbers to lanes. Swiss Timing’s example uses modules 3 and 5 as lanes 1 and 2 so that two swimmers can race in the central lanes.4 The timer polls the chain and reports every module it finds. During a race each lane number on screen is green while the timer is talking to that lane’s module, orange while it is trying, and red if the module cannot be found. A single control disconnects every harness module and blocks incoming timing pulses until it is reconnected.4

Chaining and connection to the timer

Each module’s lead ends in a male 7-pin Tuchel plug, which goes into the female socket of the module before it in the chain. Up to ten modules chain at each pool end. The last module takes a terminator plug, part number 3480.770, which comes with each set.17

A 25 m Quantum harness cable (1892.025) from the first module to the timer is supplied as standard.1 For longer runs the harness manual lists 50 m and 75 m cables on drums (1892.050 and 1892.075). The Quantum Concept manual instead lists the 50 m cable and a 100 m one (1892.100) on winders, and does not mention the 75 m length.12 Neither document says whether the 100 m cable replaced the 75 m one.

Care and maintenance

After each use Swiss Timing asks for the modules to be wiped with a damp cloth, using water without additives. The banana sockets are then filled with silicone paste, Rhodorsil B431, part number 9038.7047.1 According to the Quantum software manual, cleaning and regreasing should happen weekly as well as after every use.4 The modules are stored clean and dry, between −10 and 60 °C, and are rated for use between 0 and 45 °C.1

Specifications

SpecificationValue
Lane numbers0–9, set at the factory, rewritable with the Programmer AQ
Modules per pool endUp to 10
Contacts per module5 (Primary); 10 (Primary & Secondary)
Device socketsBanana: yellow touchpad, white starting block, red pushbuttons
Chain connectorTuchel 7-pin, male plug into the previous module’s female socket
Module size105 × 105 × 36 mm, plus 3 m cable
Module weight0.760 kg (Primary); 0.865 kg (Primary & Secondary)
Cable to timer25 m standard; 50, 75 or 100 m on drums (see text)
PowerFrom the timer over the harness cable (+12 V per circuit)
Operating temperature0–45 °C
Storage temperature−10–60 °C

Part numbers and accessories

  • 3480.950, 3480.958, 3480.956: Primary harness sets for 10, 8 and 6 lanes.1
  • 3480.960, 3480.968, 3480.966: Primary & Secondary harness sets for 10, 8 and 6 lanes.1
  • 3480.750–3480.759: Primary modules for lanes 0–9; 3480.760–3480.769: Primary & Secondary modules for lanes 0–9. The 6-lane sets contain lanes 1–6, the 8-lane sets lanes 1–8, and the 10-lane sets lanes 0–9.7
  • Spare modules, at most two per harness: the harness manual numbers them 3480.75X (Primary) and 3480.76X (Primary & Secondary), while the 2013 datasheet lists them as 3480.923 and 3480.924.17
  • 3480.921, 3480.922: Programmer AQ sets, each with a Primary or a Primary & Secondary module.1
  • 3480.770: Quantum harness terminator, one per set.7
  • 1892.025, 1892.050, 1892.075, 1892.100: Quantum harness cables, 25 m to 100 m.12
  • 2872.003: OIT3 pushbutton, one per lane in each set.7
  • 9038.7047: Rhodorsil silicone paste, 100 g, for the sockets.7
  • 9072.6005: transport case.7

See also

References

Footnotes

  1. Swiss Timing, Quantum Mobile Harness User’s Manual (3480.500.02, v1.1, August 2019). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18

  2. Swiss Timing, Quantum Concept Swimming User’s Manual (3480.508.02, v1.4, July 2015). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8

  3. Swiss Timing, Programmer AQ User’s Manual (3480.501.02, v1.1, January 2019). ↩ ↩2 ↩3 ↩4

  4. Swiss Timing, Quantum-Swimming User’s Manual (3480.509.02, v1.4, October 2019). ↩ ↩2 ↩3 ↩4

  5. Swiss Timing, ODB10-SW User’s Manual (3494.501.02, v1.7, December 2018). ↩ ↩2

  6. Swiss Timing, Swimming Concept: Quantum / OSB with footrest (0017.509.02, v4.9, January 2017), 3.4.3 Harness. ↩ ↩2

  7. Swiss Timing, Aquatics Harness Swimming Pool datasheet (HARNESS_3480_1303) (2013; kit contents). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9

  8. Swiss Timing, Quantum Aquatics datasheet (Quantum AQ/10-2015). ↩

Last updated October 9, 2026.