Libre Aquatics Wiki

Omega OCP5 touchpad

From Libre Aquatics Wiki, the free aquatics reference

The OCP5 is the touchpad sold under the Omega name by Swiss Timing. It is a stainless steel frame carrying a row of interlinked PVC slats, behind which tape-switch contact strips close when a swimmer presses the face.12 The model name appears in Omega advertising by 1976, and the same name covers the four sizes in Swiss Timing’s 2015 manual and datasheet.312 Only the largest size, 240 × 90 cm, meets the World Aquatics minimum for a touch panel, and Swiss Timing marks it as the FINA model.14

Role in the timing system

This section places the OCP5 in an Omega installation; the general background on touchpads is on the touchpads overview.

The pad hangs on the end wall of each lane and signals the timer when a swimmer finishes or turns. In a current Swiss Timing installation it plugs into the yellow socket of a lane module on the Quantum Mobile Harness, or into an in-deck plate wired to an ODB10-SW box, and from there into a Quantum Aquatics timer.56 Earlier Omega pads worked with the OSM-5 and OSM6 consoles.37

History

This section traces the pad from Omega’s early advertising to the current Swiss Timing product.

Omega was advertising its swimming touchpads in the United States by 1973. Its exclusive North American representative then said the pads had been in use since 1965 and did not leak, corrode, warp or dent.8 Omega’s own history gives 1967 as the year it introduced touchpads.9 The touchpads overview covers the conflicting dates for touch panels at the Games of that decade.

The OCP-5 name first appears in late 1975 and January 1976, in advertisements for Omega’s OSM-5, a portable printing timer sold as a complete touchpad system. Six-, eight- and ten-lane packages cost $5,500, $6,300 and $7,800 and included OCP-5 pads measuring 5 ft by 2 ft, with “standard sized” Omega pads of 6 ft 6 in by 2 ft as an option.103 Omega’s advertising in 1977 and 1978 argued that the pad was what set the system apart, because age-group swimmers touch more lightly than older ones.11 In 1979 Omega described the OCP-5 as a lightweight PVC pad of patented design that could be repaired on site and had seen Olympic use.12

In 1985 Omega’s US agent announced that FINA had allowed the equipment used at the 1984 Games, OCP5 pads included, to be called “FINA Approved”.7 An equipment survey in 1991 described the OCP5 as light and durable, responsive to even the lightest touch from a young swimmer and unaffected by wave action.13

Omega patented two touch-pad designs in this period. The first, filed in 1971 with Swiss priority from 1970, used a single perforated plastic plate.14 The second, filed in 1976 by Omega’s parent company SSIH, replaced the plate with separate hollow extruded panels hooked to one another so that each could move a little on its own, over contact cables running across them.15 That second construction is the one the OCP5 manual describes, and the 1979 advertisement’s “patented design” fits it, but no source names the patent and the product together.15112

The current manual was first issued in 2010 and revised to version 3.1 in February 2015.1 Its repair instructions still distinguish “old touchpads”, whose slats hook together and whose contact strips are glued in place, from current ones.1

Design and construction

This section describes how the pad is built.

The frame is high-grade stainless steel. The face is made of individual PVC slats, linked side by side and held at the top by a plastic sheath and snap-in fasteners. Yellow, black and two-tone slats are available, and a set of yellow slats printed “Swiss Timing” can be fitted to the 90 cm sizes.12 Behind the slats, two or three tape-switch contact strips run across the pad inside guide channels and protective sheaths, and are soldered in parallel to the single cable. Polarity does not matter.1

Swiss Timing says the pad is unaffected by hard water and chemical corrosion, and that it can be repaired by the owner on site without being sent back.12

Contact operation and sensitivity

This section covers what makes the pad register a touch.

Pressure on any point of the face pushes a slat against the contact strips and closes them, and the timer records the closure at once. A broad, even change in pressure, such as a wave, does not close the strips, which is how the pad avoids false signals from wash.12

Swiss Timing’s documents give three figures for the force needed:129

SourceTrigger force
OCP5 manual, introduction2–3 kg of localised pressure
OCP5 manual, sensitivity test1.5–3.5 kp, measured with the supplied dynamometer
OCP5 datasheetAbout 2 kg
Omega’s swimming history page1.5–2.5 kg

The test range is the most specific of these figures, because it is the value an installer measures with the dynamometer.1 Sensitivity can be reduced zone by zone by mounting a contact strip the other way round, so that its large and small ribs swap places; Swiss Timing recommends leaving the strips in their standard orientation.1

Models and dimensions

This section lists the four current sizes.

Size (cm)Part numberLengthHeightWeightMounting
240 × 90, FINA2924.0032403 mm905 mm16.3 kgAngle brackets or direct to the wall
190 × 902924.0051908 mm905 mm12.8 kgAngle brackets or direct to the wall
200 × 602924.0012003 mm605 mm10.2 kgHung from the gutter wall
150 × 602924.0001503 mm605 mm7.3 kgHung from the gutter wall

Dimensions and weights are from the 2015 datasheet, which also gives the lane spacing each size suits; part numbers and mounting are from the manual.21 The datasheet labels the smallest size “150/160” in its kit table, where the manual calls it 150 × 60 throughout.21 Six-, eight- and ten-lane kits add a force gauge, a pad tester, fixings and spare parts.2

The 1976 pad was smaller than any current size, at 5 ft by 2 ft (about 152 × 61 cm), with 6 ft 6 in by 2 ft pads as the larger option.3

Mounting

This section covers fixing the pad to the end wall.

The 60 cm pads hang from the gutter wall on angle brackets adjusted to the wall’s thickness and locked with a special nut. Swiss Timing uses this mounting for lanes narrower than 2.0 m.12 The 90 cm pads either sit on angle brackets fixed into 8 mm holes 65 mm deep, or are screwed straight to the wall through 6 mm holes 45 mm deep; either way the pad must lie flat against the wall.1 Swiss Timing’s installation guide sets the starting block 410 mm back from the pool edge when an OCP5 is fitted, instead of the usual 400 mm.6

Connection to the timer

This section covers how the pad’s signal reaches the timer.

Each pad has one cable ending in a dual banana plug.15 On a Quantum installation it goes into the yellow socket of the lane’s harness module or deck plate; the white and red sockets beside it take the starting block and pushbuttons.56

Care and maintenance

This section summarises Swiss Timing’s care, test and repair instructions.

Swiss Timing advises taking pads out of the pool between sessions. After use they are rinsed with fresh water, stood upright to drain, wiped, and left to dry for longer than they were in the water. They are stored upright, on Swiss Timing’s trolley where available, and never laid flat or stacked, which can damage the contact strips.116

Before a meet, a buzzer on the pad’s cable checks the pad. It should stay silent with no load, and should sound when the dynamometer presses the middle of a slat at and below the water line. The last check is a simulated touch into the timer.1 A buzzer that sounds with no load points to a convex pool wall, a bent strip or channel, debris behind a slat, or slats that have come apart.1

Repairs are done on site. A contact strip that reads above 50 Ω when closed has oxidised electrodes; one that reads around 100 kΩ when open has probably let water in. Either way the strip is replaced. Single slats can also be swapped.1

Specifications

This section gives Swiss Timing’s published figures.

ItemValue
FrameStainless steel1
FaceInterlinked PVC slats, yellow, black or two-tone1
ContactsTwo or three tape switches, wired in parallel1
Trigger force1.5–3.5 kp test range; 2–3 kg or about 2 kg stated elsewhere12
Sizes240 × 90, 190 × 90, 200 × 60, 150 × 60 cm12
Weight7.3–16.3 kg2
ConnectionSingle cable, dual banana plug15
MountingGutter brackets (60 cm); angle brackets or direct fixing (90 cm)1

Part numbers and accessories

This section lists the parts named in Swiss Timing’s documents.

PartNumber
Touchpads, 150 × 60, 200 × 60, 190 × 90, 240 × 90 (FINA)2924.000, 2924.001, 2924.005, 2924.0031
Cable2924.6671
Slats, yellow and black (60 cm; 90 cm)2924.155, 2924.157; 2924.154, 2924.1561
Two-tone slat; set of 12 “Swiss Timing” slats (90 cm)2924.158; 2924.6381
Buzzer tester2924.6311
Dynamometer2924.6321
Maintenance material (60 cm; 90 cm)2924.621; 2924.6221
Gutter angle brackets; special nut2924.626; 2924.0981
Storage trolley, up to ten pads2924.90312
Protective cover for stored pads2924.9042

See also

References

Footnotes

  1. Swiss Timing, Touchpad OCP5 User’s Manual (2924.510.02, version 3.1, February 2015). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34 ↩35 ↩36 ↩37 ↩38

  2. Swiss Timing, Omega OCP5 Touchpad datasheet (OCP5-Touchpad/10-2015). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15

  3. Seagull Enterprises, “Omega delivers the OSM-5”, advertisement with system prices, Swimming World, January 1976. ↩ ↩2 ↩3 ↩4

  4. World Aquatics, Facilities Rules 2021–2025, FR 2.3.4 touch panels. ↩

  5. Swiss Timing, Quantum Mobile Harness User’s Manual (3480.500.02, v1.1, August 2019). ↩ ↩2 ↩3 ↩4

  6. Swiss Timing, Swimming Concept: Quantum / OSB with footrest (0017.509.02, v4.9, January 2017). ↩ ↩2 ↩3

  7. Swimming World, November 1985, news item on FINA approval of Omega’s 1984 Games equipment. ↩ ↩2

  8. Seagull Enterprises, “It’s the touchpad that stops the clock”, Omega advertisement, Swimming World, November 1973. ↩

  9. Omega, Swimming (touchpads introduced 1967; 1.5–2.5 kg). ↩ ↩2

  10. Seagull Enterprises, “Omega delivers the OSM-5”, advertisement, Swimming World, October 1975. ↩

  11. Omega, OSM-5 advertisement with a coach’s testimonial, Swimming World, August 1977. ↩

  12. Omega Electronic Timing, advertisement (OSM-5 and OCP-5 touchpad), Swimming World, November 1979. ↩ ↩2

  13. Swimming World, August 1991, timing equipment survey, Omega entry. ↩

  14. US Patent 3,745,275, Touch pad for swimming competitions (Omega; filed 1971, granted 1973). ↩

  15. US Patent 4,117,283, Swimming pool touch pad construction (SSIH; filed 1976, granted 1978). ↩ ↩2

  16. Swiss Timing, Quantum-Swimming User’s Manual (3480.509.02, version 1.4, October 2019), maintenance. ↩