Swiss Timing Programmer AQ
From Libre Aquatics Wiki, the free aquatics reference
The Programmer AQ is a hand-held radio-frequency identification (RFID) tool made by Swiss Timing. It reads and rewrites the lane number stored in the lane hardware of the Quantum Aquatics timer: the modules of the Quantum Mobile Harness and the harness circuits inside an ODB10-SW distribution box.1 Swiss Timing sets these lane numbers at the factory, so the programmer is needed only when a module or circuit is replaced on site.23 Its manual was first issued in January 2012.1
Role in the timing system¶
Quantum identifies a lane by an address stored in the lane’s hardware, not by the wire a signal arrives on. Each mobile harness module, and each harness circuit in a fixed installation, holds one lane number, and the timing software maps those numbers to pool lanes.24 A new module or circuit fitted as a replacement has to carry the number of the lane it is replacing. Swiss Timing’s harness manual and datasheet both point to an optional programmer for that case.25 The Programmer AQ reads and writes the stored number over a short-range radio link.1
Background on mobile harnesses and in-deck lane wiring is on the deck cabling overview.
Design and construction¶
The programmer is a small battery-powered case with a display and six keys: a power key, an Enter key and four arrow keys.1 At power-up the display shows the unit’s name and version, and the main menu shows a battery gauge in its top corner.1 Two AA cells sit in a compartment on the back, under a cover released by a lever. The case measures 168 × 74.4 × 35 mm and weighs 0.150 kg, or 0.200 kg with cells fitted.1 Swiss Timing’s 2013 harness datasheet pictures the programmer beside two harness modules.5
Operation¶
The main menu has four entries, stepped through with the up and down keys and opened with Enter:1
| Menu entry | Function |
|---|---|
| Turn OFF | Switches the programmer off |
| Read ADD | Reads the lane number held in a module or circuit |
| Write ADD | Writes a chosen lane number to a module or circuit |
| Read vers. | Reads the version of the harness circuit in a module or ODB10-SW |
The unit also turns itself off after one minute without a key press.1
To read or write, the operator holds the programmer against the target. The manual repeats on every procedure page that the gap must be 1 cm or less. An ODB10-SW harness circuit is read by passing the programmer over the circuit card. A mobile harness module is read through an antenna symbol printed on the side of its case.1 A read shows the stored lane number on the display. For a write, the operator picks the lane number with the arrow keys before holding the programmer to the target, and the display shows OK when the write succeeds.1 After writing a mobile harness module, the manual asks the operator to confirm in the timing software that the module now appears in the intended lane.1
Primary & Secondary modules¶
A Primary & Secondary harness module carries two circuits, one for each timer of a Primary & Secondary Quantum pair.2 Writing one is a longer procedure. The module has to be cabled to the Quantum through both harness inputs, HA1 and HA2. The operator first deselects the HA1 harness in the swimming software so that the HA2 side can be written.1 On the programmer, the lane number is chosen and then marked with a star (the right key, then the up key) before it is written. The harness is then selected again in the software, the lane is checked there, and the whole write is repeated without the star.1 The manual does not name which circuit receives each write. The 2019 revision of the manual changed only the deselection step.1
The ODB10-SW programmer¶
The ODB10-SW manual names its own programmer for harness circuits, part number 3494.901,
supplied with a spare circuit.3 The Programmer AQ manual covers ODB10-SW circuits
directly, but neither manual says whether 3494.901 is the same hand-held unit sold under a
different set number, and no other source found settles it.13
Care and maintenance¶
The programmer is kept clean and dry when not in use. Swiss Timing rates it for use between 0 and 45 °C and for storage between −10 and 60 °C.1
Specifications¶
| Specification | Value |
|---|---|
| Type | Hand-held RFID programmer |
| Targets | Quantum Mobile Harness modules (Primary, Primary & Secondary); ODB10-SW harness circuits |
| Functions | Read lane number, write lane number, read circuit version |
| Range | 1 cm maximum |
| Keys | Power, Enter, four arrows |
| Power | 2 × AA (UM-3) 1.5 V cells |
| Auto power-off | After 1 minute idle |
| Dimensions | 168 × 74.4 × 35 mm |
| Weight | 0.150 kg without cells; 0.200 kg with |
| Operating temperature | 0–45 °C |
| Storage temperature | −10–60 °C |
Part numbers and accessories¶
3480.921: programmer set with a Primary mobile harness module.153480.922: programmer set with a Primary & Secondary mobile harness module.153494.901: programmer for ODB10-SW harness circuits, supplied with a spare circuit; possibly the same unit (see above).3
The first edition of the harness manual (December 2011) refers readers to the programmer manual
as 3480.502.02. The 2019 edition gives 3480.501.02, the number printed on the programmer
manual itself.2
See also¶
- Quantum Mobile Harness: the mobile lane modules it programs
- ODB10-SW: the fixed-wiring box whose circuits it programs
- Quantum Aquatics: the timer the lane hardware serves
- Deck cabling: the deck-cabling overview
- Swiss Timing: the manufacturer
References¶
Footnotes¶
-
Swiss Timing, Programmer AQ User’s Manual (3480.501.02, v1.1, January 2019). ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18
-
Swiss Timing, Quantum Mobile Harness User’s Manual (3480.500.02, v1.1, August 2019). ↩ ↩2 ↩3 ↩4 ↩5
-
Swiss Timing, ODB10-SW User’s Manual (3494.501.02, v1.7, December 2018), 3.2. ↩ ↩2 ↩3 ↩4
-
Swiss Timing, Quantum-Swimming User’s Manual (3480.509.02, v1.4, October 2019). ↩
-
Swiss Timing, Aquatics Harness Swimming Pool datasheet (HARNESS_3480_1303) (2013). ↩ ↩2 ↩3 ↩4
Last updated October 7, 2026.